@key4ng key4ng commented Jun 12, 2026 •

Copy link
Copy Markdown
Member

Reverts #1627 since the boot volume extends from 100GB and 360GB which have enough runner space

Summary by CodeRabbit

  • Documentation

    • Removed obsolete H100 NVMe storage guidance from the Kubernetes runner docs.
  • Chores

    • Simplified GPU H100 runner storage and Docker wiring: moved to in-pod ephemeral storage, removed per-pod subpath mounts and lifecycle cleanup steps, and streamlined container mounts and env settings across runner configurations.

@github-actions github-actions Bot added the documentation Improvements or additions to documentation label Jun 12, 2026
@coderabbitai

coderabbitai Bot commented Jun 12, 2026 •

Copy link
Copy Markdown

Review Change Stack

📝 Walkthrough

Walkthrough

Switches H100 runner pod storage from hostPath-mounted per-pod NVMe to in-pod emptyDir, removes POD_NAME-based per-pod wiring and dind preStop cleanup, updates runner and dind volume mounts, and deletes the README section describing NVMe setup.

Changes

H100 GPU Runner Storage Migration

Layer / File(s) Summary
Documentation update: Remove H100 NVMe Storage section
scripts/k8s-runner-resources/README.md
The "H100 Runner NVMe Storage" subsection (mounting /raid/actions-runner, per-pod subPathExpr guidance, preStop cleanup, and legacy caveats) was removed.
Volume definitions: hostPath → emptyDir migration
scripts/k8s-runner-resources/runner-values-1-gpu-h100.yaml, scripts/k8s-runner-resources/runner-values-2-gpu-h100.yaml, scripts/k8s-runner-resources/runner-values-4-gpu-h100.yaml
Pod volumes updated: work and docker-storage now use emptyDir, and the hostPath runner-nvme volume was removed across the three H100 values files.
Runner container env and mounts updates
scripts/k8s-runner-resources/runner-values-1-gpu-h100.yaml, scripts/k8s-runner-resources/runner-values-2-gpu-h100.yaml, scripts/k8s-runner-resources/runner-values-4-gpu-h100.yaml
Removed POD_NAME env var (sourced from metadata.name) and added direct mounts for dind-sock → /var/run and docker-storage → /var/lib/docker in runner container specs.
Dind container lifecycle and mounts cleanup
scripts/k8s-runner-resources/runner-values-1-gpu-h100.yaml, scripts/k8s-runner-resources/runner-values-2-gpu-h100.yaml, scripts/k8s-runner-resources/runner-values-4-gpu-h100.yaml
Removed lifecycle.preStop cleanup that deleted /runner-nvme/${POD_NAME} and rewrote dind volumeMounts to remove runner-nvme and per-pod subPathExpr, using direct mounts for _work, dind-sock, dind-externals, and docker-storage.

Estimated code review effort

🎯 3 (Moderate) | ⏱️ ~22 minutes

Possibly related PRs

  • lightseekorg/smg#659: Introduced the ARC H100 runner values that this PR refactors (volume/mount wiring and NVMe usage).
  • lightseekorg/smg#1627: Previously added per-pod NVMe hostPath, POD_NAME wiring, and preStop cleanup that this PR removes.

Suggested labels

ci

Suggested reviewers

  • CatherineSue
  • slin1237
  • gongwei-130
  • XinyueZhang369

Poem

🐰 I swapped the NVMe trails for emptyDir springs,

Pods now tidy where the shared docker bell rings.
No POD_NAME scurries nor preStop goodbyes,
Mounts simplified under calm GPU skies.
A rabbit hops light — configs trimmed, ready to sing.

