GEN3 inverters lost the connection directly after connection establishment #102

Closed
s-allius opened this issue Jun 18, 2024 · 1 comment
Closed
Assignees
Labels
bug Something isn't working

Comments

@s-allius
Copy link
Owner

Maybe I found the problem.
The GEN3 inverter seems to have problems when we send a second MODBUS command directly after we received a MODBUS response. During the tests of the version 0.8.0 I never saw this behaviour. I have prepared a hotfix for that. When the test tomorrow are passes I will release a fix version 0.8.1 soon

Originally posted by @s-allius in #89 (comment)

@s-allius s-allius self-assigned this Jun 18, 2024
@s-allius s-allius added the bug Something isn't working label Jun 18, 2024
This was referenced Jun 18, 2024
@s-allius
Copy link
Owner Author

Fixed with version 0.8.1 #103