@Tyrbiter reported in #778 that he's occasionally getting "RX FIFO full" logging messages. Additional investigation indicated that this was because libpulse was queueing up huge boluses of samples in between long periods of being idle. This PR adds some additional logic to space out the incoming samples to prevent samples from being inappropriately dropped.