Notifications
You must be signed in to change notification settings - Fork 729
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Disable schedule on Tuya/Saswell TRV (TS601/_TZE200_c88teujp) #1816
Changes from all commits
File filter
Filter by extension
Conversations
Jump to
Diff view
Diff view
There are no files selected for viewing
Original file line number | Diff line number | Diff line change |
---|---|---|
|
@@ -4,18 +4,9 @@ | |
|
||
from zigpy.profiles import zha | ||
import zigpy.types as t | ||
from zigpy.zcl.clusters.general import ( | ||
Basic, | ||
Groups, | ||
Identify, | ||
Ota, | ||
PowerConfiguration, | ||
Scenes, | ||
Time, | ||
) | ||
from zigpy.zcl.clusters.general import Basic, Groups, Identify, Ota, Scenes, Time | ||
from zigpy.zcl.clusters.hvac import Thermostat | ||
|
||
from zhaquirks import LocalDataCluster | ||
from zhaquirks.const import ( | ||
DEVICE_TYPE, | ||
ENDPOINTS, | ||
|
@@ -26,21 +17,18 @@ | |
) | ||
from zhaquirks.tuya import ( | ||
TuyaManufClusterAttributes, | ||
TuyaPowerConfigurationCluster, | ||
TuyaThermostat, | ||
TuyaThermostatCluster, | ||
) | ||
|
||
_LOGGER = logging.getLogger(__name__) | ||
|
||
OCCUPIED_HEATING_SETPOINT_REPORTED = "occupied_heating_setpoint_reported" | ||
SYSTEM_MODE_REPORTED = "system_mode_reported" | ||
LOCAL_TEMP_REPORTED = "local_temp_reported" | ||
BATTERY_REPORTED = "battery_reported" | ||
|
||
OCCUPIED_HEATING_SETPOINT_COMMAND_ID = 615 | ||
SYSTEM_MODE_COMMAND_ID = 357 | ||
LOCAL_TEMP_COMMAND_ID = 614 | ||
BATTERY_STATE_COMMAND_ID = 1385 | ||
SASSWEL_HEATING_SETPOINT_ATTR = 0x0267 | ||
SASSWEL_STATE_ATTR = 0x0165 | ||
SASSWEL_LOCAL_TEMP_ATTR = 0x0266 | ||
SASSWEL_BATTERY_LOW_ATTR = 0x0569 | ||
SASSWEL_SCHEDULE_ENABLE_ATTR = 0x016C | ||
|
||
CTRL_SEQ_OF_OPER_ATTR = 0x001B | ||
|
||
|
@@ -49,63 +37,62 @@ | |
|
||
|
||
class ManufacturerThermostatCluster(TuyaManufClusterAttributes): | ||
"""Manufacturer thermostat cluster.""" | ||
"""Tuya manufacturer specific cluster.""" | ||
|
||
class State(t.enum8): | ||
"""State option.""" | ||
|
||
Off = 0x00 | ||
On = 0x01 | ||
|
||
class BatteryState(t.enum8): | ||
"""Battery state option.""" | ||
|
||
Normal = 0x00 | ||
Low = 0x01 | ||
|
||
class ScheduleState(t.enum8): | ||
"""Schedule state option.""" | ||
|
||
Disabled = 0x00 | ||
Enabled = 0x01 | ||
|
||
attributes = TuyaManufClusterAttributes.attributes.copy() | ||
attributes.update( | ||
{ | ||
SYSTEM_MODE_COMMAND_ID: ("system_mode", t.uint8_t, True), | ||
OCCUPIED_HEATING_SETPOINT_COMMAND_ID: ( | ||
"occupied_heating_setpoint", | ||
t.uint32_t, | ||
True, | ||
), | ||
LOCAL_TEMP_COMMAND_ID: ("local_temperature", t.uint32_t, True), | ||
BATTERY_STATE_COMMAND_ID: ("battery_state", t.uint8_t, True), | ||
SASSWEL_STATE_ATTR: ("state", State, True), | ||
SASSWEL_HEATING_SETPOINT_ATTR: ("heating_setpoint", t.uint32_t, True), | ||
SASSWEL_LOCAL_TEMP_ATTR: ("local_temperature", t.uint32_t, True), | ||
SASSWEL_BATTERY_LOW_ATTR: ("battery_state", BatteryState, True), | ||
SASSWEL_SCHEDULE_ENABLE_ATTR: ("schedule_enabled", ScheduleState, True), | ||
} | ||
) | ||
|
||
TEMPERATURE_ATTRS = { | ||
SASSWEL_HEATING_SETPOINT_ATTR: "occupied_heating_setpoint", | ||
SASSWEL_LOCAL_TEMP_ATTR: "local_temperature", | ||
} | ||
|
||
def _update_attribute(self, attrid, value): | ||
super()._update_attribute(attrid, value) | ||
if attrid == OCCUPIED_HEATING_SETPOINT_COMMAND_ID: | ||
if attrid in self.TEMPERATURE_ATTRS: | ||
self.endpoint.device.thermostat_bus.listener_event( | ||
OCCUPIED_HEATING_SETPOINT_REPORTED, value | ||
"temperature_change", | ||
self.TEMPERATURE_ATTRS[attrid], | ||
value * 10, | ||
) | ||
elif attrid == SYSTEM_MODE_COMMAND_ID: | ||
elif attrid == SASSWEL_STATE_ATTR: | ||
self.endpoint.device.thermostat_bus.listener_event( | ||
SYSTEM_MODE_REPORTED, value | ||
"system_mode_reported", value | ||
) | ||
elif attrid == BATTERY_STATE_COMMAND_ID: | ||
self.endpoint.device.battery_bus.listener_event(BATTERY_REPORTED, value) | ||
elif attrid == LOCAL_TEMP_COMMAND_ID: | ||
self.endpoint.device.thermostat_bus.listener_event( | ||
LOCAL_TEMP_REPORTED, value | ||
elif attrid == SASSWEL_BATTERY_LOW_ATTR: | ||
# this device doesn't have battery level reporting, only battery low alert | ||
# when the alert is active (1) we report 0% and 100% otherwise (0) | ||
self.endpoint.device.battery_bus.listener_event( | ||
"battery_change", 0 if value == 1 else 100 | ||
) | ||
|
||
|
||
class PowerConfigurationCluster(LocalDataCluster, PowerConfiguration): | ||
"""Power configuration cluster.""" | ||
|
||
cluster_id = PowerConfiguration.cluster_id | ||
|
||
def __init__(self, *args, **kwargs): | ||
"""Init.""" | ||
super().__init__(*args, **kwargs) | ||
self.endpoint.device.battery_bus.add_listener(self) | ||
|
||
def battery_reported(self, value): | ||
"""Handle reported battery state.""" | ||
_LOGGER.debug("reported battery alert: %d", value) | ||
if value == 1: # alert | ||
self._update_attribute( | ||
self.attributes_by_name["battery_percentage_remaining"].id, 0 | ||
) # report 0% battery | ||
else: | ||
self._update_attribute( | ||
self.attributes_by_name["battery_percentage_remaining"].id, 200 | ||
) # report 100% battery | ||
|
||
|
||
class ThermostatCluster(TuyaThermostatCluster): | ||
"""Thermostat cluster.""" | ||
|
||
|
@@ -117,25 +104,6 @@ class ThermostatCluster(TuyaThermostatCluster): | |
CTRL_SEQ_OF_OPER_ATTR: Thermostat.ControlSequenceOfOperation.Heating_Only, # the device supports heating mode | ||
} | ||
|
||
def __init__(self, *args, **kwargs): | ||
"""Init.""" | ||
super().__init__(*args, **kwargs) | ||
self.endpoint.device.thermostat_bus.add_listener(self) | ||
|
||
def occupied_heating_setpoint_reported(self, value): | ||
"""Handle reported occupied heating setpoint state.""" | ||
self._update_attribute( | ||
self.attributes_by_name["occupied_heating_setpoint"].id, value * 10 | ||
) | ||
_LOGGER.debug("reported occupied heating setpoint: %d", value) | ||
|
||
def local_temp_reported(self, value): | ||
"""Handle reported local temperature.""" | ||
self._update_attribute( | ||
self.attributes_by_name["local_temperature"].id, value * 10 | ||
) | ||
_LOGGER.debug("reported local temperature: %d", value) | ||
|
||
def system_mode_reported(self, value): | ||
"""Handle reported system mode.""" | ||
if value == 1: | ||
|
@@ -160,23 +128,21 @@ def map_attribute(self, attribute, value): | |
|
||
if attribute == "occupied_heating_setpoint": | ||
# centidegree to decidegree | ||
return {OCCUPIED_HEATING_SETPOINT_COMMAND_ID: round(value / 10)} | ||
return {SASSWEL_HEATING_SETPOINT_ATTR: round(value / 10)} | ||
Comment on lines
129
to
+131
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. I feel like there is something wrong here. At first sign there is an asymetric behavior with the temp attributes ( There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. There is no need to handle local temperature in |
||
|
||
if attribute == "system_mode": | ||
# this quirk does not support programmig modes so we force the schedule mode to be always off | ||
# more details: https://github.com/zigpy/zha-device-handlers/issues/1815 | ||
if value == self.SystemMode.Off: | ||
return {SYSTEM_MODE_COMMAND_ID: 0} | ||
return {SASSWEL_STATE_ATTR: 0, SASSWEL_SCHEDULE_ENABLE_ATTR: 0} | ||
if value == self.SystemMode.Heat: | ||
return {SYSTEM_MODE_COMMAND_ID: 1} | ||
return {SASSWEL_STATE_ATTR: 1, SASSWEL_SCHEDULE_ENABLE_ATTR: 0} | ||
|
||
|
||
class Thermostat_TYST11_c88teujp(TuyaThermostat): | ||
"""Saswell 88teujp thermostat valve.""" | ||
|
||
signature = { | ||
# <SimpleDescriptor endpoint=1 profile=260 device_type=0 | ||
# device_version=0 | ||
# input_clusters=[0, 3] | ||
# output_clusters=[3, 25]> | ||
MODELS_INFO: [ | ||
("_TYST11_KGbxAXL2", "GbxAXL2"), | ||
("_TYST11_c88teujp", "88teujp"), | ||
|
@@ -186,6 +152,10 @@ class Thermostat_TYST11_c88teujp(TuyaThermostat): | |
("_TYST11_zuhszj9s", "uhszj9s"), | ||
], | ||
ENDPOINTS: { | ||
# <SimpleDescriptor endpoint=1 profile=260 device_type=0 | ||
# device_version=0 | ||
# input_clusters=[0, 3] | ||
# output_clusters=[3, 25]> | ||
1: { | ||
PROFILE_ID: zha.PROFILE_ID, | ||
DEVICE_TYPE: zha.DeviceType.ON_OFF_SWITCH, | ||
|
@@ -208,16 +178,14 @@ class Thermostat_TYST11_c88teujp(TuyaThermostat): | |
DEVICE_TYPE: zha.DeviceType.THERMOSTAT, | ||
INPUT_CLUSTERS: [ | ||
Basic.cluster_id, | ||
TuyaPowerConfigurationCluster, | ||
Identify.cluster_id, | ||
ManufacturerThermostatCluster, | ||
PowerConfigurationCluster, | ||
ThermostatCluster, | ||
ManufacturerThermostatCluster, | ||
], | ||
OUTPUT_CLUSTERS: [ | ||
Identify.cluster_id, | ||
Ota.cluster_id, | ||
PowerConfigurationCluster, | ||
ThermostatCluster, | ||
], | ||
} | ||
}, | ||
|
@@ -228,8 +196,6 @@ class Thermostat_TZE200_c88teujp(TuyaThermostat): | |
"""Saswell 88teujp thermostat valve.""" | ||
|
||
signature = { | ||
