net: phy: broadcom: Fix auxiliary control register reads
Browse files Browse the repository at this point in the history
We are currently doing auxiliary control register reads with the shadow
register value 0b111 (0x7) which incidentally is also the selector value
that should be present in bits [2:0]. Fix this by using the appropriate
selector mask which is defined (MII_BCM54XX_AUXCTL_SHDWSEL_MASK).

This does not have a functional impact yet because we always access the
MII_BCM54XX_AUXCTL_SHDWSEL_MISC (0x7) register in the current code.
This might change at some point though.

Fixes: 5b4e290 ("net: phy: broadcom: add bcm54xx_auxctl_read")
Signed-off-by: Florian Fainelli <[email protected]>
Signed-off-by: David S. Miller <[email protected]>
  • Loading branch information
ffainelli authored and davem330 committed May 23, 2018
1 parent 2eabd76 commit 733a969
Showing 1 changed file with 1 addition and 1 deletion.
2 changes: 1 addition & 1 deletion drivers/net/phy/bcm-phy-lib.c
Original file line number Diff line number Diff line change
Expand Up @@ -56,7 +56,7 @@ int bcm54xx_auxctl_read(struct phy_device *phydev, u16 regnum)
/* The register must be written to both the Shadow Register Select and
* the Shadow Read Register Selector
*/
phy_write(phydev, MII_BCM54XX_AUX_CTL, regnum |
phy_write(phydev, MII_BCM54XX_AUX_CTL, MII_BCM54XX_AUXCTL_SHDWSEL_MASK |
regnum << MII_BCM54XX_AUXCTL_SHDWSEL_READ_SHIFT);
return phy_read(phydev, MII_BCM54XX_AUX_CTL);
}
Expand Down