Unlock 0x8B5 register macro guard for SX162 - #9777
Merged
Merged
Conversation
3 tasks
Contributor
|
Seems like the log text should have been updated to not mention the specific GC1109 FEM too @thebentern |
Contributor
Author
Good call. I'll update the log too |
thebentern
pushed a commit
that referenced
this pull request
Apr 21, 2026
…ity (#10219) The CALIBRATE_ALL (0x7F) command inside resetAGC() clears bit 0 of the undocumented 0x8B5 register. That bit is set once in init() by #9571 and #9777 to improve SX1262 RX sensitivity, and the AGC-reset path was not re-applying it. Result: every SX1262 node silently loses the RX sensitivity patch ~60s after boot and never recovers until reboot. Empirically confirmed on Heltec Mesh Node T114 (nRF52840 + SX1262): - Post-calibration read of 0x8B5 = 0x04 (bit 0 cleared) - After re-apply: 0x05 (bit 0 set) Reproducible every AGC_RESET_INTERVAL_MS tick. Fix re-applies the register bit alongside the existing post-calibration re-applies (setDio2AsRfSwitch, setRxBoostedGainMode).
thebentern
pushed a commit
that referenced
this pull request
Apr 21, 2026
…ity (#10219) The CALIBRATE_ALL (0x7F) command inside resetAGC() clears bit 0 of the undocumented 0x8B5 register. That bit is set once in init() by #9571 and #9777 to improve SX1262 RX sensitivity, and the AGC-reset path was not re-applying it. Result: every SX1262 node silently loses the RX sensitivity patch ~60s after boot and never recovers until reboot. Empirically confirmed on Heltec Mesh Node T114 (nRF52840 + SX1262): - Post-calibration read of 0x8B5 = 0x04 (bit 0 cleared) - After re-apply: 0x05 (bit 0 set) Reproducible every AGC_RESET_INTERVAL_MS tick. Fix re-applies the register bit alongside the existing post-calibration re-applies (setDio2AsRfSwitch, setRxBoostedGainMode).
3 tasks
Evil8it
pushed a commit
to Evil8it/ME4TACTNK
that referenced
this pull request
Jun 10, 2026
…ity (meshtastic#10219) The CALIBRATE_ALL (0x7F) command inside resetAGC() clears bit 0 of the undocumented 0x8B5 register. That bit is set once in init() by meshtastic#9571 and meshtastic#9777 to improve SX1262 RX sensitivity, and the AGC-reset path was not re-applying it. Result: every SX1262 node silently loses the RX sensitivity patch ~60s after boot and never recovers until reboot. Empirically confirmed on Heltec Mesh Node T114 (nRF52840 + SX1262): - Post-calibration read of 0x8B5 = 0x04 (bit 0 cleared) - After re-apply: 0x05 (bit 0 set) Reproducible every AGC_RESET_INTERVAL_MS tick. Fix re-applies the register bit alongside the existing post-calibration re-applies (setDio2AsRfSwitch, setRxBoostedGainMode).
jeek
pushed a commit
to jeek/Meshtastic-Exploiteers-Hacker-Pager
that referenced
this pull request
Jun 30, 2026
Itzdavid01
pushed a commit
to Itzdavid01/firmware
that referenced
this pull request
Sep 5, 2026
Itzdavid01
pushed a commit
to Itzdavid01/firmware
that referenced
this pull request
Sep 5, 2026
…ity (meshtastic#10219) The CALIBRATE_ALL (0x7F) command inside resetAGC() clears bit 0 of the undocumented 0x8B5 register. That bit is set once in init() by meshtastic#9571 and meshtastic#9777 to improve SX1262 RX sensitivity, and the AGC-reset path was not re-applying it. Result: every SX1262 node silently loses the RX sensitivity patch ~60s after boot and never recovers until reboot. Empirically confirmed on Heltec Mesh Node T114 (nRF52840 + SX1262): - Post-calibration read of 0x8B5 = 0x04 (bit 0 cleared) - After re-apply: 0x05 (bit 0 set) Reproducible every AGC_RESET_INTERVAL_MS tick. Fix re-applies the register bit alongside the existing post-calibration re-applies (setDio2AsRfSwitch, setRxBoostedGainMode).
Itzdavid01
pushed a commit
to Itzdavid01/firmware
that referenced
this pull request
Sep 5, 2026
…ity (meshtastic#10219) The CALIBRATE_ALL (0x7F) command inside resetAGC() clears bit 0 of the undocumented 0x8B5 register. That bit is set once in init() by meshtastic#9571 and meshtastic#9777 to improve SX1262 RX sensitivity, and the AGC-reset path was not re-applying it. Result: every SX1262 node silently loses the RX sensitivity patch ~60s after boot and never recovers until reboot. Empirically confirmed on Heltec Mesh Node T114 (nRF52840 + SX1262): - Post-calibration read of 0x8B5 = 0x04 (bit 0 cleared) - After re-apply: 0x05 (bit 0 set) Reproducible every AGC_RESET_INTERVAL_MS tick. Fix re-applies the register bit alongside the existing post-calibration re-applies (setDio2AsRfSwitch, setRxBoostedGainMode).
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.