🚥 Pre-merge checks | ✅ 4 | ❌ 1

❌ Failed checks (1 warning)

Check name Status Explanation Resolution
Title check ⚠️ Warning The title 'revert(ci): use NVMe storage for H100 runner workspaces' is misleading—it describes adding NVMe storage, but the PR actually removes it. Revise the title to accurately reflect the change, such as 'revert(ci): remove NVMe storage for H100 runner workspaces' or 'revert(ci): revert NVMe storage changes for H100 runners'.
✅ Passed checks (4 passed)
Check name Status Explanation
Description Check ✅ Passed Check skipped - CodeRabbit’s high-level summary is enabled.
Docstring Coverage ✅ Passed No functions found in the changed files to evaluate docstring coverage. Skipping docstring coverage check.
Linked Issues check ✅ Passed Check skipped because no linked issues were found for this pull request.
Out of Scope Changes check ✅ Passed Check skipped because no linked issues were found for this pull request.

✏️ Tip: You can configure your own custom pre-merge checks in the settings.

✨ Finishing Touches
🧪 Generate unit tests (beta)
  • Create PR with unit tests
  • Commit unit tests in branch revert-1627-fix/h100-runner-nvme-workspaces-pr

Comment @coderabbitai help to get the list of available commands and usage tips.

@mergify

mergify Bot commented Jun 12, 2026

Copy link
Copy Markdown
Contributor

Hi @key4ng, the DCO sign-off check has failed. All commits must include a Signed-off-by line.

To fix existing commits:

# Sign off the last N commits (replace N with the number of unsigned commits)
git rebase HEAD~N --signoff
git push --force-with-lease

To sign off future commits automatically:

  • Use git commit -s every time, or
  • VSCode: enable Git: Always Sign Off in Settings
  • PyCharm: enable Sign-off commit in the Commit tool window

@key4ng key4ng changed the title Revert "fix(ci): use NVMe storage for H100 runner workspaces" Revert: "fix(ci): use NVMe storage for H100 runner workspaces" Jun 12, 2026
@claude

claude Bot commented Jun 12, 2026 •

Copy link
Copy Markdown

👋 The PR description doesn't fully follow
PULL_REQUEST_TEMPLATE.md:

  • Missing header: ## Description
  • Missing header: ### Problem
  • Missing header: ### Solution
  • Missing header: ## Changes
  • Missing header: ## Test Plan

Please update the PR description so reviewers have the context they need.

This reverts commit 63b532a.

Signed-off-by: Keyang Ru <rukeyang@gmail.com>
mountPath: /var/lib/docker
subPathExpr: $(POD_NAME)/docker

initContainers:

Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

🟡 Nit: The removed prepare-runner-nvme init container also initialized model-cache PVC directories (/models/.locks, /models/hub, /models/hub/.locks) with correct ownership (1001:1001) and permissions (1777 on lock dirs). This side-effect is lost in the revert.

If the PVC already has these directories from previous pod runs this is fine, but if the PVC is ever re-provisioned (or a new cluster is set up), model caching may fail on first run due to missing directories or wrong permissions. Worth confirming this is covered elsewhere, or extracting the model-cache init into its own init container independent of the NVMe setup. Same applies to the 2-gpu and 4-gpu files.

@key4ng
key4ng force-pushed the revert-1627-fix/h100-runner-nvme-workspaces-pr branch from 7a838f6 to 6551395 Compare June 12, 2026 19:36

@claude claude Bot left a comment

Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Clean revert of #1627. The switch from NVMe hostPath back to emptyDir is consistent across all three H100 runner value files, and the associated cleanup infrastructure (subPathExpr, preStop hook, POD_NAME env vars, prepare-runner-nvme init container) is correctly removed.

One 🟡 nit posted about the model-cache PVC directory initialization that was a side-effect of the removed init container.

Summary: 0 🔴 Important · 1 🟡 Nit · 0 🟣 Pre-existing

@chatgpt-codex-connector chatgpt-codex-connector Bot left a comment

Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

💡 Codex Review

Here are some automated review suggestions for this pull request.

Reviewed commit: 7a838f671a

ℹ️ About Codex in GitHub

Your team has set up Codex to review pull requests in this repo. Reviews are triggered when you

  • Open a pull request for review
  • Mark a draft as ready
  • Comment "@codex review".

If Codex has suggestions, it will comment; otherwise it will react with 👍.

