32 changes: 26 additions & 6 deletions source/_integrations/modbus.markdown
Original file line number Diff line number Diff line change
Expand Up @@ -614,11 +614,36 @@ climates:
description: "Holding register."
input:
description: "Input register."
scale:
description: "Scale factor (`output` = `scale` * `value` + offset) for setting target and current temperature. Cannot be used together with `current_temp_scale` or `target_temp_scale."
required: false
type: float
default: 1
offset:
description: "Final offset for current temperature (output = scale * value + offset)."
description: "Final offset for target and current temperature (`output` = `scale` * `value` + `offset). Cannot be used together with current_temp_offset or target_temp_offset`."
required: false
type: float
default: 0
current_temp_scale:
description: "Scale factor for current temperature (output = `current_temp_scale` * `value` + `current_temp_offset`). Cannot be used together with `scale`"
required: false
type: float
default: 1.0
current_temp_offset:
description: "Offset for current temperature (output` = current_temp_scale` * `value` + `current_temp_offset`). Cannot be used together with *offset*."
required: false
type: float
default: 0.0
target_temp_scale:
description: "Scale factor for target temperature (`output` = `target_temp_scale` * `value` + `target_temp_offset`). Cannot be used together with scale`."
required: false
type: float
default: 1.0
target_temp_offset:
description: "Offset for target temperature (`output` = `target_temp_scale` * `value` + `target_temp_offset`). Cannot be used together with offset`."
required: false
type: float
default: 0.0
target_temp_register:
description: "Register address for target temperature (Setpoint). Using a list, it is possible to define one register for each of the available HVAC Modes. The list has to have a fixed size of 7 registers corresponding to the 7 available HVAC Modes, as follows: Register **1: HVAC AUTO mode**; Register **2: HVAC Cool mode**; Register **3: HVAC Dry mode**; Register **4: HVAC Fan only mode**; Register **5: HVAC Heat mode**; Register **6: HVAC Heat Cool mode**; Register **7: HVAC OFF mode**. It is possible to set duplicated values for the modes where the devices don't have a related register."
required: true
Expand All @@ -628,11 +653,6 @@ climates:
required: false
type: boolean
default: false
scale:
description: "Scale factor (output = scale * value + offset) for setting target temperature."
required: false
type: float
default: 1
structure:
description: "If `data_type: custom` is specified a double-quoted Python struct is expected,
to format the string to unpack the value. See Python documentation for details.