Notifications
You must be signed in to change notification settings - Fork 37.4k
Add support for Stiebel Eltron heat pumps #21199
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Merged
Merged
Changes from all commits
Commits
Show all changes
26 commits
Select commit
Hold shift + click to select a range
4da30c1
Start with Stiebel Eltron heatpump
fucm 01899c1
STE HP
fucm acc79c2
Add read of operating mode
fucm 3c5eb0a
Add read-write operation mode
fucm 70a55ae
Further extract ModBus access
fucm ee36a4a
Separation of platform and API
fucm 31799e3
Last changes
fucm a4d3a66
Use modbus hub
fucm fa4eb5b
Update module doc with config
fucm 8292e4f
Clean up platform code
fucm 2977654
Cleanup and update to dev2 of pystiebeleltron
fucm b5c3ac3
Remove slave configuration
fucm f373dc2
Add translation of states
fucm 7876ed3
Make name parameter optional
fucm 8c69f4e
Consolidate platform
fucm 90f15f2
Correct .coveragerc after conflict
fucm 7a91dc1
Prepare component for sensor platform
fucm 6ba3a30
Fix issues found in review
fucm 1746799
Remove custom states and map to existing HA states
fucm 9cd13ab
Force update, when values are modified
fucm 0b7361c
Update CODEOWNERS and requirements_all.txt
fucm 94400be
Fix .coveragerc file
fucm 8ad6dcb
Exclude stiebel_eltron components in .coveragerc
fucm aaa5e23
Break out to module level constant
fucm 13d737c
Rename constant
fucm 99e284f
Removed REQ and DEP constant.
fucm File filter
Filter by extension
Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
There are no files selected for viewing
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
| Original file line number | Diff line number | Diff line change |
|---|---|---|
| @@ -0,0 +1,59 @@ | ||
| """The component for STIEBEL ELTRON heat pumps with ISGWeb Modbus module.""" | ||
| from datetime import timedelta | ||
| import logging | ||
|
|
||
| import voluptuous as vol | ||
|
|
||
| from homeassistant.components.modbus import ( | ||
| CONF_HUB, DEFAULT_HUB, DOMAIN as MODBUS_DOMAIN) | ||
| from homeassistant.const import CONF_NAME, DEVICE_DEFAULT_NAME | ||
| from homeassistant.helpers import discovery | ||
| import homeassistant.helpers.config_validation as cv | ||
| from homeassistant.util import Throttle | ||
|
|
||
| DOMAIN = 'stiebel_eltron' | ||
|
|
||
| CONFIG_SCHEMA = vol.Schema({ | ||
| DOMAIN: vol.Schema({ | ||
| vol.Optional(CONF_NAME, default=DEVICE_DEFAULT_NAME): cv.string, | ||
| vol.Optional(CONF_HUB, default=DEFAULT_HUB): cv.string, | ||
| }) | ||
| }, extra=vol.ALLOW_EXTRA) | ||
|
|
||
| _LOGGER = logging.getLogger(__name__) | ||
|
|
||
| MIN_TIME_BETWEEN_UPDATES = timedelta(seconds=30) | ||
|
|
||
|
|
||
| def setup(hass, config): | ||
| """Set up the STIEBEL ELTRON unit. | ||
|
|
||
| Will automatically load climate platform. | ||
| """ | ||
| name = config[DOMAIN][CONF_NAME] | ||
| modbus_client = hass.data[MODBUS_DOMAIN][config[DOMAIN][CONF_HUB]] | ||
|
|
||
| hass.data[DOMAIN] = { | ||
| 'name': name, | ||
| 'ste_data': StiebelEltronData(name, modbus_client) | ||
| } | ||
|
|
||
| discovery.load_platform(hass, 'climate', DOMAIN, {}, config) | ||
| return True | ||
|
|
||
|
|
||
| class StiebelEltronData: | ||
| """Get the latest data and update the states.""" | ||
|
|
||
| def __init__(self, name, modbus_client): | ||
| """Init the STIEBEL ELTRON data object.""" | ||
| from pystiebeleltron import pystiebeleltron | ||
| self.api = pystiebeleltron.StiebelEltronAPI(modbus_client, 1) | ||
|
|
||
| @Throttle(MIN_TIME_BETWEEN_UPDATES) | ||
| def update(self): | ||
| """Update unit data.""" | ||
| if not self.api.update(): | ||
| _LOGGER.warning("Modbus read failed") | ||
| else: | ||
| _LOGGER.debug("Data updated successfully") | ||
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
| Original file line number | Diff line number | Diff line change |
|---|---|---|
| @@ -0,0 +1,149 @@ | ||
| """Support for stiebel_eltron climate platform.""" | ||
| import logging | ||
|
|
||
| from homeassistant.components.climate import ClimateDevice | ||
| from homeassistant.components.climate.const import ( | ||
| STATE_AUTO, STATE_ECO, STATE_MANUAL, SUPPORT_OPERATION_MODE, | ||
| SUPPORT_TARGET_TEMPERATURE) | ||
| from homeassistant.const import ( | ||
| ATTR_TEMPERATURE, STATE_OFF, STATE_ON, TEMP_CELSIUS) | ||
|
|
||
| from . import DOMAIN as STE_DOMAIN | ||
|
|
||
| DEPENDENCIES = ['stiebel_eltron'] | ||
|
|
||
| _LOGGER = logging.getLogger(__name__) | ||
|
|
||
|
|
||
| SUPPORT_FLAGS = SUPPORT_TARGET_TEMPERATURE | SUPPORT_OPERATION_MODE | ||
| OPERATION_MODES = [STATE_AUTO, STATE_MANUAL, STATE_ECO, STATE_OFF] | ||
|
|
||
| # Mapping STIEBEL ELTRON states to homeassistant states. | ||
| STE_TO_HA_STATE = {'AUTOMATIC': STATE_AUTO, | ||
| 'MANUAL MODE': STATE_MANUAL, | ||
| 'STANDBY': STATE_ECO, | ||
| 'DAY MODE': STATE_ON, | ||
