Skip to content

Nesvilab/diaTracer

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

13 Commits
 
 
 
 
 
 
 
 

Repository files navigation

diaTracer

Overview

diaTracer is a computational tool that enables spectrum-centric analysis of Bruker's diaPASEF data-independent acquisition proteomics data, facilitating direct (“spectral-library free”) peptide identification and quantification. diaTracer processes diaPASEF raw mass spectrometry data (.d files) and performs three-dimensional (m/z, retention time, ion mobility) peak tracing and feature detection, groups precursor and fragment signals, and generates “pseudo-MS/MS” spectra (in mzML format). These pseudo-MS/MS spectra can then be processed as DDA spectra using MSFragger or any other search engine. diaTracer supports analysis of any diaPASEF proteomics data, including data requiring semi-tryptic (e.g. N-terminomics) or nonspecific (e.g. HLA immunopeptidomics) searches, searches allowing for chemical (e.g. chemical proteomics) or biological modifications (e.g. phosphoproteomics). diaTracer is fast, making direct DIA analysis of large sample cohorts possible. Furthermore, diaTracer enables unrestricted identification of post-translational modifications from diaPASEF data using open/mass offset searches.

diaTracer is available as a stand-alone tool and is fully integrated into FragPipe computational platform.

image Overview of diaTracer and its place within the FragPipe computational platform. diaTracer applies a 3D feature detection algorithm to detect signals from all possible precursors and fragments in MS1 and MS2 diaPASEF data. Pseudo-MS/MS spectra are generated through precursor-fragment clustering and can be processed as DDA data using MSFragger and FragPipe to build a spectral library directly from the data. A hybrid spectral library can also be generated if DDA data are available. This spectral library is then used to extract quantification using DIA-NN.

System requirements

  1. Java 11+
  2. 'ext' folder from the latest MSFragger.
  3. The latest FragPipe (optional).

Download

The latest diaTracer can be downloaded here.

Release note

The up-to-date release note can be found in CHANGELOG.md.

How to run diaTracer

In FragPipe

  1. Download FragPipe from here.
  2. Follow the tutorial.

Standalone usage in command line interface

Run java -jar diaTracer-1.1.4.jar to get options.

java -jar diaTracer-1.1.4.jar --dFilePath <.d file path> --threadNum <thread number>

options:
 -d,--dFilePath <arg>           .d file path
 -dI,--deltaApexIM <arg>        Ion mobility delta range for ms1 and ms2
                                match. default 0.01
 -dR,--deltaApexRT <arg>        Apex scan delta range for ms1 and ms2
                                match. default 3
 -h,--help                      Help
 -help                          Help
 -mC,--ms1MS2Corr <arg>         MS1 and MS2 correlation threshold.
                                default: 0.3
 -mF,--massDefectFilter <arg>   Apply mass defect filter. 1: apply; 0: not
                                apply. default: 1
 -mO,--massDefectOffset <arg>   Mass defect offset. default: 0.1
 -r,--writeInter <arg>          write inter files . 1: write; 0: not
                                write. default: 0
 -rM,--RFMax <arg>              Top N peaks in the spectrum. default: 500
 -t,--threadNum <arg>           thread number
 -w,--workDir <arg>             work directory

Test data

Here is one .d file from the Florian Meier et al.. Please download and unzip it.

java -jar diaTracer-1.1.4.jar --dFilePath ./20200505_Evosep_100SPD_SG06-16_MLHeLa_100ng_py8_S2-C1_1_2731.d --workDir ./ --writeInter 0 --deltaApexIM 0.01 --deltaApexRT 3 --ms1MS2Corr 0.3 --massDefectFilter 0 --massDefectOffset 0.1 --RFMax 500 --threadNum 12

After runing the above command, a mzML file named 20200505_Evosep_100SPD_SG06-16_MLHeLa_100ng_py8_S2-C1_1_2731_diaTracer.mzML will be generated in the same path of .d file. The running time will be around 10 minutes using 12 threads.

Publication

diaTracer enables spectrum-centric analysis of diaPASEF proteomics data
Kai Li, Guo Ci Teo, Kevin L. Yang, Fengchao Yu, Alexey I. Nesvizhskii
bioRxiv, DOI: 10.1101/2024.05.25.595875

Releases

No releases published

Packages

No packages published

Contributors 4

  •  
  •  
  •  
  •