25 changes: 11 additions & 14 deletions offline/cable_cru_TRENDY.F90
Original file line number Diff line number Diff line change
Expand Up @@ -537,16 +537,6 @@ SUBROUTINE get_daily_met(CRU)
land_x, land_y, MetYear, MetDay, CRU%LeapYears, CRU%xDimSize,&
CRU%yDimSize, CRU%DirectRead)

!MetYear = CRU%cYear
!! If the variable is time recycled
!IF (CRU%isRecycled(VarIndx)) THEN
!MetYear = RecycledYear
!END IF

!! CRU%CTStep is the current day, which we use to index the netCDF arrays
!CALL read_metvals(CRU%MetDatasets(VarIndx), CRU%Met(VarIndx)%MetVals,&
!land_x, land_y, MetYear, CRU%CTStep, CRU%LeapYears, CRU%xDimSize,&
!CRU%yDimSize, CRU%DirectRead)
END DO IterateVariables

! Previous day variables
Expand Down Expand Up @@ -576,7 +566,7 @@ SUBROUTINE get_daily_met(CRU)
CRU%yDimSize, CRU%DirectRead)

! vph0900
CALL get_met_date(CRU%cYear, CRU%CTStep-1, CRU%IsRecycled(vph0900),&
CALL get_met_date(CRU%cYear, CRU%CTStep+1, CRU%IsRecycled(vph0900),&
CRU%RecycStartYear, CRU%MetRecycPeriod, CRU%LeapYears, MetYear,&
MetDay)
CALL read_metvals(CRU%MetDatasets(vph0900), CRU%Met(nextvph0900)%MetVals,&
Expand Down Expand Up @@ -742,7 +732,7 @@ SUBROUTINE get_met_date(SimYear, SimDay, IsRecycled, RecycleStart,&
! meteorology from 01/01/1951, and consequently some of the previos day's
! meteorology. The "previous day" with respect to the meteorology can be
! either 31/12/1950 or 31/12/1960, depending on when the MODULO is applied.
! The current approach would use 31/12/1949 as the previous day, which is less
! The current approach would use 31/12/1950 as the previous day, which is less
! likely to cause issues with large jumps in the time-local conditions.
! Also simplifies leap year handling. In that instance, we can simply check
! whether the new year is a leap year or not, instead of passing the new year
Expand All @@ -764,7 +754,14 @@ SUBROUTINE get_met_date(SimYear, SimDay, IsRecycled, RecycleStart,&
END IF

! Check the validity of the passed day
IF (SimDay <= 0) THEN
IF ((SimDay < -364) .OR. (SimDay > (DaysInYear + 365)) THEN
! Looking more than a year into the past/future- this routine was never
! meant for such tasks.
WRITE(ERROR_UNIT,*) "Looking too far into the past/future. "//&
"The get_met_date routine was only intended for nearby temporal "//&
"searching, not more than a year in the future/past."
EXIT 5
IF (SimDay < 1) THEN
! Go back to last year- set the day later, once we know whether the MetYear
! is a leapyear or not
MetYear = SimYear - 1
Expand All @@ -774,7 +771,7 @@ SUBROUTINE get_met_date(SimYear, SimDay, IsRecycled, RecycleStart,&
IF ((LeapYears) .AND. is_leapyear(MetYear)) THEN
MetDay = 366 + SimDay
END IF
ELSEIF (SimDay == (DaysInYear + 1)) THEN
ELSEIF (SimDay > DaysInYear) THEN
MetYear = SimYear + 1
MetDay = SimDay - DaysInYear
ELSE
Expand Down