Nexia

The nexia component lets you control thermostats connected to Nexia (Trane/American Standard).

As of version 1.0.0 this library uses asyncio and aiohttp. The last version to use requests was 0.9.13.

All the set functions are no coroutines.

Supported XL950, XL1050, XL824 Not supported XL624, others

By connecting this component, you will have access to all thermostats and zones in your associated home.

Concepts

The Nexia Thermostat supports the following key concepts.

RoomIQ Sensors

You can obtain sensor details in a Nexia Thermostat environment. The sensor data loaded during Nexia Home update are often out of date. So the Nexia Thermostat Zone service load_current_sensor_state is provided to load current sensor state into the physical thermostat. Many existing thermostat instance services will refresh this sensor data before completing. If no such service is desired, the Nexia Thermostat service refresh_thermostat_data is provided to refresh instance data. The Nexia Thermostat Zone service get_sensors is provided to obtain these sensor data in a list of sensor detail data objects of type NexiaSensor. To get a specific sensor detail data object, the Nexia Thermostat Zone service get_sensor_by_id is provided.

You can specify which RoomIQ sensors to include in the zone average via the Nexia Thermostat Zone service select_room_iq_sensors. You can see which RoomIQ sensors are included in the zone average via the Nexia Thermostat Zone service get_active_sensor_ids. To help coordinate separate manual actions taken to select active sensors you can use the Nexia RoomIQ Harmonizer services trigger_add_sensor, trigger_remove_sensor, request_pending, async_shutdown.

Attributes

The following attributes are provided by the Nexia Thermostat aux_heat, away_mode, current_humidity, current_temperature, fan_list, fan_mode, firmware, friendly_name, hold_mode, humidity, humidify_supported, dehumidify_supported, humidify_setpoint, dehumidify_setpoint max_humidity, max_temp, min_humidity, min_temp, model, operation_list, operation_mode, setpoint_status, target_temp_high, target_temp_low, target_temp_step, temperature, thermostat_id, thermostat_name, zone_id, zone_status

aux_heat

Indicates whether or not aux heat / emergency heat is enabled.

Attribute type Description
String 'on' or 'off'

away_mode

Indicates whether the 'away' preset is selected.

Attribute type Description
String 'on' or 'off'

Attribute current_humidity

Provides you with the main thermostat's relative humidity. Outdoor humidity or zone specific humidity is not currently available via Nexia's published data.

Attribute type Description
Float current humidity

Attribute current_temperature

Provides you with the current zone's temperature.

Attribute type Description
Integer current temperature

Attribute fan_list

This is a list of all available fan modes you can select, separated by commas.

Attribute type Description
String 'auto,on,circulate'

Attribute fan_mode

The currently selected fan mode.

Attribute type Description
String 'auto', 'on', or 'circulate'

Attribute firmware

Provides you with the current firmware version of the main thermostat.

Attribute type Description
String firmware version

Attribute hold_mode

Indicates if a hold is currently in place on this zone. Examples of such are 'away', 'home', 'sleep', or 'evening'

Attribute type Description
String hold mode

Attribute humidity

The target dehumidify set point (%) of the system.

Attribute type Description
Integer dehumidify setpoint as an integer

Attribute humidify_supported

Indicates if the system supports humidification.

Attribute type Description
Boolean humidification supported

Attribute dehumidify_supported

Indicates if the system supports dehumidification.

Attribute type Description
Boolean dehumidification supported

Attribute humidify_setpoint

The target humidify set point (%) of the system.

Attribute type Description
Integer humidify setpoint as an integer

Attribute dehumidify_setpoint

Same as humidity The target dehumidify set point (%) of the system.

Attribute type Description
Integer dehumidify setpoint as an integer

Attribute max_humidity

Hard-coded value indicating the maximum dehumidify set point (%) you can set, as an integer.

Attribute type Description
Integer maximum humidity set point, always 65

Attribute max_temp

The maximum temperature set point of the zone. This can change based on the thermostat's settings.

Attribute type Description
Integer maximum temperature, such as 90

Attribute min_humidity

Hard-coded value indicating the minimum dehumidify set point (%) you can set, as an integer.

Attribute type Description
Integer minimum humidity set point, always 10

Attribute min_temp

The minimum temperature set point of the zone. This can change based on the thermostat's settings.

