Skip to content
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
3 changes: 3 additions & 0 deletions homeassistant/components/homematicip_cloud/sensor.py
Original file line number Diff line number Diff line change
Expand Up @@ -14,6 +14,7 @@
AsyncPassageDetector,
AsyncPlugableSwitchMeasuring,
AsyncPresenceDetectorIndoor,
AsyncRoomControlDeviceAnalog,
AsyncTemperatureHumiditySensorDisplay,
AsyncTemperatureHumiditySensorOutdoor,
AsyncTemperatureHumiditySensorWithoutDisplay,
Expand Down Expand Up @@ -79,6 +80,8 @@ async def async_setup_entry(
):
entities.append(HomematicipTemperatureSensor(hap, device))
entities.append(HomematicipHumiditySensor(hap, device))
elif isinstance(device, (AsyncRoomControlDeviceAnalog,)):
entities.append(HomematicipTemperatureSensor(hap, device))
if isinstance(
device,
(
Expand Down
9 changes: 9 additions & 0 deletions tests/components/homematicip_cloud/test_device.py
Original file line number Diff line number Diff line change
Expand Up @@ -15,6 +15,15 @@
)


async def test_hmip_load_all_supported_devices(hass, default_mock_hap_factory):
"""Ensure that all supported devices could be loaded."""
mock_hap = await default_mock_hap_factory.async_get_mock_hap(
test_devices=None, test_groups=None
)

assert len(mock_hap.hmip_device_by_entity_id) == 182


async def test_hmip_remove_device(hass, default_mock_hap_factory):
"""Test Remove of hmip device."""
entity_id = "light.treppe"
Expand Down
25 changes: 25 additions & 0 deletions tests/components/homematicip_cloud/test_sensor.py
Original file line number Diff line number Diff line change
Expand Up @@ -165,6 +165,31 @@ async def test_hmip_temperature_sensor2(hass, default_mock_hap_factory):
assert ha_state.attributes[ATTR_TEMPERATURE_OFFSET] == 10


async def test_hmip_temperature_sensor3(hass, default_mock_hap_factory):
"""Test HomematicipTemperatureSensor."""
entity_id = "sensor.raumbediengerat_analog_temperature"
entity_name = "Raumbediengerät Analog Temperature"
device_model = "ALPHA-IP-RBGa"
mock_hap = await default_mock_hap_factory.async_get_mock_hap(
test_devices=["Raumbediengerät Analog"]
)

ha_state, hmip_device = get_and_check_entity_basics(
hass, mock_hap, entity_id, entity_name, device_model
)

assert ha_state.state == "23.3"
assert ha_state.attributes[ATTR_UNIT_OF_MEASUREMENT] == TEMP_CELSIUS
await async_manipulate_test_data(hass, hmip_device, "actualTemperature", 23.5)
ha_state = hass.states.get(entity_id)
assert ha_state.state == "23.5"

assert not ha_state.attributes.get(ATTR_TEMPERATURE_OFFSET)
await async_manipulate_test_data(hass, hmip_device, "temperatureOffset", 10)
ha_state = hass.states.get(entity_id)
assert ha_state.attributes[ATTR_TEMPERATURE_OFFSET] == 10