| 'SETBACK MODE': STATE_ON, | ||
| 'DHW': STATE_OFF, | ||
| 'EMERGENCY OPERATION': STATE_ON} | ||
|
|
||
| # Mapping homeassistant states to STIEBEL ELTRON states. | ||
| HA_TO_STE_STATE = {value: key for key, value in STE_TO_HA_STATE.items()} | ||
|
|
||
|
|
||
| def setup_platform(hass, config, add_entities, discovery_info=None): | ||
| """Set up the StiebelEltron platform.""" | ||
| name = hass.data[STE_DOMAIN]['name'] | ||
| ste_data = hass.data[STE_DOMAIN]['ste_data'] | ||
|
|
||
| add_entities([StiebelEltron(name, ste_data)], True) | ||
|
|
||
|
|
||
| class StiebelEltron(ClimateDevice): | ||
| """Representation of a STIEBEL ELTRON heat pump.""" | ||
|
|
||
| def __init__(self, name, ste_data): | ||
| """Initialize the unit.""" | ||
| self._name = name | ||
| self._target_temperature = None | ||
| self._current_temperature = None | ||
| self._current_humidity = None | ||
| self._operation_modes = OPERATION_MODES | ||
| self._current_operation = None | ||
| self._filter_alarm = None | ||
| self._force_update = False | ||
| self._ste_data = ste_data | ||
|
|
||
| @property | ||
| def supported_features(self): | ||
| """Return the list of supported features.""" | ||
| return SUPPORT_FLAGS | ||
|
|
||
| def update(self): | ||
| """Update unit attributes.""" | ||
| self._ste_data.update(no_throttle=self._force_update) | ||
| self._force_update = False | ||
|
|
||
| self._target_temperature = self._ste_data.api.get_target_temp() | ||
| self._current_temperature = self._ste_data.api.get_current_temp() | ||
| self._current_humidity = self._ste_data.api.get_current_humidity() | ||
| self._filter_alarm = self._ste_data.api.get_filter_alarm_status() | ||
| self._current_operation = self._ste_data.api.get_operation() | ||
|
|
||
| _LOGGER.debug("Update %s, current temp: %s", self._name, | ||
| self._current_temperature) | ||
|
|
||
| @property | ||
| def device_state_attributes(self): | ||
| """Return device specific state attributes.""" | ||
| return { | ||
| 'filter_alarm': self._filter_alarm | ||
| } | ||
|
|
||
| @property | ||
| def name(self): | ||
| """Return the name of the climate device.""" | ||
| return self._name | ||
|
|
||
| # Handle SUPPORT_TARGET_TEMPERATURE | ||
| @property | ||
| def temperature_unit(self): | ||
| """Return the unit of measurement.""" | ||
| return TEMP_CELSIUS | ||
|
|
||
| @property | ||
| def current_temperature(self): | ||
| """Return the current temperature.""" | ||
| return self._current_temperature | ||
|
|
||
| @property | ||
| def target_temperature(self): | ||
| """Return the temperature we try to reach.""" | ||
| return self._target_temperature | ||
|
|
||
| @property | ||
| def target_temperature_step(self): | ||
| """Return the supported step of target temperature.""" | ||
| return 0.1 | ||
|
|
||
| @property | ||
| def min_temp(self): | ||
| """Return the minimum temperature.""" | ||
| return 10.0 | ||
|
|
||
| @property | ||
| def max_temp(self): | ||
| """Return the maximum temperature.""" | ||
| return 30.0 | ||
|
|
||
| def set_temperature(self, **kwargs): | ||
| """Set new target temperature.""" | ||
| target_temperature = kwargs.get(ATTR_TEMPERATURE) | ||
| if target_temperature is not None: | ||
| _LOGGER.debug("set_temperature: %s", target_temperature) | ||
| self._ste_data.api.set_target_temp(target_temperature) | ||
| self._force_update = True | ||
|
|
||
| @property | ||
| def current_humidity(self): | ||
| """Return the current humidity.""" | ||
| return float("{0:.1f}".format(self._current_humidity)) | ||
|
|
||
| # Handle SUPPORT_OPERATION_MODE | ||
| @property | ||
| def operation_list(self): | ||
| """List of the operation modes.""" | ||
| return self._operation_modes | ||
|
|
||
| @property | ||
| def current_operation(self): | ||
| """Return current operation ie. heat, cool, idle.""" | ||
| return STE_TO_HA_STATE.get(self._current_operation) | ||
|
|
||
| def set_operation_mode(self, operation_mode): | ||
| """Set new operation mode.""" | ||
| new_mode = HA_TO_STE_STATE.get(operation_mode) | ||
| _LOGGER.debug("set_operation_mode: %s -> %s", self._current_operation, | ||
| new_mode) | ||
| self._ste_data.api.set_operation(new_mode) | ||
| self._force_update = True |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
| Original file line number | Diff line number | Diff line change |
|---|---|---|
| @@ -0,0 +1,14 @@ | ||
| { | ||
| "domain": "stiebel_eltron", | ||
| "name": "STIEBEL ELTRON", | ||
| "documentation": "https://www.home-assistant.io/components/stiebel_eltron", | ||
| "requirements": [ | ||
| "pystiebeleltron==0.0.1.dev2" | ||
| ], | ||
| "dependencies": [ | ||
| "modbus" | ||
| ], | ||
| "codeowners": [ | ||
| "@fucm" | ||
| ] | ||
| } |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Uh oh!
There was an error while loading. Please reload this page.