Codex can also answer questions or update the PR. Try commenting "@codex address that feedback".

mountPath: /var/lib/docker
subPathExpr: $(POD_NAME)/docker

initContainers:

Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

P2 Badge Preserve model-cache permission setup

When these H100 scale-set pods start with a fresh or root-owned model-cache PVC, dropping the prepare-runner-nvme init container also drops the only setup that created and chowned /models/.locks and /models/hub/.locks for uid 1001. The H100 workflows call scripts/ci_download_model.sh, which immediately does mkdir -p "$LOCK_DIR" and opens lock files under /models/.locks before downloading models, so those jobs can fail with permission denied even though the workspace/docker storage revert itself is intentional; keep a small model-cache init step or equivalent fsGroup/ownership setup in each H100 values file.

Useful? React with 👍 / 👎.

@key4ng key4ng changed the title Revert: "fix(ci): use NVMe storage for H100 runner workspaces" revert(ci): use NVMe storage for H100 runner workspaces Jun 12, 2026

@gemini-code-assist gemini-code-assist Bot left a comment

Copy link
Copy Markdown
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Code Review

This pull request removes hostPath-based NVMe storage configurations and associated cleanup logic across the H100 runner values files, replacing them with emptyDir volumes. However, removing the prepare-runner-nvme init container also deleted the permission and directory initialization for the shared model-cache volume. This will cause permission denied errors for the non-root runner container. It is recommended to add a dedicated prepare-model-cache init container to set up the necessary directories and permissions, and to disable TLS for the Docker socket in the DinD setup.

Important

The consumer version of Gemini Code Assist on GitHub is being sunset. Starting June 18, 2026, new organization installations will be blocked, and all code review activity will officially cease on July 17, 2026.
For more details on the timeline and next steps, please review the Help Documentation.

Comment on lines 92 to 93
initContainers:
- name: prepare-runner-nvme
image: fra.ocir.io/idqj093njucb/docker:dind
command:
- sh
- -c
- mkdir -p /runner-nvme/${POD_NAME}/_work /runner-nvme/${POD_NAME}/.cache /runner-nvme/${POD_NAME}/tmp /runner-nvme/${POD_NAME}/docker /models/.locks /models/hub /models/hub/.locks && chown -R 1001:1001 /runner-nvme/${POD_NAME} && chown 1001:1001 /models/.locks /models/hub /models/hub/.locks && chmod 1777 /runner-nvme/${POD_NAME}/tmp /models/.locks /models/hub/.locks
env:
- name: POD_NAME
valueFrom:
fieldRef:
fieldPath: metadata.name
volumeMounts:
- mountPath: /runner-nvme
name: runner-nvme
- mountPath: /models
name: model-cache
- name: init-dind-externals

Copy link
Copy Markdown
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

high

Removing the prepare-runner-nvme init container also removed the initialization and permission setup for the model-cache volume (/models/.locks, /models/hub, /models/hub/.locks). Since the runner container runs as a non-root user (UID 1001) and standard PVCs are often mounted as root-owned, the runner will fail to write to the model cache, leading to permission denied errors. We should add a dedicated prepare-model-cache init container to handle this setup. Additionally, when using a Docker-in-Docker (DinD) setup, it is necessary to disable TLS for the Docker socket by setting the DOCKER_TLS_CERTDIR environment variable to an empty string.

    initContainers:
      - name: prepare-model-cache
        image: fra.ocir.io/idqj093njucb/docker:dind
        env:
          - name: DOCKER_TLS_CERTDIR
            value: ""
        command:
          - sh
          - -c
          - mkdir -p /models/.locks /models/hub /models/hub/.locks && chown 1001:1001 /models/.locks /models/hub /models/hub/.locks && chmod 1777 /models/.locks /models/hub/.locks
        volumeMounts:
          - mountPath: /models
            name: model-cache
      - name: init-dind-externals
References
  1. When using a Docker-in-Docker (DinD) setup, it is necessary to disable TLS for the Docker socket by setting the DOCKER_TLS_CERTDIR environment variable to an empty string.

