20 changes: 16 additions & 4 deletions source/_integrations/generic_thermostat.markdown
Original file line number Diff line number Diff line change
Expand Up @@ -79,7 +79,15 @@ ac_mode:
type: boolean
default: false
min_cycle_duration:
description: Set a minimum amount of time that the switch specified in the *heater* option must be in its current state prior to being switched either off or on. This option will be ignored if the `keep_alive` option is set.
description: The minimum amount of time that must elapse before the switch specified in the *heater* option can be switched off.
required: false
type: [time, integer]
max_cycle_duration:
description: The maximum amount of time that can elapse before the switch specified in the *heater* option will be switched off.
required: false
type: [time, integer]
cycle_cooldown:
description: The minimum amount of time that must elapse before the switch specified in the *heater* option can be switched back on after being off.
required: false
type: [time, integer]
cold_tolerance:
Expand All @@ -93,7 +101,7 @@ hot_tolerance:
default: 0.3
type: float
keep_alive:
description: Set a keep-alive interval. If set, the switch specified in the *heater* option will be triggered every time the interval elapses. Use with heaters and A/C units that shut off if they don't receive a signal from their remote for a while. Use also with switches that might lose state. The keep-alive call is done with the current valid climate integration state (either on or off). When `keep_alive` is set the `min_cycle_duration` option will be ignored.
description: Set a keep-alive interval. If set, the switch specified in the *heater* option will be triggered every time the interval elapses. Use with heaters and A/C units that shut off if they don't receive a signal from their remote for a while. Use also with switches that might lose state. The keep-alive call is done with the current valid climate integration state (either on or off).
required: false
type: [time, integer]
initial_hvac_mode:
Expand Down Expand Up @@ -136,7 +144,7 @@ target_temp_step:
default: "equal to `precision`."
{% endconfiguration %}

Time for `min_cycle_duration` and `keep_alive` must be set as "hh:mm:ss" or it must contain at least one of the following entries: `days:`, `hours:`, `minutes:`, `seconds:` or `milliseconds:`. Alternatively, it can be an integer that represents time in seconds.
Time for `min_cycle_duration`, `max_cycle_duration`, `cycle_cooldown` and `keep_alive` must be set as "hh:mm:ss" or it must contain at least one of the following entries: `days:`, `hours:`, `minutes:`, `seconds:` or `milliseconds:`. Alternatively, it can be an integer that represents time in seconds. If both `min_cycle_duration` and `max_cycle_duration` are set, the time for `max_cycle_duration` must be greater than `min_cycle_duration`.

Currently the `generic_thermostat` climate platform supports 'heat', 'cool' and 'off' HVAC modes. You can force your `generic_thermostat` to avoid starting by setting HVAC mode to 'off'.

Expand All @@ -157,7 +165,11 @@ climate:
cold_tolerance: 0.3
hot_tolerance: 0
min_cycle_duration:
seconds: 5
minutes: 1
max_cycle_duration:
minutes: 10
cycle_cooldown:
seconds: 30
keep_alive:
minutes: 3
initial_hvac_mode: "off"