Attribute type Description
Integer minimum temperature, such as 55

Attribute model

The thermostat model, such as 'TZON1050AC52ZAA'

Attribute type Description
String thermostat model

Attribute operation_list

List of available operation modes such as 'AUTO,COOL,HEAT,OFF'

Attribute type Description
String operation modes

Attribute operation_mode

The current operation mode, such as 'AUTO', 'COOL', 'HEAT', or 'OFF'

Attribute type Description
String operation mode

Attribute setpoint_status

This provides you with a system set point status, such as 'Holding Permanently', 'Following Schedule - Away', or 'Following Schedule - Home'. This is not an exhaustive list.

Attribute type Description
String set point status

Attribute target_temp_high

The target cooling (upper-bound) temperature for the current zone.

Attribute type Description
Integer upper-bound target temperature

Attribute target_temp_low

The target heating (lower-bound) temperature for the current zone.

Attribute type Description
Integer lower-bound target temperature

Attribute target_temp_step

The step at which the temperature can be increased or decreased. For Fahrenheit, this is 1.0 degrees per step, and for Celsius, this is 0.5 degrees per step.

Attribute type Description
Float step

Attribute temperature

Based on the current system mode, this is the target temperature for the zone.

Attribute type Description
Integer target temperature

Attribute thermostat_id

This is the main thermostat's ID, here for reference. This will match up with the 'id' in the JSON data provided by Nexia.

Attribute type Description
Integer thermostat ID

Attribute thermostat_name

The name of the system. This will be shared across all zones of your Trane / American Standard system.

Attribute type Description
String thermostat name

Attribute zone_id

The zone ID for this particular zone, here for reference. This will match up with the 'id' in the JSON data provided by Nexia under the 'zones' list.

Attribute type Description
Integer zone ID

Attribute zone_status

The status of the zone, such as 'Cooling', or 'Heating"

Attribute type Description
String zone status

NexiaHome Attributes

The following attribute is provided by the Nexia Home: log_response

Attribute log_response

An instance attribute of NexiaHome that controls logging http response text. This can be True or False. It is initialized to True and you can change it to False when you want to stop collecting http response text in your logs.

Attribute type Default Description
Boolean True response logging control

Services

The following climate services are provided by the Nexia Thermostat: set_aux_heat, set_away_mode, set_fan_mode, set_hold_mode, set_humidity, set_operation_mode, set_temperature, turn_on, turn_off

The service set_swing_mode offered by the Climate component is not implemented for this thermostat.

The following nexia climate service is provided by the Nexia Thermostat: set_aircleaner_mode

The following additional service is provided by the Nexia Thermostat: refresh_thermostat_data

Service refresh_thermostat_data

Refresh data in this thermostat instance. Note: Many other services refresh this data before completing, so you may not need to call this service to get fresh data. No arguments are passed to this service.

Service set_aux_heat

Enable the aux / emergency heat for the system. This is a system-wide setting.

Service data attribute Optional Description
entity_id yes String or list of strings that point at entity_id's of climate devices to control. Else targets all.
away_mode no 'on' or 'off'

Service set_away_mode

Turns the away mode on or off for the thermostat.

Service data attribute Optional Description
entity_id yes String or list of strings that point at entity_id's of climate devices to control. Else targets all.
away_mode no 'on' or 'off'

Service set_fan_mode

Sets the fan mode for the system. See the fan_list attribute for options. This is a system-wide setting.

Service data attribute Optional Description
entity_id yes String or list of strings that point at entity_id's of climate devices to control. Else targets all.
fan_mode no 'auto', 'on', or 'circulate'

Service set_hold_mode

Puts the thermostat into the given hold mode. For 'home', 'away', 'sleep', and any other hold based on a reference climate, the target temperature is taken from the reference climate.

Service data attribute Optional Description
entity_id yes String or list of strings that point at entity_id's of climate devices to control. Else targets all.
hold_mode no home, away, sleep

Service set_humidity

Sets the dehumidify set point of the system. Range from 35-65. This is a system-wide setting.

Service data attribute Optional Description
entity_id yes String or list of strings that point at entity_id's of climate devices to control. Else targets all.
humidity no The dehumidify setpoint, like 50.

Service set_temperature

Puts the thermostat into a temporary hold at the given temperature.

Service data attribute Optional Description
entity_id yes String or list of strings that point at entity_id's of climate devices to control. Else targets all.
target_temp_low no Desired heating target temperature (when in auto mode)
target_temp_high no Desired cooling target temperature (when in auto mode)
temperature no Desired target temperature (when not in auto mode)

Only the target temperatures relevant for the current operation mode need to be provided.

