Skip to content

Releases: Wiznet/WIZ750SR

1.4.0 Stable

19 Mar 06:55
686df2e
Compare
Choose a tag to compare

Attached binaries

  • WIZ750SR-TTL / RS232 / RS485

    • WIZ750SRv140.bin (App only)
    • WIZ750SRv140_incl_Boot.bin (Boot+App)
  • WIZ750SR-100 / 105 / 110

    • WIZ750SR-1xxv140.bin (App only)
    • WIZ750SR-1xxv140_incl_Boot.bin (Boot+App)

* WIZnet S2E config-tool supports firmware update function of application area only. (App only) If you want to program the 'Boot+App' firmware on your device, please use the W7500(P) ISP tool.


  • Improvements:
    • Add watchdog function
    • Add Config WebServer
    • Include http parser issue fix in ioLibrary

1.3.3 Stable

13 Dec 07:31
Compare
Choose a tag to compare

Attached binaries

  • WIZ750SR-TTL / RS232 / RS485

    • WIZ750SRv133.bin (App only)
    • WIZ750SRv133_incl_Boot.bin (Boot+App)
  • WIZ750SR-100 / 105 / 110

    • WIZ750SR-1xxv133.bin (App only)
    • WIZ750SR-1xxv133_incl_Boot.bin (Boot+App)

* WIZnet S2E config-tool supports firmware update function of application area only. (App only) If you want to program the 'Boot+App' firmware on your device, please use the W7500(P) ISP tool.


  • Improvements:
    • Added in order to remove some unused functions
    • Modified the start ISR address from 0x1fd00 to 0x7d00
    • Modified flag of socket when socket function use(Non Block)

1.2.9 Stable

13 Dec 07:32
Compare
Choose a tag to compare

Attached binaries

  • WIZ750SR-TTL / RS232 / RS485

    • WIZ750SRv129.bin (App only)
    • WIZ750SRv129_incl_Boot.bin (Boot+App)
  • WIZ750SR-100 / 105 / 110

    • WIZ750SR-1xxv129.bin (App only)
    • WIZ750SR-1xxv129_incl_Boot.bin (Boot+App)

* WIZnet S2E config-tool supports firmware update function of application area only. (App only) If you want to program the 'Boot+App' firmware on your device, please use the W7500(P) ISP tool.


  • Improvements:
    • Added in order to remove some unused functions
    • Modified flag of socket when socket function use(Non Block)

1.3.2 Stable

03 Dec 04:18
Compare
Choose a tag to compare

Attached binaries

  • WIZ750SR-TTL / RS232 / RS485

    • WIZ750SRv132.bin (App only)
    • WIZ750SRv132_incl_Boot.bin (Boot+App)
  • WIZ750SR-100 / 105

    • WIZ750SR-10xv132.bin (App only)
    • WIZ750SR-10xv132_incl_Boot.bin (Boot+App)
  • WIZ750SR-110

    • WIZ750SR-110v132.bin (App only)
    • WIZ750SR-110v132_incl_Boot.bin (Boot+App)

* WIZnet S2E config-tool supports firmware update function of application area only. (App only) If you want to program the 'Boot+App' firmware on your device, please use the W7500(P) ISP tool.


  • Bug fixes:
    • Fixed the pin mapping :
      DSR pin of WIZ750SR-100/105/110

1.2.8 Stable

03 Dec 04:15
Compare
Choose a tag to compare

Attached binaries

  • WIZ750SR-TTL / RS232 / RS485

    • WIZ750SRv128.bin (App only)
    • WIZ750SRv128_incl_Boot.bin (Boot+App)
  • WIZ750SR-100 / 105

    • WIZ750SR-10xv128.bin (App only)
    • WIZ750SR-10xv128_incl_Boot.bin (Boot+App)
  • WIZ750SR-110

    • WIZ750SR-110v128.bin (App only)
    • WIZ750SR-110v128_incl_Boot.bin (Boot+App)

* WIZnet S2E config-tool supports firmware update function of application area only. (App only) If you want to program the 'Boot+App' firmware on your device, please use the W7500(P) ISP tool.


  • Fixing bugs as follow:
    • Fixed Exception routine(Class C private IP) :
      When the module IP and Remote IP is 192.168.xx.xx and third ip is different for each, ARP request operation is not transmitted.(This part had deleted)
    • Fixed the pin mapping :
      DSR pin of WIZ750SR-100/105/110

1.3.1Stable

22 Nov 07:50
Compare
Choose a tag to compare

Attached binaries

  • WIZ750SR-TTL / RS232 / RS485

    • WIZ750SRv131.bin (App only)
    • WIZ750SRv131_incl_Boot.bin (Boot+App)
  • WIZ750SR-100 / 105

    • WIZ750SR-10xv131.bin (App only)
    • WIZ750SR-10xv131_incl_Boot.bin (Boot+App)
  • WIZ750SR-110

    • WIZ750SR-110v131.bin (App only)
    • WIZ750SR-110v131_incl_Boot.bin (Boot+App)

* WIZnet S2E config-tool supports firmware update function of application area only. (App only) If you want to program the 'Boot+App' firmware on your device, please use the W7500(P) ISP tool.


