@@ -50,10 +50,10 @@ There is a conflict of thrift version between IoTDB and Spark.Therefore, you nee | |
|
|
||
| | Name | Type | Required | Default | Description | | ||
| |-----------------------------|---------|----------|--------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------| | ||
| | node_urls | Array | Yes | - | `IoTDB` cluster address, the format is `["host:port", ...]` | | ||
| | node_urls | String | Yes | - | `IoTDB` cluster address, the format is `"host1:port"` or `"host1:port,host2:port"` | | ||
| | username | String | Yes | - | `IoTDB` user username | | ||
| | password | String | Yes | - | `IoTDB` user password | | ||
| | key_device | String | No | - | Specify field name of the `IoTDB` deviceId in SeaTunnelRow | | ||
| | key_device | String | Yes | - | Specify field name of the `IoTDB` deviceId in SeaTunnelRow | | ||
| | key_timestamp | String | No | processing time | Specify field-name of the `IoTDB` timestamp in SeaTunnelRow. If not specified, use processing-time as timestamp | | ||
| | key_measurement_fields | Array | No | exclude `device` & `timestamp` | Specify field-name of the `IoTDB` measurement list in SeaTunnelRow. If not specified, include all fields but exclude `device` & `timestamp` | | ||
| | storage_group | Array | No | - | Specify device storage group(path prefix) <br/> example: deviceId = ${storage_group} + "." + ${key_device} | | ||
|
|
@@ -68,78 +68,124 @@ There is a conflict of thrift version between IoTDB and Spark.Therefore, you nee | |
| | connection_timeout_in_ms | Integer | No | - | The maximum time (in ms) to wait when connecting to `IoTDB` | | ||
| | common-options | | no | - | Sink plugin common parameters, please refer to [Sink Common Options](common-options.md) for details | | ||
|
|
||
| ## Task Example | ||
| ## Examples | ||
|
|
||
| ```hocon | ||
| env { | ||
| execution.parallelism = 2 | ||
| job.mode = "BATCH" | ||
| } | ||
|
|
||
| source { | ||
| FakeSource { | ||
| row.num = 16 | ||
| bigint.template = [1664035200001] | ||
| schema = { | ||
| fields { | ||
| device_name = "string" | ||
| temperature = "float" | ||
| moisture = "int" | ||
| event_ts = "bigint" | ||
| c_string = "string" | ||
| c_boolean = "boolean" | ||
| c_tinyint = "tinyint" | ||
| c_smallint = "smallint" | ||
| c_int = "int" | ||
| c_bigint = "bigint" | ||
| c_float = "float" | ||
| c_double = "double" | ||
| } | ||
| } | ||
| } | ||
| } | ||
|
|
||
| ... | ||
|
|
||
| ``` | ||
|
|
||
| Upstream SeaTunnelRow data format is the following: | ||
|
|
||
| | device_name | temperature | moisture | event_ts | c_string | c_boolean | c_tinyint | c_smallint | c_int | c_bigint | c_float | c_double | | ||
| |--------------------------|-------------|----------|---------------|----------|-----------|-----------|------------|-------|------------|---------|----------| | ||
| | root.test_group.device_a | 36.1 | 100 | 1664035200001 | abc1 | true | 1 | 1 | 1 | 2147483648 | 1.0 | 1.0 | | ||
| | root.test_group.device_b | 36.2 | 101 | 1664035200001 | abc2 | false | 2 | 2 | 2 | 2147483649 | 2.0 | 2.0 | | ||
| | root.test_group.device_c | 36.3 | 102 | 1664035200001 | abc3 | false | 3 | 3 | 3 | 2147483649 | 3.0 | 3.0 | | ||
|
|
||
| ### Case1 | ||
|
|
||
| Common options: | ||
| only fill required config. | ||
| use current processing time as timestamp. and include all fields but exclude `device` & `timestamp` as measurement fields | ||
|
|
||
| ```hocon | ||
| sink { | ||
| IoTDB { | ||
| node_urls = ["localhost:6667"] | ||
| node_urls = "localhost:6667" | ||
| username = "root" | ||
| password = "root" | ||
| batch_size = 1024 | ||
| key_device = "device_name" | ||
| } | ||
| } | ||
| ``` | ||
|
|
||
| When you assign `key_device` is `device_name`, for example: | ||
| Output to `IoTDB` data format is the following: | ||
|
|
||
| ```shell | ||
| IoTDB> SELECT * FROM root.test_group.* align by device; | ||
| +------------------------+------------------------+--------------+-----------+--------------+---------+----------+----------+-----------+------+-----------+--------+---------+ | ||
| | Time| Device| temperature| moisture| event_ts| c_string| c_boolean| c_tinyint| c_smallint| c_int| c_bigint| c_float| c_double| | ||
| +------------------------+------------------------+--------------+-----------+--------------+---------+----------+----------+-----------+------+-----------+--------+---------+ | ||
| |2023-09-01T00:00:00.001Z|root.test_group.device_a| 36.1| 100| 1664035200001| abc1| true| 1| 1| 1| 2147483648| 1.0| 1.0| | ||
| |2023-09-01T00:00:00.001Z|root.test_group.device_b| 36.2| 101| 1664035200001| abc2| false| 2| 2| 2| 2147483649| 2.0| 2.0| | ||
| |2023-09-01T00:00:00.001Z|root.test_group.device_c| 36.3| 102| 1664035200001| abc2| false| 3| 3| 3| 2147483649| 3.0| 3.0| | ||
| +------------------------+------------------------+--------------+-----------+--------------+---------+---------+-----------+-----------+------+-----------+--------+---------+ | ||
| ``` | ||
|
|
||
| ### Case2 | ||
|
|
||
| use source event's time | ||
|
|
||
| ```hocon | ||
| sink { | ||
| IoTDB { | ||
| ... | ||
| node_urls = "localhost:6667" | ||
| username = "root" | ||
| password = "root" | ||
| key_device = "device_name" | ||
| key_timestamp = "event_ts" | ||
|
liunaijie marked this conversation as resolved.
