When used for cooling, Relay 2 will turn on based on temperature change, but will not switch back off although the snowflake reverts back to a thermometer. I can manually control the relay under devices and control and turn it off.
Does not appear to be an issue if I set cooler_relay: "1", in the ESP Home yaml.
target_low: appears to be a required override in the ESP yaml, otherwise compiling fails when calling "nspanel_esphome_addon_climate_dual.yamll", however not an issue using "nspanel_esphome_addon_climate_cool.yaml"
In the climate card when I increase or decrease the temperature using the "+" or "-", the set point appears to step in increments of (0.9) so there may be a round down error opposed to a round up to the nearest integer, so I tend to get some odd temperature set points in roundoff of multiples of 0.9.
Internal temperature sensors does not get converted from C to F, automatically when displaying to the panel.
climate.nspx_thermostat entity reads correctly in HA Developer tools as 73.2 F, but when I use that variable on the nspanel, home display it reads out as 22.8 F. I have, of course have "temp_units: "°F" , defined in my yaml.
The temperature, does oddly display correctly on the climate page. ** An indoor temperature sensor is not necessary. Leave the field empty if you want to use the temperature sensor of the NSPanel.
Steps to Reproduce
Use Case: use nspanel for local control of water heating/cooling system.
NSPannel running 4.3.4, with default blueprint.
ESP Home yaml below for reference.
Your Panel's YAML
substitutions:
# Settings - Editable valuesdevice_name: "nsp3"wifi_ssid:
wifi_password:
# Add-on configuration (if needed)## Add-on climateheater_relay: "1"# Possible values: "1" or "2"cooler_relay: "1"# Possible values: "1" or "2"temp_units: "°F"# Temperatures in Fahrenheitmin_off_time: "3"# Minimum duration (in seconds) the cooling/heating action must be disengaged before it may be engaged.min_run_time: "3"# Minimum duration (in seconds) the cooling/heating action must be engaged before it may be disengaged.min_idle_time: "3"# Minimum duration (in seconds) the idle action must be active before calling another climate action.temp_min: "65"# Min supported temperature is 40°Ftemp_max: "80"# Max supported temperature is 80°Ftemp_step: "1"# Temperature granularity is 1°Fcool_deadband: "1.2"# Temperature delta before engaging coolingcool_overrun: "1.2"# Temperature delta before disengaging coolingheat_deadband: "1.2"# Temperature delta before engaging heatheat_overrun: "1.2"# Temperature delta before disengaging heattarget_low: "74"# The initial lower treshold for the target temperature.target_high: "74"# The initial higher threshold for the target temperature.# Basic and optional configurationspackages:
remote_package:
url: https://github.com/Blackymas/NSPanel_HA_Blueprintref: mainfiles:
- nspanel_esphome.yaml # Basic package# Optional advanced and add-on configurations# - esphome/nspanel_esphome_advanced.yaml
- nspanel_esphome_addon_climate_cool.yaml# - nspanel_esphome_addon_climate_heat.yaml# - nspanel_esphome_addon_climate_dual.yamlrefresh: 300s
ESPHome Logs
No response
Home Assistant Logs
No response
The text was updated successfully, but these errors were encountered:
zembrzycki
added
the
Bug
Identifies an issue where the system is not functioning as expected.
label
Apr 17, 2024
zembrzycki
changed the title
Issue with climate Add-on: Climate - multiple issues identified.
Issue with Add-on: Climate - multiple issues identified.
Apr 17, 2024
Thank You Edward!!!
I confirmed, those two issues have been resolved.
I will report issues separately next time now that I see how the dev workflow works.
TFT Version
4.3.4
ESPHome Version
4.3.4
Blueprint Version
4.3.4
Panel Model
US
What is the bug?
When used for cooling, Relay 2 will turn on based on temperature change, but will not switch back off although the snowflake reverts back to a thermometer. I can manually control the relay under devices and control and turn it off.
Does not appear to be an issue if I set cooler_relay: "1", in the ESP Home yaml.
target_low: appears to be a required override in the ESP yaml, otherwise compiling fails when calling "nspanel_esphome_addon_climate_dual.yamll", however not an issue using "nspanel_esphome_addon_climate_cool.yaml"
In the climate card when I increase or decrease the temperature using the "+" or "-", the set point appears to step in increments of (0.9) so there may be a round down error opposed to a round up to the nearest integer, so I tend to get some odd temperature set points in roundoff of multiples of 0.9.
Internal temperature sensors does not get converted from C to F, automatically when displaying to the panel.
climate.nspx_thermostat entity reads correctly in HA Developer tools as 73.2 F, but when I use that variable on the nspanel, home display it reads out as 22.8 F. I have, of course have "temp_units: "°F" , defined in my yaml.
The temperature, does oddly display correctly on the climate page. ** An indoor temperature sensor is not necessary. Leave the field empty if you want to use the temperature sensor of the NSPanel.
Steps to Reproduce
Use Case: use nspanel for local control of water heating/cooling system.
NSPannel running 4.3.4, with default blueprint.
ESP Home yaml below for reference.
Your Panel's YAML
ESPHome Logs
No response
Home Assistant Logs
No response
The text was updated successfully, but these errors were encountered: