Releases: Wiznet/WIZ750SR
1.4.0 Stable
Attached binaries
-
WIZ750SR-TTL / RS232 / RS485
- WIZ750SRv140.bin (App only)
- WIZ750SRv140_incl_Boot.bin (Boot+App)
-
WIZ750SR-100 / 105 / 110
- WIZ750SR-1xxv140.bin (App only)
- WIZ750SR-1xxv140_incl_Boot.bin (Boot+App)
* WIZnet S2E config-tool supports firmware update function of application area only. (App only) If you want to program the 'Boot+App' firmware on your device, please use the W7500(P) ISP tool.
- Improvements:
- Add watchdog function
- Add Config WebServer
- Include http parser issue fix in ioLibrary
1.3.3 Stable
Attached binaries
-
WIZ750SR-TTL / RS232 / RS485
- WIZ750SRv133.bin (App only)
- WIZ750SRv133_incl_Boot.bin (Boot+App)
-
WIZ750SR-100 / 105 / 110
- WIZ750SR-1xxv133.bin (App only)
- WIZ750SR-1xxv133_incl_Boot.bin (Boot+App)
* WIZnet S2E config-tool supports firmware update function of application area only. (App only) If you want to program the 'Boot+App' firmware on your device, please use the W7500(P) ISP tool.
- Improvements:
- Added in order to remove some unused functions
- Modified the start ISR address from 0x1fd00 to 0x7d00
- Modified flag of socket when socket function use(Non Block)
1.2.9 Stable
Attached binaries
-
WIZ750SR-TTL / RS232 / RS485
- WIZ750SRv129.bin (App only)
- WIZ750SRv129_incl_Boot.bin (Boot+App)
-
WIZ750SR-100 / 105 / 110
- WIZ750SR-1xxv129.bin (App only)
- WIZ750SR-1xxv129_incl_Boot.bin (Boot+App)
* WIZnet S2E config-tool supports firmware update function of application area only. (App only) If you want to program the 'Boot+App' firmware on your device, please use the W7500(P) ISP tool.
- Improvements:
- Added in order to remove some unused functions
- Modified flag of socket when socket function use(Non Block)
1.3.2 Stable
Attached binaries
-
WIZ750SR-TTL / RS232 / RS485
- WIZ750SRv132.bin (App only)
- WIZ750SRv132_incl_Boot.bin (Boot+App)
-
WIZ750SR-100 / 105
- WIZ750SR-10xv132.bin (App only)
- WIZ750SR-10xv132_incl_Boot.bin (Boot+App)
-
WIZ750SR-110
- WIZ750SR-110v132.bin (App only)
- WIZ750SR-110v132_incl_Boot.bin (Boot+App)
* WIZnet S2E config-tool supports firmware update function of application area only. (App only) If you want to program the 'Boot+App' firmware on your device, please use the W7500(P) ISP tool.
- Bug fixes:
- Fixed the pin mapping :
DSR pin of WIZ750SR-100/105/110
- Fixed the pin mapping :
1.2.8 Stable
Attached binaries
-
WIZ750SR-TTL / RS232 / RS485
- WIZ750SRv128.bin (App only)
- WIZ750SRv128_incl_Boot.bin (Boot+App)
-
WIZ750SR-100 / 105
- WIZ750SR-10xv128.bin (App only)
- WIZ750SR-10xv128_incl_Boot.bin (Boot+App)
-
WIZ750SR-110
- WIZ750SR-110v128.bin (App only)
- WIZ750SR-110v128_incl_Boot.bin (Boot+App)
* WIZnet S2E config-tool supports firmware update function of application area only. (App only) If you want to program the 'Boot+App' firmware on your device, please use the W7500(P) ISP tool.
- Fixing bugs as follow:
- Fixed Exception routine(Class C private IP) :
When the module IP and Remote IP is 192.168.xx.xx and third ip is different for each, ARP request operation is not transmitted.(This part had deleted) - Fixed the pin mapping :
DSR pin of WIZ750SR-100/105/110
- Fixed Exception routine(Class C private IP) :
1.3.1Stable
Attached binaries
-
WIZ750SR-TTL / RS232 / RS485
- WIZ750SRv131.bin (App only)
- WIZ750SRv131_incl_Boot.bin (Boot+App)
-
WIZ750SR-100 / 105
- WIZ750SR-10xv131.bin (App only)
- WIZ750SR-10xv131_incl_Boot.bin (Boot+App)
-
WIZ750SR-110
- WIZ750SR-110v131.bin (App only)
- WIZ750SR-110v131_incl_Boot.bin (Boot+App)
* WIZnet S2E config-tool supports firmware update function of application area only. (App only) If you want to program the 'Boot+App' firmware on your device, please use the W7500(P) ISP tool.
