Fix #857, correct interval calculation in DoSelect #898

Merged

Commits on Mar 12, 2021

  1. Fix nasa#857, correct interval calculation in DoSelect

    When calculating the relative time interval for the select() call,
    the increment should have been a decrement.
    
    This also adds a UT case that specifically exercises the carryover
    described.
    jphickey committed Mar 12, 2021