Outdated
|
||
| } | ||
| } | ||
| ``` | ||
|
|
||
| Upstream SeaTunnelRow data format is the following: | ||
|
Member
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. why delete?
Member
Author
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. the sink example, I only add 1 case (fakesource to iotdb)(also 1 case in source example, use iotdb to console) the key_timestamp is optional, so i remove it. |
||
|
|
||
| | device_name | field_1 | field_2 | | ||
| |--------------------------|---------|---------| | ||
| | root.test_group.device_a | 1001 | 1002 | | ||
| | root.test_group.device_b | 2001 | 2002 | | ||
| | root.test_group.device_c | 3001 | 3002 | | ||
|
|
||
| Output to `IoTDB` data format is the following: | ||
|
|
||
| ```shell | ||
| IoTDB> SELECT * FROM root.test_group.* align by device; | ||
| +------------------------+------------------------+-----------+----------+ | ||
| | Time| Device| field_1| field_2| | ||
| +------------------------+------------------------+----------+-----------+ | ||
| |2022-09-26T17:50:01.201Z|root.test_group.device_a| 1001| 1002| | ||
| |2022-09-26T17:50:01.202Z|root.test_group.device_b| 2001| 2002| | ||
| |2022-09-26T17:50:01.203Z|root.test_group.device_c| 3001| 3002| | ||
| +------------------------+------------------------+----------+-----------+ | ||
| +------------------------+------------------------+--------------+-----------+--------------+---------+----------+----------+-----------+------+-----------+--------+---------+ | ||
| | Time| Device| temperature| moisture| event_ts| c_string| c_boolean| c_tinyint| c_smallint| c_int| c_bigint| c_float| c_double| | ||
| +------------------------+------------------------+--------------+-----------+--------------+---------+----------+----------+-----------+------+-----------+--------+---------+ | ||
| |2022-09-25T00:00:00.001Z|root.test_group.device_a| 36.1| 100| 1664035200001| abc1| true| 1| 1| 1| 2147483648| 1.0| 1.0| | ||
| |2022-09-25T00:00:00.001Z|root.test_group.device_b| 36.2| 101| 1664035200001| abc2| false| 2| 2| 2| 2147483649| 2.0| 2.0| | ||
| |2022-09-25T00:00:00.001Z|root.test_group.device_c| 36.3| 102| 1664035200001| abc2| false| 3| 3| 3| 2147483649| 3.0| 3.0| | ||
| +------------------------+------------------------+--------------+-----------+--------------+---------+---------+-----------+-----------+------+-----------+--------+---------+ | ||
| ``` | ||
|
|
||
| ### Case2 | ||
| ### Case3 | ||
|
|
||
| When you assign `key_device`、`key_timestamp`、`key_measurement_fields`, for example: | ||
| use source event's time and limit measurement fields | ||
|
|
||
| ```hocon | ||
| sink { | ||
| IoTDB { | ||
| ... | ||
| node_urls = "localhost:6667" | ||
| username = "root" | ||
| password = "root" | ||
| key_device = "device_name" | ||
| key_timestamp = "ts" | ||
|
Member
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. why delete? |
||
| key_timestamp = "event_ts" | ||
| key_measurement_fields = ["temperature", "moisture"] | ||
| } | ||
| } | ||
| ``` | ||
|
|
||
| Upstream SeaTunnelRow data format is the following: | ||
|
|
||
| | ts | device_name | field_1 | field_2 | temperature | moisture | | ||
|
Member
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. whl update ? |
||
| |---------------|--------------------------|---------|---------|-------------|----------| | ||
| | 1664035200001 | root.test_group.device_a | 1001 | 1002 | 36.1 | 100 | | ||
| | 1664035200001 | root.test_group.device_b | 2001 | 2002 | 36.2 | 101 | | ||
| | 1664035200001 | root.test_group.device_c | 3001 | 3002 | 36.3 | 102 | | ||
|
|
||
| Output to `IoTDB` data format is the following: | ||
|
|
||
| ```shell | ||
|
|
||
Uh oh!