Status: Experimental
Table of Contents
A LoggerProvider
MUST provide a way to allow a Resource
to be specified. If a Resource
is specified, it SHOULD be associated with all
the LogRecords
produced by any Logger
from the LoggerProvider
.
New Logger
instances are always created through a LoggerProvider
(see API). The name
, version
(optional), and attributes
(optional)
supplied to the LoggerProvider
must be used to create
an InstrumentationScope
instance which
is stored on the created Logger
.
Configuration (i.e. LogRecordProcessors) MUST be managed
solely by the LoggerProvider
and the SDK MUST provide some way to configure
all options that are implemented by the SDK. This MAY be done at the time
of LoggerProvider
creation if appropriate.
The LoggerProvider
MAY provide methods to update the configuration. If
configuration is updated (e.g., adding a LogRecordProcessor
), the updated
configuration MUST also apply to all already returned Loggers
(i.e. it MUST
NOT matter whether a Logger
was obtained from the LoggerProvider
before or
after the configuration change). Note: Implementation-wise, this could mean
that Logger
instances have a reference to their LoggerProvider
and access
configuration only via this reference.
This method provides a way for provider to do any cleanup required.
Shutdown
MUST be called only once for each LoggerProvider
instance. After
the call to Shutdown
, subsequent attempts to get a Logger
are not allowed.
SDKs SHOULD return a valid no-op Logger
for these calls, if possible.
Shutdown
SHOULD provide a way to let the caller know whether it succeeded,
failed or timed out.
Shutdown
SHOULD complete or abort within some timeout. Shutdown
MAY be
implemented as a blocking API or an asynchronous API which notifies the caller
via a callback or an event. OpenTelemetry SDK authors MAY
decide if they want to make the shutdown timeout configurable.
Shutdown
MUST be implemented at least by invoking Shutdown
on all
registered LogRecordProcessors.
This method provides a way for provider to notify the
registered LogRecordProcessors to immediately export all
ReadableLogRecords
that have not yet been exported.
ForceFlush
SHOULD provide a way to let the caller know whether it succeeded,
failed or timed out. ForceFlush
SHOULD return some ERROR status if there
is an error condition; and if there is no error condition, it should return
some NO ERROR status, language implementations MAY decide how to model
ERROR and NO ERROR.
ForceFlush
SHOULD complete or abort within some timeout. ForceFlush
MAY be
implemented as a blocking API or an asynchronous API which notifies the caller
via a callback or an event. OpenTelemetry SDK authors MAY
decide if they want to make the flush timeout configurable.
ForceFlush
MUST invoke ForceFlush
on all
registered LogRecordProcessors.
In addition to the API-level definition for LogRecord, the
following LogRecord
-like interfaces are defined in the SDK:
A function receiving this as an argument MUST be able to access all the
information added to the LogRecord. It MUST also be able to
access the Instrumentation Scope
and Resource information (implicitly)
associated with the LogRecord
.
Counts for attributes due to collection limits MUST be available for exporters to report as described in the transformation to non-OTLP formats specification.
Note: Typically this will be implemented with a new interface or (immutable) value type.
A function receiving this as an argument MUST be able to write to the
full LogRecord and additionally MUST be able to retrieve all
information
that was added to the LogRecord
(as with
ReadableLogRecord).
LogRecordProcessor
is an interface which allows hooks for LogRecord
emitting.
Built-in processors are responsible for batching and conversion of LogRecords
to exportable representation and passing batches to exporters.
LogRecordProcessors
can be registered directly on SDK LoggerProvider
and
they are invoked in the same order as they were registered.
Each processor registered on LoggerProvider
is part of a pipeline that
consists of a processor and optional exporter. The SDK
MUST allow each pipeline to end with an individual exporter.
The SDK MUST allow users to implement and configure custom processors and decorate built-in processors for advanced scenarios such as enriching with attributes or filtering.
The following diagram shows LogRecordProcessor
's relationship to other
components in the SDK:
+-----+------------------------+ +------------------------------+ +-------------------------+
| | | | | | |
| | | | Batching LogRecordProcessor | | LogRecordExporter |
| | +---> Simple LogRecordProcessor +---> (OtlpExporter) |
| | | | | | |
| SDK | Logger.emit(LogRecord) | +------------------------------+ +-------------------------+
| | |
| | |
| | |
| | |
| | |
+-----+------------------------+
OnEmit
is called when a LogRecord
is emitted. This
method is called synchronously on the thread that emitted the LogRecord
,
therefore it SHOULD NOT block or throw exceptions.
Parameters:
logRecord
- a ReadWriteLogRecord for the emittedLogRecord
.context
- theContext
that the SDK determined (the explicitly passedContext
, the currentContext
, or an emptyContext
if the Logger was obtained withinclude_trace_context=false
)
Returns: Void
A LogRecordProcessor
may freely modify logRecord
for the duration of
the OnEmit
call. If logRecord
is needed after OnEmit
returns (i.e. for
asynchronous processing) only reads are permitted.
Shuts down the processor. Called when the SDK is shut down. This is an opportunity for the processor to do any cleanup required.
Shutdown
SHOULD be called only once for each LogRecordProcessor
instance.
After the call to Shutdown
, subsequent calls to OnEmit
are not allowed. SDKs
SHOULD ignore these calls gracefully, if possible.
Shutdown
SHOULD provide a way to let the caller know whether it succeeded,
failed or timed out.
Shutdown
MUST include the effects of ForceFlush
.
Shutdown
SHOULD complete or abort within some timeout. Shutdown
can be
implemented as a blocking API or an asynchronous API which notifies the caller
via a callback or an event. OpenTelemetry SDK authors can decide if they want
to make the shutdown timeout configurable.
