$ gotip version
go version devel go1.20-6001c043dc Fri Aug 19 03:32:27 2022 +0000 linux/amd64
It's a small thing but I have encountered this by chance and I though I'd report it anyway, leaving for the compiler team to decide if it needs to be fixed.
Since unified was enabled by default, an internal compiler error can be triggered on manual invocations of go tool compile when there's mismatch between the package name as imported by main and the -p flag. Example:
$ tree
.
├── a.go
└── main.go
0 directories, 2 files
a.go
package a
func A() { println("a") }
main.go
package main
import "a"
func main() { a.A() }
Now:
$ gotip tool compile -p lie a.go <--- note the -p flag value
$ gotip tool compile -I=. -p main main.go
<unknown line number>: internal compiler error: have package "lie" (0xc0003dd130), want package "a" (0xc0003dcfa0)
goroutine 1 [running]:
runtime/debug.Stack()
/home/ZZZ/gotip/src/runtime/debug/stack.go:24 +0x65
cmd/compile/internal/base.FatalfAt({0x27005?, 0xc0?}, {0xd7c76d, 0x2a}, {0xc00011ca00, 0x4, 0x4})
/home/ZZZ/gotip/src/cmd/compile/internal/base/print.go:227 +0x1d7
cmd/compile/internal/base.Fatalf(...)
/home/ZZZ/gotip/src/cmd/compile/internal/base/print.go:196
cmd/compile/internal/base.Assertf(...)
/home/ZZZ/gotip/src/cmd/compile/internal/base/print.go:246
cmd/compile/internal/noder.readPackage(0xc000107860?, 0xc0003dcfa0?, 0x0?)
/home/ZZZ/gotip/src/cmd/compile/internal/noder/unified.go:260 +0x237
cmd/compile/internal/noder.readImportFile({0xc000027005?, 0xcec4a0?}, 0xc000000180, 0x7fa4029cc301?, 0xc0003cf140)
/home/ZZZ/gotip/src/cmd/compile/internal/noder/import.go:244 +0x727
cmd/compile/internal/noder.(*gcimports).ImportFrom(0x140aee0?, {0xc000027005?, 0xc000060c00?}, {0xc000027005?, 0x2?}, 0x40f26d?)
/home/ZZZ/gotip/src/cmd/compile/internal/noder/import.go:45 +0x3a
cmd/compile/internal/types2.(*Checker).importPackage(0xc000402000, {0xc0003ceff0, 0x3, 0x8}, {0xc000027005, 0x1}, {0xed11a0, 0x1})
/home/ZZZ/gotip/src/cmd/compile/internal/types2/resolver.go:144 +0x19e
cmd/compile/internal/types2.(*Checker).collectObjects(0xc000402000)
/home/ZZZ/gotip/src/cmd/compile/internal/types2/resolver.go:252 +0x1030
cmd/compile/internal/types2.(*Checker).checkFiles(0xc000402000, {0xc000012468, 0x1, 0x1})
/home/ZZZ/gotip/src/cmd/compile/internal/types2/check.go:321 +0x12c
cmd/compile/internal/types2.(*Checker).Files(...)
...
This doesn't happen with GOEXPERIMENT=nounified, and in fact a subsequent go tool link invocation appears to produce a working binary. unified may want to either follow the old behaviour (no errors) or report an error message instead of an ICE.
cc @mdempsky
Metadata
Metadata
Labels
FrozenDueToAgeNeedsFixThe path to resolution is known, but the work has not been done.The path to resolution is known, but the work has not been done.compiler/runtimeIssues related to the Go compiler and/or runtime.Issues related to the Go compiler and/or runtime.
Type
Projects
Status
Done