forked from Azure/iotedge
-
Notifications
You must be signed in to change notification settings - Fork 0
/
CodeCoverage.runsettings
155 lines (146 loc) · 7.91 KB
/
CodeCoverage.runsettings
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
<?xml version="1.0" encoding="utf-8"?>
<!-- File name extension must be .runsettings -->
<RunSettings>
<DataCollectionRunSettings>
<DataCollectors>
<DataCollector friendlyName="Code Coverage" uri="datacollector://Microsoft/CodeCoverage/2.0" assemblyQualifiedName="Microsoft.VisualStudio.Coverage.DynamicCoverageDataCollector, Microsoft.VisualStudio.TraceCollector, Version=11.0.0.0, Culture=neutral, PublicKeyToken=b03f5f7f11d50a3a">
<Configuration>
<CodeCoverage>
<!--
Additional paths to search for .pdb (symbol) files. Symbols must be found for modules to be instrumented.
If .pdb files are in the same folder as the .dll or .exe files, they are automatically found. Otherwise, specify them here.
Note that searching for symbols increases code coverage runtime. So keep this small and local.
-->
<!--
<SymbolSearchPaths>
<Path>C:\Users\User\Documents\Visual Studio 2012\Projects\ProjectX\bin\Debug</Path>
<Path>\\mybuildshare\builds\ProjectX</Path>
</SymbolSearchPaths>
-->
<!--
About include/exclude lists:
Empty "Include" clauses imply all; empty "Exclude" clauses imply none.
Each element in the list is a regular expression (ECMAScript syntax). See http://msdn.microsoft.com/library/2k3te2cs.aspx.
An item must first match at least one entry in the include list to be included.
Included items must then not match any entries in the exclude list to remain included.
-->
<!-- Match assembly file paths: -->
<ModulePaths>
<Include>
<ModulePath>.*\.dll$</ModulePath>
<ModulePath>.*\.exe$</ModulePath>
</Include>
<Exclude>
<!-- test/prod dependencies -->
<ModulePath>.*windowsazure\..*</ModulePath>
<ModulePath>.*moq\..*</ModulePath>
<ModulePath>.*app.metrics.*\..*</ModulePath>
<ModulePath>.*autofac.*</ModulePath>
<ModulePath>.*bouncycastle\..*</ModulePath>
<ModulePath>.*fluentassertions.*</ModulePath>
<ModulePath>.*microsoft.codeanalysis\..*</ModulePath>
<ModulePath>.*microsoft.identitymodel\..*</ModulePath>
<ModulePath>.*newtonsoft\..*</ModulePath>
<ModulePath>.*nito\..*</ModulePath>
<ModulePath>.*nunit.framework\..*</ModulePath>
<ModulePath>.*nunit3.testadapter\..*</ModulePath>
<ModulePath>.*prometheus-net.*</ModulePath>
<ModulePath>.*protobuf-net.*</ModulePath>
<ModulePath>.*stackexchange\..*</ModulePath>
<ModulePath>.*system.identitymodel\..*</ModulePath>
<ModulePath>.*system.reactive.*</ModulePath>
<ModulePath>.*system.linq.async.*</ModulePath>
<ModulePath>.*xunit\..*</ModulePath>
<ModulePath>.*edgex509authdownstreamdevice.*\..*</ModulePath>
<ModulePath>.*edgedownstreamdevice.*\..*</ModulePath>
<!-- test binaries -->
<ModulePath>.*test\..*</ModulePath>
<!-- test/sample edge modules -->
<ModulePath>.*cloudtodevicemessagetester\..*</ModulePath>
<ModulePath>.*deploymenttester\..*</ModulePath>
<ModulePath>.*directmethodreceiver\..*</ModulePath>
<ModulePath>.*directmethodsender\..*</ModulePath>
<ModulePath>.*edgehubrestarttester\..*</ModulePath>
<ModulePath>.*iotedgequickstart\..*</ModulePath>
<ModulePath>.*leafdevice\..*</ModulePath>