  • Bug fixes:
    • When exception situation of TCP Connection - Class C private IP
      When the module IP and Remote IP is 192.168.xx.xx and third ip is different for each, ARP request operation is not transmitted.(This part had deleted)

1.3.0 Stable

22 Nov 07:43
Compare
Choose a tag to compare

Attached binaries

  • WIZ750SR-TTL / RS232 / RS485

    • WIZ750SRv130.bin (App only)
    • WIZ750SRv130_incl_Boot.bin (Boot+App)
  • WIZ750SR-100 / 105

    • WIZ750SR-10xv130.bin (App only)
    • WIZ750SR-10xv130_incl_Boot.bin (Boot+App)
  • WIZ750SR-110

    • WIZ750SR-110v130.bin (App only)
    • WIZ750SR-110v130_incl_Boot.bin (Boot+App)

* WIZnet S2E config-tool supports firmware update function of application area only. (App only) If you want to program the 'Boot+App' firmware on your device, please use the W7500(P) ISP tool.


  • Bug fixes:
    • When APP firmware is uploading using the configuration Tool and Board is power off, the product not operate.
    • DHCP Lease Time : when DHCP_DEBUG enable, DHCP Lease Time is fixed as 10 second.
      • DHCP lease time is modified to use it that information of received packet from DHCP Server.
    • The Status LED(PA_07) of WIZ750SR_1xx doesn't operate.
      • The Status LED(PA_07) of WIZ750SR_1xx is modified. Turning on an LED and making it blink once per second.
    • Compare DHCP Server IP : When DHCP OFFER Packet receive from DHCP Server,the DHCP server ip in packet compare with previous DHCP Server IP.
  • Improvements:
    • The ISR address have changed to fixed address. The ISR address of APP did no more have to need copy and use in Boot.

1.2.6 Stable

15 Oct 02:34
Compare
Choose a tag to compare

Attached binaries

  • WIZ750SR-TTL / RS232 / RS485

    • WIZ750SRv126.bin (App only)
    • WIZ750SRv126_incl_Boot.bin (Boot+App)
  • WIZ750SR-100 / 105

    • WIZ750SR-10xv126.bin (App only)
    • WIZ750SR-10xv126_incl_Boot.bin (Boot+App)
  • WIZ750SR-110

    • WIZ750SR-110v126.bin (App only)
    • WIZ750SR-110v126_incl_Boot.bin (Boot+App)

* WIZnet S2E config-tool supports firmware update function of application area only. (App only) If you want to program the 'Boot+App' firmware on your device, please use the W7500(P) ISP tool.


  • Bug fixes:

    • If serial data packing 'time' option is less than 500ms, the first serial data(+++) ignored in GW mode.
    • When UART Tx/RX cross connect and Received UART data size more than 3, UART data don't send .
  • Improvements:

    • While IP address is allocating using DHCP ,
      • the device can be made searchable using the Configuration tool and it can change the mode(AT mode <-> GW mode).
        • It can change the AT mode. It can show that the status of channel change from ATmode to OPEN in Configuration tool. So AT command didn't operate and this bug fixed

1.2.5 Stable

20 Sep 02:02
2b5df7f
Compare
Choose a tag to compare

Attached binaries

  • WIZ750SR-TTL / RS232 / RS485

    • WIZ750SRv125.bin (App only)
    • WIZ750SRv125_incl_Boot.bin (Boot+App)
  • WIZ750SR-100 / 105

    • WIZ750SR-10xv125.bin (App only)
    • WIZ750SR-10xv125_incl_Boot.bin (Boot+App)
  • WIZ750SR-110

    • WIZ750SR-110v125.bin (App only)
    • WIZ750SR-110v125_incl_Boot.bin (Boot+App)

* WIZnet S2E config-tool supports firmware update function of application area only. (App only) If you want to program the 'Boot+App' firmware on your device, please use the W7500(P) ISP tool.


Bug fixes:

  • Modyfied the setSn_DHAR() Address offset.
  • Modyfied the WIZ750SR-110 HW_Trigger pin.

Improvements:

  • If remote ip address is multicast address, enable multicating and set Sn_DHAR, Sn_DIPR, Sn_DPORTR before open socket

v1.2.4 Stable

22 Jun 08:01
dbffe04
Compare
Choose a tag to compare

Attached binaries

  • WIZ750SR-TTL / RS232 / RS485

    • WIZ750SRv124.bin (App only)
    • WIZ750SRv124_incl_Boot.bin (Boot+App)
  • WIZ750SR-100 / 105 / 110

    • WIZ750SR-1xxv124.bin (App only)
    • WIZ750SR-1xxv124_incl_Boot.bin (Boot+App)

* WIZnet S2E config-tool supports firmware update function of application area only. (App only) If you want to program the 'Boot+App' firmware on your device, please use the W7500(P) ISP tool.


Bug fixes:

  • Serial data packing 'time' option does not work if serial command mode switching code is disabled.
  • Fix typo of debug message

Improvements:

  • Added the PHY init stabilization code
  • Restore TCP connection status function to Status Pin (WIZ750SR-100/105/110 only)
    • The Status pin now acts as an 'HW_Trigger' pin(Input at booting) and a TCP connection status pin(output).