Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

make the maximum output coefficient configurable #124

Merged
merged 1 commit into from
Jul 11, 2024
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
1 change: 1 addition & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -7,6 +7,7 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0

## [unreleased]

- make the maximum output coefficient configurable [#123](https://github.com/s-allius/tsun-gen3-proxy/issues/123)
- cleanup shutdown
- add preview build
- MODBUS: the last digit of the inverter version is a hexadecimal number [#119](https://github.com/s-allius/tsun-gen3-proxy/issues/119)
Expand Down
5 changes: 3 additions & 2 deletions app/src/infos.py
Original file line number Diff line number Diff line change
Expand Up @@ -18,6 +18,7 @@ class Register(Enum):
EQUIPMENT_MODEL = 24
NO_INPUTS = 25
MAX_DESIGNED_POWER = 26
OUTPUT_COEFFICIENT = 27
INVERTER_CNT = 50
UNKNOWN_SNR = 51
UNKNOWN_MSG = 52
Expand Down Expand Up @@ -194,9 +195,9 @@ def __init__(self):
Register.SERIAL_NUMBER: {'name': ['inverter', 'Serial_Number'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
Register.EQUIPMENT_MODEL: {'name': ['inverter', 'Equipment_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
Register.NO_INPUTS: {'name': ['inverter', 'No_Inputs'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
Register.MAX_DESIGNED_POWER: {'name': ['inverter', 'Max_Designed_Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'inverter', 'dev_cla': None, 'stat_cla': None, 'id': 'designed_power_', 'fmt': '| string + " W"', 'name': 'Max Designed Power', 'icon': 'mdi:lightning-bolt', 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.MAX_DESIGNED_POWER: {'name': ['inverter', 'Max_Designed_Power'], 'level': logging.INFO, 'unit': 'W', 'ha': {'dev': 'inverter', 'dev_cla': None, 'stat_cla': None, 'id': 'designed_power_', 'fmt': '| string + " W"', 'name': 'Max Designed Power', 'icon': 'mdi:lightning-bolt', 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.RATED_POWER: {'name': ['inverter', 'Rated_Power'], 'level': logging.DEBUG, 'unit': 'W', 'ha': {'dev': 'inverter', 'dev_cla': None, 'stat_cla': None, 'id': 'rated_power_', 'fmt': '| string + " W"', 'name': 'Rated Power', 'icon': 'mdi:lightning-bolt', 'ent_cat': 'diagnostic'}}, # noqa: E501

Register.OUTPUT_COEFFICIENT: {'name': ['inverter', 'Output_Coefficient'], 'level': logging.INFO, 'unit': '%', 'ha': {'dev': 'inverter', 'dev_cla': None, 'stat_cla': 'measurement', 'id': 'output_coef_', 'fmt': '| int', 'name': 'Output Coefficient', 'icon': 'mdi:lightning-bolt', 'ent_cat': 'diagnostic'}}, # noqa: E501
Register.PV1_MANUFACTURER: {'name': ['inverter', 'PV1_Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
Register.PV1_MODEL: {'name': ['inverter', 'PV1_Model'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
Register.PV2_MANUFACTURER: {'name': ['inverter', 'PV2_Manufacturer'], 'level': logging.DEBUG, 'unit': ''}, # noqa: E501
Expand Down
3 changes: 2 additions & 1 deletion app/src/modbus.py
Original file line number Diff line number Diff line change
Expand Up @@ -41,7 +41,8 @@ class Modbus():
__crc_tab = []
map = {
0x2007: {'reg': Register.MAX_DESIGNED_POWER, 'fmt': '!H', 'ratio': 1}, # noqa: E501
0x203e: {'reg': Register.NO_INPUTS, 'fmt': '!H', 'ratio': 1/256}, # noqa: E501
0x202c: {'reg': Register.OUTPUT_COEFFICIENT, 'fmt': '!H', 'ratio': 100/1024}, # noqa: E501
0x203e: {'reg': Register.NO_INPUTS, 'fmt': '!H', 'ratio': 1/256}, # noqa: E501

0x3000: {'reg': Register.INVERTER_STATUS, 'fmt': '!H'}, # noqa: E501
0x3008: {'reg': Register.VERSION, 'fmt': '!H', 'eval': "f'V{(result>>12)}.{(result>>8)&0xf}.{(result>>4)&0xf}{result&0xf:1X}'"}, # noqa: E501
Expand Down
17 changes: 16 additions & 1 deletion app/src/mqtt.py
Original file line number Diff line number Diff line change
Expand Up @@ -60,6 +60,7 @@ async def __loop(self) -> None:
interval = 5 # Seconds
ha_status_topic = f"{ha['auto_conf_prefix']}/status"
mb_rated_topic = "tsun/+/rated_load" # fixme
mb_out_coeff_topic = "tsun/+/out_coeff" # fixme
mb_reads_topic = "tsun/+/modbus_read_regs" # fixme
mb_inputs_topic = "tsun/+/modbus_read_inputs" # fixme
mb_at_cmd_topic = "tsun/+/at_cmd" # fixme
Expand All @@ -75,6 +76,7 @@ async def __loop(self) -> None:
# async with self.__client.messages() as messages:
await self.__client.subscribe(ha_status_topic)
await self.__client.subscribe(mb_rated_topic)
await self.__client.subscribe(mb_out_coeff_topic)
await self.__client.subscribe(mb_reads_topic)
await self.__client.subscribe(mb_inputs_topic)
await self.__client.subscribe(mb_at_cmd_topic)
Expand All @@ -93,6 +95,19 @@ async def __loop(self) -> None:
Modbus.WRITE_SINGLE_REG,
1, 0x2008)

if message.topic.matches(mb_out_coeff_topic):
payload = message.payload.decode("UTF-8")
val = round(float(payload) * 1024/100)

if val < 0 or val > 1024:
logger_mqtt.error('out_coeff: value must be in'
'the range 0..100,'
f' got: {payload}')
else:
await self.modbus_cmd(message,
Modbus.WRITE_SINGLE_REG,
0, 0x202c, val)

if message.topic.matches(mb_reads_topic):
await self.modbus_cmd(message,
Modbus.READ_REGS, 2)
Expand Down Expand Up @@ -154,7 +169,7 @@ async def modbus_cmd(self, message, func, params=0, addr=0, val=0):
logger_mqtt.debug(f'Found: {node_id}')
fnc = getattr(m, "send_modbus_cmd", None)
res = payload.split(',')
if params != len(res):
if params > 0 and params != len(res):
logger_mqtt.error(f'Parameter expected: {params}, '
f'got: {len(res)}')
return