Comment on lines 92 to 93
initContainers:
- name: prepare-runner-nvme
image: fra.ocir.io/idqj093njucb/docker:dind
command:
- sh
- -c
- mkdir -p /runner-nvme/${POD_NAME}/_work /runner-nvme/${POD_NAME}/.cache /runner-nvme/${POD_NAME}/tmp /runner-nvme/${POD_NAME}/docker /models/.locks /models/hub /models/hub/.locks && chown -R 1001:1001 /runner-nvme/${POD_NAME} && chown 1001:1001 /models/.locks /models/hub /models/hub/.locks && chmod 1777 /runner-nvme/${POD_NAME}/tmp /models/.locks /models/hub/.locks
env:
- name: POD_NAME
valueFrom:
fieldRef:
fieldPath: metadata.name
volumeMounts:
- mountPath: /runner-nvme
name: runner-nvme
- mountPath: /models
name: model-cache
- name: init-dind-externals

Copy link
Copy Markdown
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

high

Removing the prepare-runner-nvme init container also removed the initialization and permission setup for the model-cache volume (/models/.locks, /models/hub, /models/hub/.locks). Since the runner container runs as a non-root user (UID 1001) and standard PVCs are often mounted as root-owned, the runner will fail to write to the model cache, leading to permission denied errors. We should add a dedicated prepare-model-cache init container to handle this setup. Additionally, when using a Docker-in-Docker (DinD) setup, it is necessary to disable TLS for the Docker socket by setting the DOCKER_TLS_CERTDIR environment variable to an empty string.

    initContainers:
      - name: prepare-model-cache
        image: fra.ocir.io/idqj093njucb/docker:dind
        env:
          - name: DOCKER_TLS_CERTDIR
            value: ""
        command:
          - sh
          - -c
          - mkdir -p /models/.locks /models/hub /models/hub/.locks && chown 1001:1001 /models/.locks /models/hub /models/hub/.locks && chmod 1777 /models/.locks /models/hub/.locks
        volumeMounts:
          - mountPath: /models
            name: model-cache
      - name: init-dind-externals
References
  1. When using a Docker-in-Docker (DinD) setup, it is necessary to disable TLS for the Docker socket by setting the DOCKER_TLS_CERTDIR environment variable to an empty string.

Comment on lines 91 to 92
initContainers:
- name: prepare-runner-nvme
image: fra.ocir.io/idqj093njucb/docker:dind
command:
- sh
- -c
- mkdir -p /runner-nvme/${POD_NAME}/_work /runner-nvme/${POD_NAME}/.cache /runner-nvme/${POD_NAME}/tmp /runner-nvme/${POD_NAME}/docker /models/.locks /models/hub /models/hub/.locks && chown -R 1001:1001 /runner-nvme/${POD_NAME} && chown 1001:1001 /models/.locks /models/hub /models/hub/.locks && chmod 1777 /runner-nvme/${POD_NAME}/tmp /models/.locks /models/hub/.locks
env:
- name: POD_NAME
valueFrom:
fieldRef:
fieldPath: metadata.name
volumeMounts:
- mountPath: /runner-nvme
name: runner-nvme
- mountPath: /models
name: model-cache
- name: init-dind-externals

Copy link
Copy Markdown
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

high

Removing the prepare-runner-nvme init container also removed the initialization and permission setup for the model-cache volume (/models/.locks, /models/hub, /models/hub/.locks). Since the runner container runs as a non-root user (UID 1001) and standard PVCs are often mounted as root-owned, the runner will fail to write to the model cache, leading to permission denied errors. We should add a dedicated prepare-model-cache init container to handle this setup. Additionally, when using a Docker-in-Docker (DinD) setup, it is necessary to disable TLS for the Docker socket by setting the DOCKER_TLS_CERTDIR environment variable to an empty string.

    initContainers:
      - name: prepare-model-cache
        image: fra.ocir.io/idqj093njucb/docker:dind
        env:
          - name: DOCKER_TLS_CERTDIR
            value: ""
        command:
          - sh
          - -c
          - mkdir -p /models/.locks /models/hub /models/hub/.locks && chown 1001:1001 /models/.locks /models/hub /models/hub/.locks && chmod 1777 /models/.locks /models/hub/.locks
        volumeMounts:
          - mountPath: /models
            name: model-cache
      - name: init-dind-externals
References
  1. When using a Docker-in-Docker (DinD) setup, it is necessary to disable TLS for the Docker socket by setting the DOCKER_TLS_CERTDIR environment variable to an empty string.