This is a hint to ensure that any tasks associated with LogRecords
for which
the LogRecordProcessor
had already received events prior to the call
to ForceFlush
SHOULD be completed as soon as possible, preferably before
returning from this method.
In particular, if any LogRecordProcessor
has any associated exporter, it
SHOULD try to call the exporter's Export
with all LogRecords
for which this
was not already done and then invoke ForceFlush
on it.
The built-in LogRecordProcessors MUST do so. If a
timeout is specified (see below), the LogRecordProcessor
MUST prioritize
honoring the timeout over
finishing all calls. It MAY skip or abort some or all Export or ForceFlush calls
it has made to achieve this goal.
ForceFlush
SHOULD provide a way to let the caller know whether it succeeded,
failed or timed out.
ForceFlush
SHOULD only be called in cases where it is absolutely necessary,
such as when using some FaaS providers that may suspend the process after an
invocation, but before the LogRecordProcessor
exports the
completed LogRecords
.
ForceFlush
SHOULD complete or abort within some timeout. ForceFlush
can be
implemented as a blocking API or an asynchronous API which notifies the caller
via a callback or an event. OpenTelemetry SDK authors can decide if they want to
make the flush timeout configurable.
The standard OpenTelemetry SDK MUST implement both simple and batch processors, as described below. Other common processing scenarios should be first considered for implementation out-of-process in OpenTelemetry Collector.
This is an implementation of LogRecordProcessor
which passes finished logs and
passes the export-friendly ReadableLogRecord
representation to the
configured LogRecordExporter, as soon as they are
finished.
Configurable parameters:
exporter
- the exporter where theLogRecords
are pushed.
This is an implementation of the LogRecordProcessor
which create batches
of LogRecords
and passes the export-friendly ReadableLogRecord
representations to the configured LogRecordExporter
.
Configurable parameters:
exporter
- the exporter where theLogRecords
are pushed.maxQueueSize
- the maximum queue size. After the size is reached logs are dropped. The default value is TODO.scheduledDelayMillis
- the delay interval in milliseconds between two consecutive exports. The default value is TODO.exportTimeoutMillis
- how long the export can run before it is cancelled. The default value is TODO.maxExportBatchSize
- the maximum batch size of every export. It must be smaller or equal tomaxQueueSize
. The default value is TODO.
LogRecordExporter
defines the interface that protocol-specific exporters must
implement so that they can be plugged into OpenTelemetry SDK and support sending
of telemetry data.
The goal of the interface is to minimize burden of implementation for protocol-dependent telemetry exporters. The protocol exporter is expected to be primarily a simple telemetry data encoder and transmitter.
A LogRecordExporter
MUST support the following functions:
Exports a batch of ReadableLogRecords. Protocol exporters that will implement this function are typically expected to serialize and transmit the data to the destination.
Export
will never be called concurrently for the same exporter instance.
Depending on the implementation the result of the export may be returned to the
Processor not in the return value of the call to Export
but in a language
specific way for signaling completion of an asynchronous task. This means that
while an instance of an exporter will never have it Export
called concurrently
it does not mean that the task of exporting can not be done concurrently. How
this is done is outside the scope of this specification. Each implementation
MUST document the concurrency characteristics the SDK requires of the exporter.
Export
MUST NOT block indefinitely, there MUST be a reasonable upper limit
after which the call must time out with an error result (Failure
).
Concurrent requests and retry logic is the responsibility of the exporter. The
default SDK's LogRecordProcessors
SHOULD NOT implement retry logic, as the
required logic is likely to depend heavily on the specific protocol and backend
the logs are being sent to. For example,
the OpenTelemetry Protocol (OTLP) specification defines
logic for both sending concurrent requests and retrying requests.
Parameters:
batch
- a batch of ReadableLogRecords. The exact data type of the batch is language specific, typically it is some kind of list, e.g. for logs in Java it will be typicallyCollection<LogRecordData>
.
Returns: ExportResult
The return of Export
is implementation specific. In what is idiomatic for the
language the Exporter must send an ExportResult
to the
Processor. ExportResult
has values of either Success
or Failure
:
Success
- The batch has been successfully exported. For protocol exporters this typically means that the data is sent over the wire and delivered to the destination server.Failure
- exporting failed. The batch must be dropped. For example, this can happen when the batch contains bad data and cannot be serialized.
For example, in Java the return of Export
would be a Future which when
completed returns the ExportResult
object. While in Erlang the exporter sends
a message to the processor with the ExportResult
for a particular batch.
This is a hint to ensure that the export of any ReadableLogRecords
the
exporter has received prior to the call to ForceFlush
SHOULD be completed as
soon as possible, preferably before returning from this method.
ForceFlush
SHOULD provide a way to let the caller know whether it succeeded,
failed or timed out.
ForceFlush
SHOULD only be called in cases where it is absolutely necessary,
such as when using some FaaS providers that may suspend the process after an
invocation, but before the exporter exports the ReadlableLogRecords
.
ForceFlush
SHOULD complete or abort within some timeout. ForceFlush
can be
implemented as a blocking API or an asynchronous API which notifies the caller
via a callback or an event. OpenTelemetry SDK authors MAY
decide if they want to make the flush timeout configurable.
Shuts down the exporter. Called when SDK is shut down. This is an opportunity for exporter to do any cleanup required.
Shutdown SHOULD be called only once for each LogRecordExporter
instance. After
the call to Shutdown
subsequent calls to Export
are not allowed and should
return a Failure result.
Shutdown
SHOULD NOT block indefinitely (e.g. if it attempts to flush the data
and the destination is unavailable). OpenTelemetry SDK
authors MAY decide if they want to make the shutdown timeout configurable.