mmc: sdhci: Reset cmd and data circuits after tuning failure
Browse files Browse the repository at this point in the history
To prevent subsequent commands failing, ensure the cmd and data circuits
are reset after a tuning timeout.

Signed-off-by: Adrian Hunter <[email protected]>
Signed-off-by: Ulf Hansson <[email protected]>
  • Loading branch information
ahunter6 authored and storulf committed Nov 7, 2016
1 parent 69b962a commit fe5fb2e
Showing 1 changed file with 4 additions and 0 deletions.
4 changes: 4 additions & 0 deletions drivers/mmc/host/sdhci.c
Original file line number Diff line number Diff line change
Expand Up @@ -2086,6 +2086,10 @@ static int sdhci_execute_tuning(struct mmc_host *mmc, u32 opcode)

if (!host->tuning_done) {
pr_info(DRIVER_NAME ": Timeout waiting for Buffer Read Ready interrupt during tuning procedure, falling back to fixed sampling clock\n");

sdhci_do_reset(host, SDHCI_RESET_CMD);
sdhci_do_reset(host, SDHCI_RESET_DATA);

ctrl = sdhci_readw(host, SDHCI_HOST_CONTROL2);
ctrl &= ~SDHCI_CTRL_TUNED_CLK;
ctrl &= ~SDHCI_CTRL_EXEC_TUNING;