@coderabbitai coderabbitai Bot left a comment

Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Caution

Some comments are outside the diff and can’t be posted inline due to platform limitations.

⚠️ Outside diff range comments (1)
scripts/k8s-runner-resources/runner-values-1-gpu-h100.yaml (1)

47-62: ⚠️ Potential issue | 🟠 Major

Add ephemeral-storage requests/limits (and/or emptyDir.sizeLimit) for work and docker-storage in the H100 runner pods.

In scripts/k8s-runner-resources/runner-values-1-gpu-h100.yaml, runner-values-2-gpu-h100.yaml, and runner-values-4-gpu-h100.yaml, the work and docker-storage volumes are emptyDir: {} (no sizeLimit), and the runner/dind containers do not define resources.requests/limits.ephemeral-storage. Set ephemeral-storage requests/limits for the relevant containers (and/or emptyDir.sizeLimit for those volumes) so large workspaces and Docker pulls/layers don’t push the node into DiskPressure and cause evictions.

🤖 Prompt for AI Agents
Verify each finding against current code. Fix only still-valid issues, skip the
rest with a brief reason, keep changes minimal, and validate.

In `@scripts/k8s-runner-resources/runner-values-1-gpu-h100.yaml` around lines 47 -
62, The work and docker-storage emptyDir volumes currently lack size limits and
the runner/dind containers lack ephemeral-storage resource requests/limits; add
emptyDir.sizeLimit for the volumes named "work" and "docker-storage" and/or set
resources.requests.ephemeral-storage and resources.limits.ephemeral-storage on
the runner and dind containers (the containers that mount those volumes) in
runner-values-1-gpu-h100.yaml (and mirror the same changes to
runner-values-2-gpu-h100.yaml and runner-values-4-gpu-h100.yaml) so large
workspaces and Docker layers cannot exhaust node disk and cause DiskPressure
evictions.
🤖 Prompt for all review comments with AI agents
Verify each finding against current code. Fix only still-valid issues, skip the
rest with a brief reason, keep changes minimal, and validate.

Outside diff comments:
In `@scripts/k8s-runner-resources/runner-values-1-gpu-h100.yaml`:
- Around line 47-62: The work and docker-storage emptyDir volumes currently lack
size limits and the runner/dind containers lack ephemeral-storage resource
requests/limits; add emptyDir.sizeLimit for the volumes named "work" and
"docker-storage" and/or set resources.requests.ephemeral-storage and
resources.limits.ephemeral-storage on the runner and dind containers (the
containers that mount those volumes) in runner-values-1-gpu-h100.yaml (and
mirror the same changes to runner-values-2-gpu-h100.yaml and
runner-values-4-gpu-h100.yaml) so large workspaces and Docker layers cannot
exhaust node disk and cause DiskPressure evictions.

ℹ️ Review info
⚙️ Run configuration

Configuration used: Organization UI

Review profile: ASSERTIVE

Plan: Pro

Run ID: 37a064c6-4929-42d1-af90-f4c64396ddfb

📥 Commits

Reviewing files that changed from the base of the PR and between 856e353 and 7a838f6.

📒 Files selected for processing (4)
  • scripts/k8s-runner-resources/README.md
  • scripts/k8s-runner-resources/runner-values-1-gpu-h100.yaml
  • scripts/k8s-runner-resources/runner-values-2-gpu-h100.yaml
  • scripts/k8s-runner-resources/runner-values-4-gpu-h100.yaml
💤 Files with no reviewable changes (1)
  • scripts/k8s-runner-resources/README.md

@coderabbitai coderabbitai Bot left a comment

Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Caution

Some comments are outside the diff and can’t be posted inline due to platform limitations.