# endpoint=1 profile=260 device_type=81 device_version=0 input_clusters=[0, 4, 5, 61184] | ||
# output_clusters=[10, 25]> | ||
MODELS_INFO: [ | ||
("_TZE200_c88teujp", "TS0601"), | ||
("_TZE200_azqp6ssj", "TS0601"), | ||
|
@@ -239,6 +205,10 @@ class Thermostat_TZE200_c88teujp(TuyaThermostat): | |
("_TZE200_2ekuz3dz", "TS0601"), | ||
], | ||
ENDPOINTS: { | ||
# <SimpleDescriptor endpoint=1 profile=260 device_type=81 | ||
# device_version=0 | ||
# input_clusters=[0, 4, 5, 61184] | ||
# output_clusters=[10, 25]> | ||
1: { | ||
PROFILE_ID: zha.PROFILE_ID, | ||
DEVICE_TYPE: zha.DeviceType.SMART_PLUG, | ||
|
@@ -260,18 +230,13 @@ class Thermostat_TZE200_c88teujp(TuyaThermostat): | |
DEVICE_TYPE: zha.DeviceType.THERMOSTAT, | ||
INPUT_CLUSTERS: [ | ||
Basic.cluster_id, | ||
TuyaPowerConfigurationCluster, | ||
Groups.cluster_id, | ||
Scenes.cluster_id, | ||
ManufacturerThermostatCluster, | ||
PowerConfigurationCluster, | ||
ThermostatCluster, | ||
], | ||
OUTPUT_CLUSTERS: [ | ||
Time.cluster_id, | ||
Ota.cluster_id, | ||
PowerConfigurationCluster, | ||
ThermostatCluster, | ||
ManufacturerThermostatCluster, | ||
blazewicz marked this conversation as resolved.
Show resolved
Hide resolved
|
||
], | ||
OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id], | ||
} | ||
} | ||
} |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Is that correct?
In
TEMPERATURE_ATTRS
isoccupied_heating_setpoint
, also in line 129 (if attribute == "occupied_heating_setpoint":
)There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
I see how that's tricky, let me try to explain.
ZCL Thermostat class uses
occupied_heating_setpoint
this is the attribute name which zigpy sends to the quirk when user requests setpoint change. Unit used by ZCL is centidegree Celsius (22,4 °C = 2240)Tuya thermostat uses different set of attributes and the name used by Tuya developers is simply "heating setpoint", I've used different name to avoid confusion between ZCL and Tuya attributes which use different units. Unit used by Tuya is decidegree Celsius (22,4 °C = 224).
When zigpy updates the value for ZCL Thermostat, (i.e. when user changes setpoint in HA dashboard) it calls
ThermostatCluster.map_attribute()
withattribute = "occupied_heating_setpoint"
. This method converts the value from centidegree to decidegree and translates ZCL'soccupied_heating_setpoint
to Tuya'sSASSWEL_HEATING_SETPOINT_ATTR
.On the other hand device reports two temperature values with attrids:
SASSWEL_HEATING_SETPOINT_ATTR
andSASSWEL_LOCAL_TEMP_ATTR
. First is the current heating setpoint and the second is the local temperature as measured by the temperature sensor on the device. Both reported values are handled by the same event listener implemented inTuyaThermostatCluster.temperature_change()
. To make code simpler both reports are handled by lines 78:83 and Tuya->ZCL attribute name translation is handled by theTEMPERATURE_ATTRS
mapping, both values require the same *10 conversion from Tuya to ZCL standard.