Replace the ESTOP 2 pin header with a locking connector like P901, P902 and P105.

I wouldn't want the ESTOP connector falling off during a job!

Note: I've populated mine with one already, but it sticks over the side <1mm. May require moving the connector slightly away from the edge of the board (room seems available).

@cefiar
Copy link
Contributor Author

cefiar commented Dec 12, 2013

Tracks moved and component placement have been changed. Header still needs to be changed to the right component.

bobc added a commit that referenced this issue Dec 18, 2013
#3 replace C301, C302, C303 and C501 with ceramic 0805;
#4 change endstop connectors to 6x1 and 6x2 to allow key position
#9 change E-STOP connector to KK type;
#18 add 10k pulldowns on heater outputs from CPU
#19 change E-STOP buffers to HCT type to always drive FETs at 5V and remove inverting drivers on heater outputs;
#20 add 24LC256 I2C EEPROM
bobc added a commit that referenced this issue Jan 3, 2014
locking conenctor for EM-STOP (#9);
add external 5V connector (#11)