- Bug fixes:
- When exception situation of TCP Connection - Class C private IP
When the module IP and Remote IP is 192.168.xx.xx and third ip is different for each, ARP request operation is not transmitted.(This part had deleted)
- When exception situation of TCP Connection - Class C private IP
1.3.0 Stable
Attached binaries
-
WIZ750SR-TTL / RS232 / RS485
- WIZ750SRv130.bin (App only)
- WIZ750SRv130_incl_Boot.bin (Boot+App)
-
WIZ750SR-100 / 105
- WIZ750SR-10xv130.bin (App only)
- WIZ750SR-10xv130_incl_Boot.bin (Boot+App)
-
WIZ750SR-110
- WIZ750SR-110v130.bin (App only)
- WIZ750SR-110v130_incl_Boot.bin (Boot+App)
* WIZnet S2E config-tool supports firmware update function of application area only. (App only) If you want to program the 'Boot+App' firmware on your device, please use the W7500(P) ISP tool.
- Bug fixes:
- When APP firmware is uploading using the configuration Tool and Board is power off, the product not operate.
- DHCP Lease Time : when DHCP_DEBUG enable, DHCP Lease Time is fixed as 10 second.
- DHCP lease time is modified to use it that information of received packet from DHCP Server.
- The Status LED(PA_07) of WIZ750SR_1xx doesn't operate.
- The Status LED(PA_07) of WIZ750SR_1xx is modified. Turning on an LED and making it blink once per second.
- Compare DHCP Server IP : When DHCP OFFER Packet receive from DHCP Server,the DHCP server ip in packet compare with previous DHCP Server IP.
- Improvements:
- The ISR address have changed to fixed address. The ISR address of APP did no more have to need copy and use in Boot.
1.2.6 Stable
Attached binaries
-
WIZ750SR-TTL / RS232 / RS485
- WIZ750SRv126.bin (App only)
- WIZ750SRv126_incl_Boot.bin (Boot+App)
-
WIZ750SR-100 / 105
- WIZ750SR-10xv126.bin (App only)
- WIZ750SR-10xv126_incl_Boot.bin (Boot+App)
-
WIZ750SR-110
- WIZ750SR-110v126.bin (App only)
- WIZ750SR-110v126_incl_Boot.bin (Boot+App)
* WIZnet S2E config-tool supports firmware update function of application area only. (App only) If you want to program the 'Boot+App' firmware on your device, please use the W7500(P) ISP tool.
-
Bug fixes:
- If serial data packing 'time' option is less than 500ms, the first serial data(+++) ignored in GW mode.
- When UART Tx/RX cross connect and Received UART data size more than 3, UART data don't send .
-
Improvements:
- While IP address is allocating using DHCP ,
- the device can be made searchable using the Configuration tool and it can change the mode(AT mode <-> GW mode).
- It can change the AT mode. It can show that the status of channel change from ATmode to OPEN in Configuration tool. So AT command didn't operate and this bug fixed
- the device can be made searchable using the Configuration tool and it can change the mode(AT mode <-> GW mode).
- While IP address is allocating using DHCP ,
1.2.5 Stable
Attached binaries
-
WIZ750SR-TTL / RS232 / RS485
- WIZ750SRv125.bin (App only)
- WIZ750SRv125_incl_Boot.bin (Boot+App)
-
WIZ750SR-100 / 105
- WIZ750SR-10xv125.bin (App only)
- WIZ750SR-10xv125_incl_Boot.bin (Boot+App)
-
WIZ750SR-110
- WIZ750SR-110v125.bin (App only)
- WIZ750SR-110v125_incl_Boot.bin (Boot+App)
* WIZnet S2E config-tool supports firmware update function of application area only. (App only) If you want to program the 'Boot+App' firmware on your device, please use the W7500(P) ISP tool.
Bug fixes:
- Modyfied the setSn_DHAR() Address offset.
- Modyfied the WIZ750SR-110 HW_Trigger pin.
Improvements:
- If remote ip address is multicast address, enable multicating and set Sn_DHAR, Sn_DIPR, Sn_DPORTR before open socket
v1.2.4 Stable
Attached binaries
-
WIZ750SR-TTL / RS232 / RS485
- WIZ750SRv124.bin (App only)
- WIZ750SRv124_incl_Boot.bin (Boot+App)
-
WIZ750SR-100 / 105 / 110
- WIZ750SR-1xxv124.bin (App only)
- WIZ750SR-1xxv124_incl_Boot.bin (Boot+App)
* WIZnet S2E config-tool supports firmware update function of application area only. (App only) If you want to program the 'Boot+App' firmware on your device, please use the W7500(P) ISP tool.
Bug fixes:
- Serial data packing 'time' option does not work if serial command mode switching code is disabled.
- Fix typo of debug message
Improvements:
- Added the PHY init stabilization code
- Restore TCP connection status function to Status Pin (WIZ750SR-100/105/110 only)
- The Status pin now acts as an 'HW_Trigger' pin(Input at booting) and a TCP connection status pin(output).