async def test_hmip_power_sensor(hass, default_mock_hap_factory):
"""Test HomematicipPowerSensor."""
entity_id = "sensor.flur_oben_power"
Expand Down
197 changes: 197 additions & 0 deletions tests/fixtures/homematicip_cloud.json
Original file line number Diff line number Diff line change
Expand Up @@ -14,6 +14,203 @@
}
},
"devices": {
"3014F711000BBBB000000000": {
"availableFirmwareVersion": "2.0.2",
"firmwareVersion": "2.0.2",
"firmwareVersionInteger": 131074,
"functionalChannels": {
"0": {
"coProFaulty": false,
"coProRestartNeeded": false,
"coProUpdateFailure": false,
"configPending": false,
"deviceId": "3014F711000BBBB000000000",
"deviceOverheated": false,
"deviceOverloaded": false,
"deviceUndervoltage": false,
"dutyCycle": false,
"functionalChannelType": "DEVICE_OPERATIONLOCK",
"groupIndex": 0,
"groups": [],
"index": 0,
"label": "",
"lowBat": false,
"operationLockActive": false,
"routerModuleEnabled": false,
"routerModuleSupported": false,
"rssiDeviceValue": -45,
"rssiPeerValue": -54,
"supportedOptionalFeatures": {
"IFeatureDeviceCoProError": false,
"IFeatureDeviceCoProRestart": false,
"IFeatureDeviceCoProUpdate": false,
"IFeatureDeviceOverheated": false,
"IFeatureDeviceOverloaded": false,
"IFeatureDeviceTemperatureOutOfRange": false,
"IFeatureDeviceUndervoltage": false
},
"temperatureOutOfRange": false,
"unreach": false
},
"1": {
"actualTemperature": 23.0,
"deviceId": "3014F711000BBBB000000000",
"display": "ACTUAL",
"functionalChannelType": "WALL_MOUNTED_THERMOSTAT_PRO_CHANNEL",
"groupIndex": 1,
"groups": [],
"humidity": 52,
"index": 1,
"label": "",
"setPointTemperature": 20.0,
"temperatureOffset": 0.0,
"vaporAmount": 10.662700840292974
}
},
"homeId": "00000000-0000-0000-0000-000000000001",
"id": "3014F711000BBBB000000000",
"label": "Raumbedienger\u00e4t",
"lastStatusUpdate": 1579383507353,
"liveUpdateState": "LIVE_UPDATE_NOT_SUPPORTED",
"manufacturerCode": 1,
"modelId": 282,
"modelType": "ALPHA-IP-RBG",
"oem": "M\u00f6hlenhoff",
"permanentlyReachable": true,
"serializedGlobalTradeItemNumber": "3014F711000BBBB000000000",
"type": "ROOM_CONTROL_DEVICE",
"updateState": "UP_TO_DATE"
},
"3014F711000000BBBB000005": {
"availableFirmwareVersion": "1.0.16",
"firmwareVersion": "1.0.12",
"firmwareVersionInteger": 65548,
"functionalChannels": {
"0": {
"coProFaulty": false,
"coProRestartNeeded": false,
"coProUpdateFailure": false,
"configPending": false,
"deviceId": "3014F711000000BBBB000005",
"deviceOverheated": false,
"deviceOverloaded": false,
"deviceUndervoltage": false,
"dutyCycle": false,
"functionalChannelType": "DEVICE_BASE",
"groupIndex": 0,
"groups": [],
"index": 0,
"label": "",
"lowBat": false,
"routerModuleEnabled": false,
"routerModuleSupported": false,
"rssiDeviceValue": -41,
"rssiPeerValue": -29,
"supportedOptionalFeatures": {
"IFeatureDeviceCoProError": false,
"IFeatureDeviceCoProRestart": false,
"IFeatureDeviceCoProUpdate": false,
"IFeatureDeviceOverheated": false,
"IFeatureDeviceOverloaded": false,
"IFeatureDeviceTemperatureOutOfRange": false,
"IFeatureDeviceUndervoltage": false
},
"temperatureOutOfRange": false,
"unreach": false
},
"1": {
"actualTemperature": 23.3,
"deviceId": "3014F711000000BBBB000005",
"functionalChannelType": "ANALOG_ROOM_CONTROL_CHANNEL",
"groupIndex": 1,
"groups": [],
"index": 1,
"label": "",
"setPointTemperature": 23.0,
"temperatureOffset": 0.0
}
},
"homeId": "00000000-0000-0000-0000-000000000001",
"id": "3014F711000000BBBB000005",
"label": "Raumbedienger\u00e4t Analog",
"lastStatusUpdate": 1579384126279,
"liveUpdateState": "LIVE_UPDATE_NOT_SUPPORTED",
"manufacturerCode": 1,
"modelId": 281,
"modelType": "ALPHA-IP-RBGa",
"oem": "M\u00f6hlenhoff",
"permanentlyReachable": true,
"serializedGlobalTradeItemNumber": "3014F711000000BBBB000005",
"type": "ROOM_CONTROL_DEVICE_ANALOG",
"updateState": "TRANSFERING_UPDATE"
},
"3014F711000000000000AAA5": {
"availableFirmwareVersion": "0.0.0",
"firmwareVersion": "1.0.12",
"firmwareVersionInteger": 65548,
"functionalChannels": {
"0": {
"coProFaulty": false,
"coProRestartNeeded": false,
"coProUpdateFailure": false,
"configPending": false,
"deviceId": "3014F711000000000000AAA5",
"deviceOverheated": false,
"deviceOverloaded": false,
"deviceUndervoltage": false,
"dutyCycle": false,
"functionalChannelType": "DEVICE_OPERATIONLOCK",
"groupIndex": 0,
"groups": [],
"index": 0,
"label": "",
"lowBat": false,
"operationLockActive": false,
"routerModuleEnabled": false,
"routerModuleSupported": false,
"rssiDeviceValue": -58,
"rssiPeerValue": -59,
"supportedOptionalFeatures": {
"IFeatureDeviceCoProError": false,
"IFeatureDeviceCoProRestart": false,
"IFeatureDeviceCoProUpdate": false,
"IFeatureDeviceOverheated": false,
"IFeatureDeviceOverloaded": false,
"IFeatureDeviceTemperatureOutOfRange": false,
"IFeatureDeviceUndervoltage": false
},
"temperatureOutOfRange": false,
"unreach": false
},
"1": {
"actualTemperature": 16.0,
"deviceId": "3014F711000000000000AAA5",
"display": "ACTUAL",
"functionalChannelType": "WALL_MOUNTED_THERMOSTAT_PRO_CHANNEL",
"groupIndex": 1,
"groups": [],
"humidity": 42,
"index": 1,
"label": "",
"setPointTemperature": 12.0,
"temperatureOffset": 0.0,
"vaporAmount": 5.710127947243264
}
},
"homeId": "00000000-0000-0000-0000-000000000001",
"id": "3014F711000000000000AAA5",
"label": "Thermostat Schlafen Tal",
"lastStatusUpdate": 1578954498192,
"liveUpdateState": "UP_TO_DATE",
"manufacturerCode": 1,
"modelId": 408,
"modelType": "HmIP-WTH-B",
"oem": "eQ-3",
"permanentlyReachable": true,
"serializedGlobalTradeItemNumber": "3014F711000000000000AAA5",
"type": "WALL_MOUNTED_THERMOSTAT_BASIC_HUMIDITY",
"updateState": "BACKGROUND_UPDATE_NOT_SUPPORTED"
},
"3014F7110000000000ABCD50": {
"availableFirmwareVersion": "1.0.12",
"firmwareVersion": "1.0.12",
Expand Down