<ModulePath>.*load-gen\..*</ModulePath>
<ModulePath>.*manifestsignerclient.*\..*</ModulePath>
<ModulePath>.*metricscollector\..*</ModulePath>
<ModulePath>.*metricsvalidator\..*</ModulePath>
<ModulePath>.*numberlogger\..*</ModulePath>
<ModulePath>.*modulerestarter\..*</ModulePath>
<ModulePath>.*networkcontroller\..*</ModulePath>
<ModulePath>.*relayer\..*</ModulePath>
<ModulePath>.*simulatedtemperaturesensor\..*</ModulePath>
<ModulePath>.*temperaturefilter\..*</ModulePath>
<ModulePath>.*testanalyzer\..*</ModulePath>
<ModulePath>.*testresultcoordinator\..*</ModulePath>
<ModulePath>.*twintester\..*</ModulePath>
<ModulePath>.*microsoft.azure.webjobs.*</ModulePath>
</Exclude>
</ModulePaths>
<!-- Match fully qualified names of functions: -->
<!-- (Use "\." to delimit namespaces in C# or Visual Basic, "::" in C++.) -->
<Functions>
<Exclude>
<Function>^Fabrikam\.UnitTest\..*</Function>
<Function>^std::.*</Function>
<Function>^ATL::.*</Function>
<Function>.*::__GetTestMethodInfo.*</Function>
<Function>^Microsoft::VisualStudio::CppCodeCoverageFramework::.*</Function>
<Function>^Microsoft::VisualStudio::CppUnitTestFramework::.*</Function>
</Exclude>
</Functions>
<!-- Match attributes on any code element: -->
<Attributes>
<Exclude>
<!-- Don't forget "Attribute" at the end of the name -->
<Attribute>^System\.Diagnostics\.DebuggerHiddenAttribute$</Attribute>
<Attribute>^System\.Diagnostics\.DebuggerNonUserCodeAttribute$</Attribute>
<Attribute>^System\.Runtime\.CompilerServices.CompilerGeneratedAttribute$</Attribute>
<Attribute>^System\.CodeDom\.Compiler.GeneratedCodeAttribute$</Attribute>
<Attribute>^System\.Diagnostics\.CodeAnalysis.ExcludeFromCodeCoverageAttribute$</Attribute>
</Exclude>
</Attributes>
<!-- Match the path of the source files in which each method is defined: -->
<Sources>
<Exclude>
<Source>.*\\atlmfc\\.*</Source>
<Source>.*\\vctools\\.*</Source>
<Source>.*\\public\\sdk\\.*</Source>
<Source>.*\\microsoft sdks\\.*</Source>
<Source>.*\\vc\\include\\.*</Source>
<Source>.*\\edge-util\\src\\es6numberserializer\\.*</Source>
<Source>.*\\edge-util\\src\\jsoncanonicalizer\\.*</Source>
</Exclude>
</Sources>
<!-- Match the company name property in the assembly: -->
<CompanyNames>
<Exclude>
<CompanyName>.*microsoft.*</CompanyName>
</Exclude>
</CompanyNames>
<!-- Match the public key token of a signed assembly: -->
<PublicKeyTokens>
<!-- Exclude Visual Studio extensions: -->
<Exclude>
<PublicKeyToken>^B77A5C561934E089$</PublicKeyToken>
<PublicKeyToken>^B03F5F7F11D50A3A$</PublicKeyToken>
<PublicKeyToken>^31BF3856AD364E35$</PublicKeyToken>
<PublicKeyToken>^89845DCD8080CC91$</PublicKeyToken>
<PublicKeyToken>^71E9BCE111E9429C$</PublicKeyToken>
<PublicKeyToken>^8F50407C4E9E73B6$</PublicKeyToken>
<PublicKeyToken>^E361AF139669C375$</PublicKeyToken>
</Exclude>
</PublicKeyTokens>
<!-- We recommend you do not change the following values: -->
<UseVerifiableInstrumentation>True</UseVerifiableInstrumentation>
<AllowLowIntegrityProcesses>True</AllowLowIntegrityProcesses>
<CollectFromChildProcesses>True</CollectFromChildProcesses>
<CollectAspDotNet>False</CollectAspDotNet>
</CodeCoverage>
</Configuration>
</DataCollector>
</DataCollectors>
</DataCollectionRunSettings>
</RunSettings>