⚠️ Outside diff range comments (1)
scripts/k8s-runner-resources/runner-values-1-gpu-h100.yaml (1)

47-62: 🧹 Nitpick | 🔵 Trivial | 💤 Low value

Consider adding sizeLimit to unbounded emptyDir volumes.

The work and docker-storage volumes use emptyDir: {} without a sizeLimit. While the PR description indicates the 360GB boot volume should be sufficient, unbounded emptyDir volumes can cause node eviction if storage is exhausted during large builds or Docker image accumulation.

Adding explicit limits provides a safety guardrail against runaway storage consumption.

🛡️ Optional: Add sizeLimit for defensive storage management
     volumes:
       - name: work
-        emptyDir: {}
+        emptyDir:
+          sizeLimit: 100Gi
       - name: model-cache
         persistentVolumeClaim:
           claimName: model-cache
       - name: dshm
         emptyDir:
           medium: Memory
           sizeLimit: 16Gi
       - name: dind-sock
         emptyDir: {}
       - name: dind-externals
         emptyDir: {}
       - name: docker-storage
-        emptyDir: {}
+        emptyDir:
+          sizeLimit: 150Gi
🤖 Prompt for AI Agents
Verify each finding against current code. Fix only still-valid issues, skip the
rest with a brief reason, keep changes minimal, and validate.

In `@scripts/k8s-runner-resources/runner-values-1-gpu-h100.yaml` around lines 47 -
62, Add explicit sizeLimit values for the unbounded emptyDir volumes to prevent
node storage exhaustion: update the volumes named "work" and "docker-storage" to
include a sensible sizeLimit (e.g., "sizeLimit: 50Gi" or another value
appropriate for your workloads). Modify the YAML entries for the volumes with
emptyDir: {} to include an object with medium if needed and a sizeLimit field,
keeping consistency with the existing "dshm" volume pattern; ensure the chosen
limits align with the 360GB boot volume and cluster resource policies.
🤖 Prompt for all review comments with AI agents
Verify each finding against current code. Fix only still-valid issues, skip the
rest with a brief reason, keep changes minimal, and validate.

Outside diff comments:
In `@scripts/k8s-runner-resources/runner-values-1-gpu-h100.yaml`:
- Around line 47-62: Add explicit sizeLimit values for the unbounded emptyDir
volumes to prevent node storage exhaustion: update the volumes named "work" and
"docker-storage" to include a sensible sizeLimit (e.g., "sizeLimit: 50Gi" or
another value appropriate for your workloads). Modify the YAML entries for the
volumes with emptyDir: {} to include an object with medium if needed and a
sizeLimit field, keeping consistency with the existing "dshm" volume pattern;
ensure the chosen limits align with the 360GB boot volume and cluster resource
policies.

ℹ️ Review info
⚙️ Run configuration

Configuration used: Organization UI

Review profile: ASSERTIVE

Plan: Pro

Run ID: df5d2b15-ca0b-462f-b59a-7a4c9652b6b1

📥 Commits

Reviewing files that changed from the base of the PR and between 7a838f6 and 6551395.

📒 Files selected for processing (4)
  • scripts/k8s-runner-resources/README.md
  • scripts/k8s-runner-resources/runner-values-1-gpu-h100.yaml
  • scripts/k8s-runner-resources/runner-values-2-gpu-h100.yaml
  • scripts/k8s-runner-resources/runner-values-4-gpu-h100.yaml
💤 Files with no reviewable changes (1)
  • scripts/k8s-runner-resources/README.md

@key4ng
key4ng merged commit 09cee1d into main Jun 12, 2026
41 of 42 checks passed
@key4ng
key4ng deleted the revert-1627-fix/h100-runner-nvme-workspaces-pr branch June 12, 2026 22:09
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

documentation Improvements or additions to documentation

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant