Hi, i noticed a strange behaviour:
there seems to be some "interconnection" between coil and contacts of a relay ....
can be reproduced with simple circuit attached.
relay issue
relay issue.txt

@rolox2022
Copy link
Author

Edit...its obviously a misunderstanding on my side...the parameter "off resistance" is by default 1M which affects low current signals switched by relay and also is related to contact-contact resistance as kind of "isolation resistance"
As in the example no current is applicable with only testpoints, the full 5V show up at the open contacts ....

@pfalstad
Copy link
Owner

Yes, that's correct. You need a pulldown resistor if you want the open contact to be grounded.