-
Notifications
You must be signed in to change notification settings - Fork 1
/
ADS1256_definitions.py
102 lines (94 loc) · 2.95 KB
/
ADS1256_definitions.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
################### CONSTANT DEFINITIONS for class ADS1256 ####################
# Register addresses:
REG_STATUS = 0x00
REG_MUX = 0x01
REG_ADCON = 0x02
REG_DRATE = 0x03
REG_IO = 0x04
REG_OFC0 = 0x05
REG_OFC1 = 0x06
REG_OFC2 = 0x07
REG_FSC0 = 0x08
REG_FSC1 = 0x09
REG_FSC2 = 0x0A
NUM_REG = 11
# REG_STATUS: Flags:
BUFFER_ENABLE = 0x02
AUTOCAL_ENABLE = 0x04
ORDER_LSB = 0x08
# REG_MUX: High nibble selects positive input, low nibble negative input.
# Pin selection codes: logic OR together to form the register value.
# Example: ads1256.mux = POS_AIN0 | NEG_AINCOM
# Pin selection codes for the positive input:
POS_AIN0 = 0x00
POS_AIN1 = 0x10
POS_AIN2 = 0x20
POS_AIN3 = 0x30
POS_AIN4 = 0x40
POS_AIN5 = 0x50
POS_AIN6 = 0x60
POS_AIN7 = 0x70
POS_AINCOM = 0x80
# Pin selection codes for the negative input:
NEG_AIN0 = 0x00
NEG_AIN1 = 0x01
NEG_AIN2 = 0x02
NEG_AIN3 = 0x03
NEG_AIN4 = 0x04
NEG_AIN5 = 0x05
NEG_AIN6 = 0x06
NEG_AIN7 = 0x07
NEG_AINCOM = 0x08
# REG_ADCON: Gain levels
# Note: You can set the numeric values 1, 2, 4, 8, 16, 32 and 64 directly
# via class/instance property ADS1256.pga_gain.
GAIN_1 = 0x00
GAIN_2 = 0x01
GAIN_4 = 0x02
GAIN_8 = 0x03
GAIN_16 = 0x04
GAIN_32 = 0x05
GAIN_64 = 0x06
# REG_ADCON: Sensor Detect Current Sources
SDCS_OFF = 0x00
SDCS_500pA = 0x08
SDCS_2uA = 0x10
SDCS_10uA = 0x18
# REG_ADCON: Clock output pin settings
CLKOUT_OFF = 0x00
CLKOUT_EQUAL = 0x20
CLKOUT_HALF = 0x40
CLKOUT_FOURTH = 0x60
# REG_DRATE: Sample rate definitions:
DRATE_30000 = 0b11110000 # 30,000SPS (default)
DRATE_15000 = 0b11100000 # 15,000SPS
DRATE_7500 = 0b11010000 # 7,500SPS
DRATE_3750 = 0b11000000 # 3,750SPS
DRATE_2000 = 0b10110000 # 2,000SPS
DRATE_1000 = 0b10100001 # 1,000SPS
DRATE_500 = 0b10010010 # 500SPS
DRATE_100 = 0b10000010 # 100SPS
DRATE_60 = 0b01110010 # 60SPS
DRATE_50 = 0b01100011 # 50SPS
DRATE_30 = 0b01010011 # 30SPS
DRATE_25 = 0b01000011 # 25SPS
DRATE_15 = 0b00110011 # 15SPS
DRATE_10 = 0b00100011 # 10SPS
DRATE_5 = 0b00010011 # 5SPS
DRATE_2_5 = 0b00000011 # 2.5SPS
# Chip-level-command Definitions. Special functions implemented in this
# class take care of command order / timeouts and handling of data/results.
CMD_WAKEUP = 0x00 # Completes SYNC and exits standby mode
CMD_RDATA = 0x01 # Read data
CMD_RDATAC = 0x03 # Start read data continuously
CMD_SDATAC = 0x0F # Stop read data continuously
CMD_RREG = 0x10 # Read from register
CMD_WREG = 0x50 # Write to register
CMD_SELFCAL = 0xF0 # Offset and gain self-calibration
CMD_SELFOCAL= 0xF1 # Offset self-calibration
CMD_SELFGCAL= 0xF2 # Gain self-calibration
CMD_SYSOCAL = 0xF3 # System offset calibration
CMD_SYSGCAL = 0xF4 # System gain calibration
CMD_SYNC = 0xFC # Synchronize the A/D conversion
CMD_STANDBY = 0xFD # Begin standby mode
CMD_RESET = 0xFE # Reset to power-on values