Encode prometheus metric names per the prom spec#26639
Merged
Merged
Conversation
Contributor
Referencing issue home-assistant#26418. Prometheus metric names can only contain chars a-zA-Z0-9, : and _ (https://prometheus.io/docs/concepts/data_model/#metric-names-and-labels). HA currently generates invalid prometheus names, e.g. if the unit for a sensor is a non-ASCII character containing ° or μ. To resolve, we need to sanitize the name before creating, replacing non-valid characters with a valid representation. In this case, I've used "u{unicode-hex-code}". Also updated the test case to make sure that the ° case is handled.
Member
|
Looks good to me. What do you think @perosb ? |
Contributor
|
makes sense, thanks @growse |
MartinHjelmare
approved these changes
Sep 14, 2019
Contributor
|
Any reasons why this wasn't merged yet and included in 0.99? I am eagerly waiting for this fix. |
balloob
pushed a commit
that referenced
this pull request
Sep 19, 2019
Referencing issue #26418. Prometheus metric names can only contain chars a-zA-Z0-9, : and _ (https://prometheus.io/docs/concepts/data_model/#metric-names-and-labels). HA currently generates invalid prometheus names, e.g. if the unit for a sensor is a non-ASCII character containing ° or μ. To resolve, we need to sanitize the name before creating, replacing non-valid characters with a valid representation. In this case, I've used "u{unicode-hex-code}". Also updated the test case to make sure that the ° case is handled.
Merged
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to subscribe to this conversation on GitHub.
Already have an account?
Sign in.
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Breaking Change:
Description:
Referencing issue #26418.
Prometheus metric names can only contain chars a-zA-Z0-9, : and _
(https://prometheus.io/docs/concepts/data_model/#metric-names-and-labels).
HA currently generates invalid prometheus names, e.g. if the unit for a
sensor is a non-ASCII character containing ° or μ. To resolve, we need
to sanitize the name before creating, replacing non-valid characters
with a valid representation. In this case, I've used
"u{unicode-hex-code}".
Also updated the test case to make sure that the ° case is handled.
Related issue (if applicable):
fixes #26418
Pull request with documentation for home-assistant.io (if applicable): home-assistant/home-assistant.io#<home-assistant.io PR number goes here>
Example entry for
configuration.yaml(if applicable):Checklist:
tox. Your PR cannot be merged unless tests passIf user exposed functionality or configuration variables are added/changed:
If the code communicates with devices, web services, or third-party tools:
python3 -m script.hassfest.requirements_all.txtby runningpython3 -m script.gen_requirements_all..coveragerc.If the code does not interact with devices: