You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
For TC-DRLK-3.2, the expected outcome in the verifications sheet doesn't show the right commandID values for steps 14, 16 and 17
Description:
For TC-DRLK-3.2, step 14, the expected commandID is 0x1b. The verification sheet shows 0x1c. Here is the spec screenshot for the same showing 0x1b.
The same for step 16 and step 17. The expected outcome for these steps are 0x22 and 0x24.
Steps to reproduce:
Please execute steps 14, 16 and 17 with chip-tool and compare the commandIDs that are shown in the log with the Spec and the Verification Document expected outcome for that step. Observe that the commandIDs shown by the chip tool logs and Specs match but the same is different from what is shown in the Verification Document expected outcome.
The text was updated successfully, but these errors were encountered:
Summary Title:
For TC-DRLK-3.2, the expected outcome in the verifications sheet doesn't show the right commandID values for steps 14, 16 and 17
Description:
The same for step 16 and step 17. The expected outcome for these steps are 0x22 and 0x24.
Steps to reproduce:
The text was updated successfully, but these errors were encountered: