Interpretation of x(time.start) for delay buffer initialization #3733

@henrikt-ma

Description

@henrikt-ma

What is the value of y in the simulation of this model?

model DelayInitialization
  Real x(start = 1.0, fixed = true);
  Real y = delay(x, 5.0);
  discrete Real z;
initial equation
  z = y;
equation
  der(x) = 0.0;
  when not initial() then
    reinit(x, 2.0);
  end when;
  when false then
    z = 0.0;
  end when;
  annotation(experiment(StopTime = 1.0));
end DelayInitialization;

In System Modeler, the value is 1.0, but it could be argued that the specification says it should be 2.0.

The reason I also included z in the model is to highlight that we at least need to make the interpretation that x(0.0) actually simplifies to x in the initialization problem, and for me it would seem natural that this value is also the value used to initialize the delay buffer.

What is the value of x in other tools?