Skip to content

Unlock 0x8B5 register macro guard for SX162 - #9777

Merged
thebentern merged 1 commit into
masterfrom
open-register
Feb 28, 2026
Merged

Unlock 0x8B5 register macro guard for SX162#9777
thebentern merged 1 commit into
masterfrom
open-register

Conversation

@thebentern

Copy link
Copy Markdown
Contributor

No description provided.

@thebentern thebentern added enhancement New feature or request tech debt Code or lib references that are not up to date or propper standards labels Feb 28, 2026
@github-actions github-actions Bot added the needs-review Needs human review label Feb 28, 2026
@thebentern
thebentern merged commit 43aa90f into master Feb 28, 2026
22 of 68 checks passed
@thebentern
thebentern deleted the open-register branch February 28, 2026 14:38
@ndoo

ndoo commented Feb 28, 2026

Copy link
Copy Markdown
Contributor

Seems like the log text should have been updated to not mention the specific GC1109 FEM too @thebentern

@thebentern

Copy link
Copy Markdown
Contributor Author

Seems like the log text should have been updated to not mention the specific GC1109 FEM too @thebentern

Good call. I'll update the log too

thebentern pushed a commit that referenced this pull request Apr 21, 2026
…ity (#10219)

The CALIBRATE_ALL (0x7F) command inside resetAGC() clears bit 0 of the
undocumented 0x8B5 register. That bit is set once in init() by #9571 and
#9777 to improve SX1262 RX sensitivity, and the AGC-reset path was not
re-applying it. Result: every SX1262 node silently loses the RX
sensitivity patch ~60s after boot and never recovers until reboot.

Empirically confirmed on Heltec Mesh Node T114 (nRF52840 + SX1262):
  - Post-calibration read of 0x8B5 = 0x04 (bit 0 cleared)
  - After re-apply: 0x05 (bit 0 set)
Reproducible every AGC_RESET_INTERVAL_MS tick.

Fix re-applies the register bit alongside the existing post-calibration
re-applies (setDio2AsRfSwitch, setRxBoostedGainMode).
thebentern pushed a commit that referenced this pull request Apr 21, 2026
…ity (#10219)

The CALIBRATE_ALL (0x7F) command inside resetAGC() clears bit 0 of the
undocumented 0x8B5 register. That bit is set once in init() by #9571 and
#9777 to improve SX1262 RX sensitivity, and the AGC-reset path was not
re-applying it. Result: every SX1262 node silently loses the RX
sensitivity patch ~60s after boot and never recovers until reboot.

Empirically confirmed on Heltec Mesh Node T114 (nRF52840 + SX1262):
  - Post-calibration read of 0x8B5 = 0x04 (bit 0 cleared)
  - After re-apply: 0x05 (bit 0 set)
Reproducible every AGC_RESET_INTERVAL_MS tick.

Fix re-applies the register bit alongside the existing post-calibration
re-applies (setDio2AsRfSwitch, setRxBoostedGainMode).
Evil8it pushed a commit to Evil8it/ME4TACTNK that referenced this pull request Jun 10, 2026
…ity (meshtastic#10219)

The CALIBRATE_ALL (0x7F) command inside resetAGC() clears bit 0 of the
undocumented 0x8B5 register. That bit is set once in init() by meshtastic#9571 and
meshtastic#9777 to improve SX1262 RX sensitivity, and the AGC-reset path was not
re-applying it. Result: every SX1262 node silently loses the RX
sensitivity patch ~60s after boot and never recovers until reboot.

Empirically confirmed on Heltec Mesh Node T114 (nRF52840 + SX1262):
  - Post-calibration read of 0x8B5 = 0x04 (bit 0 cleared)
  - After re-apply: 0x05 (bit 0 set)
Reproducible every AGC_RESET_INTERVAL_MS tick.

Fix re-applies the register bit alongside the existing post-calibration
re-applies (setDio2AsRfSwitch, setRxBoostedGainMode).
jeek pushed a commit to jeek/Meshtastic-Exploiteers-Hacker-Pager that referenced this pull request Jun 30, 2026
Itzdavid01 pushed a commit to Itzdavid01/firmware that referenced this pull request Sep 5, 2026
Itzdavid01 pushed a commit to Itzdavid01/firmware that referenced this pull request Sep 5, 2026
…ity (meshtastic#10219)

The CALIBRATE_ALL (0x7F) command inside resetAGC() clears bit 0 of the
undocumented 0x8B5 register. That bit is set once in init() by meshtastic#9571 and
meshtastic#9777 to improve SX1262 RX sensitivity, and the AGC-reset path was not
re-applying it. Result: every SX1262 node silently loses the RX
sensitivity patch ~60s after boot and never recovers until reboot.

Empirically confirmed on Heltec Mesh Node T114 (nRF52840 + SX1262):
  - Post-calibration read of 0x8B5 = 0x04 (bit 0 cleared)
  - After re-apply: 0x05 (bit 0 set)
Reproducible every AGC_RESET_INTERVAL_MS tick.

Fix re-applies the register bit alongside the existing post-calibration
re-applies (setDio2AsRfSwitch, setRxBoostedGainMode).
Itzdavid01 pushed a commit to Itzdavid01/firmware that referenced this pull request Sep 5, 2026
…ity (meshtastic#10219)

The CALIBRATE_ALL (0x7F) command inside resetAGC() clears bit 0 of the
undocumented 0x8B5 register. That bit is set once in init() by meshtastic#9571 and
meshtastic#9777 to improve SX1262 RX sensitivity, and the AGC-reset path was not
re-applying it. Result: every SX1262 node silently loses the RX
sensitivity patch ~60s after boot and never recovers until reboot.

Empirically confirmed on Heltec Mesh Node T114 (nRF52840 + SX1262):
  - Post-calibration read of 0x8B5 = 0x04 (bit 0 cleared)
  - After re-apply: 0x05 (bit 0 set)
Reproducible every AGC_RESET_INTERVAL_MS tick.

Fix re-applies the register bit alongside the existing post-calibration
re-applies (setDio2AsRfSwitch, setRxBoostedGainMode).