Service set_operation_mode

Sets the current operation mode of the thermostat. See attribute operation_list for options.

Service data attribute Optional Description
entity_id yes String or list of strings that point at entity_id's of climate devices to control. Else targets all.
operation_mode no 'AUTO', 'COOL', 'HEAT', or 'OFF'

Service turn_on

Turns the zone on.

Service data attribute Optional Description
entity_id yes String or list of strings that point at entity_id's of climate devices to control. Else targets all.

Service turn_off

Turns the zone off.

Service data attribute Optional Description
entity_id yes String or list of strings that point at entity_id's of climate devices to control. Else targets all.

Service set_aircleaner_mode

Part of the nexia. services. Sets the air cleaner mode. Options include 'AUTO', 'QUICK', and 'ALLERGY'. This is a system-wide setting.

Service data attribute Optional Description
entity_id yes String or list of strings that point at entity_id's of climate devices to control. Else targets all.
aircleaner_mode no 'AUTO', 'QUICK', or 'ALLERGY'

Service set_humidify_setpoint

Part of the nexia. services. Sets the humidify setpoint. This is a system-wide setting.

Service data attribute Optional Description
entity_id yes String or list of strings that point at entity_id's of climate devices to control. Else targets all.
humidity no Humidify setpoint level, from 10 to 65.

NexiaThermostatZone Services

The following services are provided by the Nexia Thermostat Zone: get_sensors, get_active_sensor_ids, get_sensor_by_id, select_room_iq_sensors, load_current_sensor_state

Service get_sensors

Get the sensor detail data objects from this zone instance. Provides a list of sensor detail data objects available in this zone. No arguments are passed to this service.

Service get_active_sensor_ids

Get the set of RoomIQ sensor ids included in the zone average. Provides a set of active RoomIQ sensor ids. No arguments are passed to this service.

Service get_sensor_by_id

Get a RoomIQ sensor detail data object by its sensor identifier. Valid identifiers come from the sensor detail data objects returned from get_sensors. Provides a specific sensor detail data object from this zone instance.

Service data attribute Optional Description
sensor_id no identifier of RoomIQ sensor to get

Service select_room_iq_sensors

Specify which RoomIQ sensors to include in the zone average. RoomIQ sensors not given to this service are not included. You specify which sensors to include by supplying a collection of RoomIQ sensor identifiers. Valid identifiers come from the sensor detail data objects returned from get_sensors. This service returns a bool indicating if it completed successfully.

Service data attribute Optional Default Description
active_sensor_ids no collection of RoomIQ sensor identifiers to form the zone average
polling_delay yes 5.0 seconds to wait before each polling attempt
max_polls yes 8 maximum number of times to poll for completion

Service load_current_sensor_state

Load the current state of a zone's sensors into the physical thermostat. Note: This service does not update data in this zone instance - many of the thermostat services do so. This service returns a bool indicating if it completed successfully.

Service data attribute Optional Default Description
polling_delay yes 5.0 seconds to wait before each polling attempt
max_polls yes 8 maximum number of times to poll for completion

NexiaRoomIQHarmonizer Services

The Nexia RoomIQ Harmonizer controller tracks which RoomIQ sensors are to be selected for a zone and makes the selection after inactivity. This helps coordinate separate manual actions taken to select active sensors. The following services are provided by the Nexia RoomIQ Harmonizer: trigger_add_sensor, trigger_remove_sensor, request_pending, async_shutdown

To construct a NexiaRoomIQHarmonizer object, the following parameters apply.

Service data attribute Optional Default Description
zone no zone to control
async_request_refetch no coroutine to request a refetch of zone status
signal_updated no function to signal that our state has changed
after_last_change_seconds yes 4.0 seconds to delay before selecting sensors

Service trigger_add_sensor

Trigger selecting the specified sensor for the zone.

Service data attribute Optional Default Description
sensor_id no identifier of the sensor to add to the zone's selection

Service trigger_remove_sensor

Trigger removing the specified sensor from the zone selection.

Service data attribute Optional Default Description
sensor_id no identifier of the sensor to remove from the zone's selection

Service request_pending

Return if a triggered sensor selection is pending. No arguments are passed to this service.

Service async_shutdown

Clean up before stopping. No arguments are passed to this service.