96 changes: 96 additions & 0 deletions source/_integrations/growatt_server.markdown
Original file line number Diff line number Diff line change
Expand Up @@ -143,6 +143,102 @@ These controls directly modify your inverter's operational settings. Only change
- **AC charge**
- **Description**: Enable or disable AC charging

## Actions

The integration provides the following actions for managing Time-of-Use (TOU) battery schedules on MIN inverters:

### Action `growatt_server.update_time_segment`

Configure individual time segments (1-9) with battery operation mode, time range, and enable/disable state for automated battery charging and discharging schedules.

{% important %}
This action modifies your inverter's TOU scheduling settings. Incorrect configuration may affect your battery's charging/discharging behavior and energy costs. Ensure you understand your electricity tariff structure before making changes.
{% endimportant %}

**Data attributes:**

- **device_id** *(string, optional)*: The device ID of the inverter. Required only when multiple devices are present
- **segment_id** *(integer, required)*: Time segment number (1-9)
- **batt_mode** *(string, required)*: Energy priority mode for the system:
- `load_first`: Prioritize powering home loads from available energy sources (solar/battery), discharge battery when needed to meet home consumption
- `battery_first`: Prioritize charging the battery from available sources (solar/grid)
- `grid_first`: Prioritize exporting energy to grid from available sources (solar/battery), will discharge battery for grid export

{% note %}
The battery mode controls when and why discharge occurs. The actual discharge rate is controlled by the **Discharge power** number entity (0-100%).
{% endnote %}
- **start_time** *(time, required)*: Start time for the segment (HH:MM format)
- **end_time** *(time, required)*: End time for the segment (HH:MM format)
- **enabled** *(boolean, required)*: Whether this time segment is active

### Action `growatt_server.read_time_segments`

Read the current configuration of all 9 time segments from the inverter. This action returns the complete TOU schedule configuration.

**Data attributes:**

- **device_id** *(string, optional)*: The device ID of the MIN inverter. Required only when multiple devices are present

## Examples

### Off-peak charging schedule

Charge the battery during cheap electricity hours (e.g., midnight to 6 AM):

```yaml
action: growatt_server.update_time_segment
data:
segment_id: 1
batt_mode: "battery_first"
start_time: "00:00"
end_time: "06:00"
enabled: true
# For multiple devices, add device_id: "MIN12345"
```

{% note %}
Remember to also set the **Charge power** number entity (0-100%) to control the charging power rate during this time period.
{% endnote %}

### Peak hour export schedule

Export battery power to grid during expensive electricity hours (e.g., 4 PM to 8 PM):

```yaml
action: growatt_server.update_time_segment
data:
segment_id: 2
batt_mode: "grid_first"
start_time: "16:00"
end_time: "20:00"
enabled: true
```

{% note %}
Remember to also set the **Discharge power** number entity (0-100%) to control the discharge power rate during this time period.
{% endnote %}

### Daytime home priority schedule

Prioritize home consumption during typical usage hours (e.g., 6 AM to 10 PM):

```yaml
action: growatt_server.update_time_segment
data:
segment_id: 3
batt_mode: "load_first"
start_time: "06:00"
end_time: "22:00"
enabled: true
```

### Reading current TOU configuration

Check your current time segment settings:

```yaml
action: growatt_server.read_time_segments
```
## Troubleshooting

### Account locked or authentication failing
Expand Down