@mirza-s Please, check out 1.8. Seems, like the issue is not reproducible on this version |
Issue not present in v1.8. Thank you. |
While the vertical issue is resolved. It appears that the horizontal time axis is all over the place. |
duplicate of jaegertracing/jaeger-ui#270 |
should be fixed by jaegertracing/jaeger-ui#274 |
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Units in scatter plot are not consistent with displayed data.
Units are in seconds while data points are in ms.
Docker image version: jaegertracing/all-in-one:1.7