78 changes: 32 additions & 46 deletions source/_components/climate.knx.markdown
Original file line number Diff line number Diff line change
Expand Up @@ -47,24 +47,19 @@ climate:
operation_mode_comfort_address: '5/1/7'
```

If you want to overwrite the supported operation modes use:
`operation_mode_frost_protection_address` / `operation_mode_night_address` / `operation_mode_comfort_address` are not necessary if `operation_mode_address` is specified.

```yaml
# Example configuration.yaml entry
climate:
- platform: knx
name: HASS-Kitchen.Temperature
temperature_address: '5/1/1'
setpoint_shift_address: '5/1/2'
setpoint_shift_state_address: '5/1/3'
target_temperature_address: '5/1/4'
operation_mode_frost_protection_address: '5/1/5'
operation_mode_comfort_address: '5/1/7'
override_supported_operation_modes:
- "Night"
- "Standby"
- "Comfort"
```
If your device doesn't support setpoint_shift calculations (i.e. if you don't provide a `setpoint_shift_address` value) please set the `min_temp` and `max_temp`
attributes of the climate device to avoid issues with increasing the temperature in the frontend.

The following values are valid for the `operation_modes` attribute:

- Comfort (maps internally to STATE_HEAT within Home Assistant)
- Standby (maps internally to STATE_ECO within Home Assistant)
- Night (maps internally to STATE_IDLE within Home Assistant)
- Frost Protection (maps internally to STATE_MANUAL within Home Assistant)
- Fan only (maps internally to STATE_FAN_ONLY within Home Assistant)
- Dehumidification (maps internally to STATE_DRY within Home Assistant)

{% configuration %}
name:
Expand Down Expand Up @@ -119,6 +114,14 @@ controller_status_state_address:
description: Explicit KNX address for reading HVAC controller status.
required: false
type: string
controller_mode_address:
description: KNX address for handling controller modes.
required: false
type: string
controller_mode_state_address:
description: Explicit KNX address for reading HVAC Control Mode.
required: false
type: string
operation_mode_frost_protection_address:
description: KNX address for switching on/off frost/heat protection mode.
required: false
Expand All @@ -131,41 +134,24 @@ operation_mode_comfort_address:
description: KNX address for switching on/off comfort mode.
required: false
type: string
override_supported_operation_modes:
description: Defines the supported operation modes.
operation_modes:
description: Overrides the supported operation modes.
required: false
Comment thread
MartinHjelmare marked this conversation as resolved.
type: array
on_off_address:
description: KNX address for switching the device on/off.
description: KNX address for switching the climate device on/off.
required: false
type: string
on_off_state_address:
description: Explicit KNX address for reading the current on/off status.
description: KNX address for gathering the current state (on/off) of the climate device.
required: false
type: string
min_temp:
description: Override the minimum temperature.
required: false
type: float
max_temp:
description: Override the maximum temperature.
required: false
type: float
{% endconfiguration %}

`operation_mode_frost_protection_address` / `operation_mode_night_address` / `operation_mode_comfort_address` are not necessary if `operation_mode_address` is specified.

`override_supported_operation_modes` is an array that can contain any of the following values:

- Auto
- Comfort
- Standby
- Night
- Frost Protection
- Heat
- Morning Warmup
- Cool
- Night Purge
- Precool
- Off
- Test
- Emergency Heat
- Fan only
- Ice
- Dry
- NoDem

Also check [this](https://github.com/XKNX/xknx/blob/master/xknx/knx/dpt_hvac_mode.py#L13-L30) page for more information.