Twin Robotic Computed Tomography Geometries / ASTRA #515
Conversation
Hi Simon, Thanks, this is fantastic work, and indeed super useful. #383 mentions this, because indeed, if you have a standard CBCT, TIGRE geometry is more intuitive, but with arbitrary motions TIGRE becomes quite complex to define, and ASTRA is quite good for that. I am correct then assuming that your function Also: what do you mean to make a more arbitrary interface? you mean changing the TIGRE geo in general to be more vector like, as ASTRA does? |
Hi, I just had a quick look at the cuda files, but it seems that in the projector the 3D position of the source and detector is needed? So I thought it might be worth looking into whether an interface can be made for this geometry / data? I am new to the framework so I do not have a good overview :D |
This is wonderful!
What do you mean here?
That parameter you are linking there is the location of the origin of the detector in "projection geometry". Basically encoding the detector offset. Its the world coordinates in "projection geometry" for pixel (0,0) in the detector. Note that the "projection geometry" is this slightly strange geometry where the first voxel of the volume is always at (0,0,0) and the voxel sizes are always (1,1,1). The entire rest of the world is rotated and scaled accordingly. It makes the main loop at L193 much more efficient.
To have an interface in this "projection geometry" may be possible, but no sure if desirable, as its a bit complex and not human readable easily. However, this geometry is computed from the TIGRE geometry at: |
We do not know exactly the origin of our CT trajectory because we use a pose estimation algorithm and get the projection geometries relative to a phantom. So I implemented this function: If the origin is known, the source and detector positions should be transformed before using the function. Then the volumes should be reconstructed on the same volume grid.
OK! |
Would it make perhaps more sense to have as an input This would keep a functionality (correcting for trajectory center) locate in a single place, making it hopefully more intuitive to use. What do you think? |
Thanks! Are you OK with me merging this? |
Yes! Thanks for the quick replies! I have also updated the colab example. |
Fantastic :) And thanks again for contributing, TIGRE keeps alive thanks of people like you :) |
Hello TIGRE team!
I am a PhD student at the Deggendorf Institute of Technology where we are working with a twin robotic computed tomography scanner. I usually use the astra toolbox for reconstruction, but I wanted to try out the many algorithms implemented in the TIGRE toolbox and the cool features like the multi GPU! I found it rather unintuitive to convert the complex arbitrary geometry into TIGRE, so I've added a utility function. I tested the results and made a short colab example with the conversion from astra to TIGRE (I thought it might be interesting for others).
https://colab.research.google.com/drive/1c6tEySsv63zIdkHvo6agg3O2vJoKYTC1?usp=sharing
With our twin robot CT system we have correction values for each projection. I found the TIGRE interface rather unintuitive, especially compared to the Astra 'cone_vec' interface. I took a quick look at the TIGRE cuda files and found that in the forward and backprojector the interface is more or less the same as the Astra 'cone_vec' geometry. Is it worth looking into this and maybe making a more "arbitrary" python interface for TIGRE? I might look into it when I have some spare time.
Greetings Simon