Notifications
You must be signed in to change notification settings - Fork 82
Closed
Labels
configurationUser configuration issueUser configuration issue
Description
I got problem that this 2 are always set to 5A limiting my charge and discharge, how can i solve that ?
timed_charge_current:
- number.inverter_battery_inverter_battery_charge_current_limit
timed_discharge_current: - number.inverter_battery_inverter_battery_discharge_current_limit
Feels like it dose not under stand max charge rate etc ? since in 2 hours my battery shoul be able to discharge 20kwh ?
For this 2 it set them to 20% , can i adjust how low it can set them my battery support much lower?
reserve:
- number.inverter_battery_inverter_battery_soc_min_on_grid
battery_min_soc:
- number.inverter_battery_inverter_battery_soc_min_off_grid
also when it change state
it do the state to start the new state then end the old one so it always do 2 commands.
for example it do:
charge_start_service
discharge_stop_service
And since it do in that order it set the latest state (i solve that with my script to only to 1 command)
app.yaml
pred_bat:
module: predbat
class: PredBat
prefix: predbat
timezone: Europe/Stockholm
currency_symbols:
- "SEK"
- "öre"
threads: auto
run_every: 5
load_filter_threshold: 60
num_cars: 0
num_inverters: 1
soc_max:
- 25.6
notify_devices:
- mobile_app_sm_s921b
battery_rate_max:
- 10000
inverter_limit: 17000
load_today:
- sensor.consumed_today
import_today:
- sensor.energy_meter_consumed_day
export_today:
- sensor.energy_meter_produced_day
pv_today:
- sensor.total_pv_generation_today
soc_percent:
- sensor.inverter_battery_inverter_battery_soc
battery_power:
- sensor.inverter_battery_inverter_battery_power
pv_power:
- sensor.total_current_pv_power
load_power:
- sensor.current_consumed
grid_power:
- sensor.net_grid_power_flow
battery_voltage:
- sensor.inverter_battery_inverter_battery_voltage
inverter_limit_charge:
- 10000
inverter_limit_discharge:
- 10000
timed_charge_current:
- number.inverter_battery_inverter_battery_charge_current_limit
timed_discharge_current:
- number.inverter_battery_inverter_battery_discharge_current_limit
pv_forecast_today: sensor.pv_forecast_today_sum
pv_forecast_tomorrow: sensor.pv_forecast_tomorrow_sum
pv_forecast_d3: sensor.pv_forecast_day_2_sum
pv_forecast_d4: sensor.pv_forecast_day_3_sum
# -- Energy Rates (Energi Data Service) --
metric_energidataservice_import: "sensor.energi_data_service_buy_price_15min"
metric_energidataservice_export: "sensor.energi_data_service_15min"
# Set your daily standing charge in SEK if you have one.
metric_standing_charge: 0
# -- Prediction & Planning Settings --
days_previous:
- 1
- 2
- 7
- 14
- 21
days_previous_weight:
- 0.7
- 0.7
- 1
- 0.5
- 0.5
forecast_hours: 48
battery_carge_power_curve:
91: 0.91
92: 0.82
93: 0.72
94: 0.62
95: 0.52
96: 0.43
97: 0.33
98: 0.24
99: 0.24
100: 0.24
reserve:
- number.inverter_battery_inverter_battery_soc_min_on_grid
battery_min_soc:
- number.inverter_battery_inverter_battery_soc_min_off_grid
# Try custom inverter
inverter:
name: "Solinteg"
has_rest_api: False
has_mqtt_api: False
has_service_api: True
output_charge_control: "current"
has_charge_enable_time: False
has_discharge_enable_time: False
charge_control_immediate: False
current_dp: 1
has_target_soc: False
has_reserve_soc: True
has_timed_pause: False
charge_time_format: "S"
charge_time_entity_is_option: False
soc_units: "%"
num_load_entities: 1
has_ge_inverter_mode: False
time_button_press: False
clock_time_format: "%Y-%m-%d %H:%M:%S"
write_and_poll_sleep: 2
has_time_window: False
support_charge_freeze: False
support_discharge_freeze": False
has_idle_time: False
can_span_midnight: True
charge_start_service:
- service: script.set_inverter_mode
mode: UPS
log_reason: 'charge_start_service'
repeat: True
charge_stop_service:
- service: script.set_inverter_mode
mode: General
log_reason: 'charge_stop_service'
repeat: True
discharge_start_service:
- service: script.set_inverter_mode
mode: Economic
log_reason: 'discharge_start_service'
repeat: True
discharge_stop_service:
- service: script.set_inverter_mode
mode: General
log_reason: 'discharge_stop_service'
repeat: True
discharge_freeze_service:
- service: script.set_inverter_mode
mode: General
log_reason: 'discharge_freeze_service'
repeat: True
Here is the script for my inverter if anyone wants it.
fields:
mode:
name: Working Mode
description: The desired working mode for the inverter.
required: true
selector:
select:
options:
- General
- Economic
- UPS
- PeakShift
- Feed-In
- Off-Grid
- ToU
log_reason:
name: Log Reason
description: (Optional) A reason for the action, for logging purposes.
selector:
text: null
default: default
sequence:
- variables:
stop_reasons:
- charge_stop_service
- discharge_stop_service
- condition: template
value_template: >-
{{ (now() - (state_attr('script.set_inverter_mode', 'last_triggered') |
default(as_datetime(0)))) > timedelta(seconds=20) or log_reason not in
stop_reasons }}
- choose:
- conditions:
- condition: template
value_template: >-
{{ mode not in ['General', 'Economic', 'UPS', 'PeakShift',
'Feed-In', 'Off-Grid', 'ToU'] }}
sequence:
- data:
title: Invalid Inverter Mode Provided
message: >-
'{{ mode }}' is not a valid working mode. Please use one of the
allowed options.
action: persistent_notification.create
default:
- variables:
previous_mode: "{{ states('select.inverter_battery_inverter_working_mode') }}"
- condition: template
value_template: "{{ previous_mode != mode }}"
- target:
entity_id: select.inverter_battery_inverter_working_mode
data:
option: "{{ mode }}"
action: select.select_option
- delay:
seconds: 5
- choose:
- conditions:
- condition: template
value_template: >-
{{ states('select.inverter_battery_inverter_working_mode') ==
mode }}
sequence:
- data:
title: ✅ Inverter Mode Changed Successfully
message: >-
Reason {{ log_reason }}. Inverter working mode was changed
from **{{ previous_mode }}** to **{{ mode }}**.
action: persistent_notification.create
default:
- data:
title: ❌ Failed to Change Inverter Mode
message: >-
Reason {{ log_reason }}. Attempted to change inverter mode to
**{{ mode }}**, but the change failed. The current mode is still
**{{ states('select.inverter_battery_inverter_working_mode')
}}**.
action: persistent_notification.create
mode: single
Metadata
Metadata
Assignees
Labels
configurationUser configuration issueUser configuration issue