forked from marcelblijleven/goodwe
-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathbackup_mode2.dump
119 lines (119 loc) · 7.15 KB
/
backup_mode2.dump
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
timestamp: 2022-04-16 09:24:12 Timestamp
vpv1: 453.1 V PV1 Voltage
ipv1: 0.5 A PV1 Current
ppv1: 225 W PV1 Power
vpv2: 409.5 V PV2 Voltage
ipv2: 0.6 A PV2 Current
ppv2: 286 W PV2 Power
ppv: 511 W PV Power
pv2_mode: 2 PV2 Mode code
pv2_mode_label: PV panels connected, producing power PV2 Mode
pv1_mode: 2 PV1 Mode code
pv1_mode_label: PV panels connected, producing power PV1 Mode
vgrid: 241.6 V On-grid L1 Voltage
igrid: 1.0 A On-grid L1 Current
fgrid: 50.06 Hz On-grid L1 Frequency
pgrid: 184 W On-grid L1 Power
vgrid2: 240.2 V On-grid L2 Voltage
igrid2: 1.0 A On-grid L2 Current
fgrid2: 50.01 Hz On-grid L2 Frequency
pgrid2: 179 W On-grid L2 Power
vgrid3: 236.0 V On-grid L3 Voltage
igrid3: 1.1 A On-grid L3 Current
fgrid3: 49.95 Hz On-grid L3 Frequency
pgrid3: 191 W On-grid L3 Power
grid_mode: 1 Grid Mode code
grid_mode_label: Connected to grid Grid Mode
total_inverter_power: 556 W Total Power
active_power: -885 W Active Power
grid_in_out: 2 On-grid Mode code
grid_in_out_label: Importing On-grid Mode
reactive_power: 0 var Reactive Power
apparent_power: 0 VA Apparent Power
backup_v1: 240.1 V Back-up L1 Voltage
backup_i1: 0.3 A Back-up L1 Current
backup_f1: 50.06 Hz Back-up L1 Frequency
load_mode1: 1 Load Mode L1
backup_p1: 5 W Back-up L1 Power
backup_v2: 238.5 V Back-up L2 Voltage
backup_i2: 0.5 A Back-up L2 Current
backup_f2: 50.01 Hz Back-up L2 Frequency
load_mode2: 1 Load Mode L2
backup_p2: 3 W Back-up L2 Power
backup_v3: 235.1 V Back-up L3 Voltage
backup_i3: 0.6 A Back-up L3 Current
backup_f3: 49.95 Hz Back-up L3 Frequency
load_mode3: 1 Load Mode L3
backup_p3: 11 W Back-up L3 Power
load_p1: 51 W Load L1
load_p2: 23 W Load L2
load_p3: 1349 W Load L3
backup_ptotal: 18 W Back-up Load
load_ptotal: 1424 W Load
ups_load: 4 % Ups Load
temperature_air: 29.6 C Inverter Temperature (Air))
temperature_module: 0.0 C Inverter Temperature (Module)
temperature: 25.7 C Inverter Temperature (Radiator)
function_bit: 0 Function Bit
bus_voltage: 653.7 V Bus Voltage
nbus_voltage: 325.1 V NBus Voltage
vbattery1: 0.0 V Battery Voltage
ibattery1: 0.0 A Battery Current
pbattery1: 0 W Battery Power
battery_mode: 0 Battery Mode code
battery_mode_label: No battery Battery Mode
warning_code: 0 Warning code
safety_country: 13 Safety Country code
safety_country_label: Poland Safety Country
work_mode: 1 Work Mode code
work_mode_label: Normal (On-Grid) Work Mode
operation_mode: 0 Operation Mode code
error_codes: 0 Error Codes
errors: Errors
e_total: 1615.4 kWh Total PV Generation
e_day: 0.7 kWh Today's PV Generation
e_total_exp: 1694.5 kWh Total Energy (export)
h_total: 1921 h Hours Total
e_day_exp: 0.7 kWh Today Energy (export)
e_total_imp: 81.3 kWh Total Energy (import)
e_day_imp: 0.0 kWh Today Energy (import)
e_load_total: 1608.9 kWh Total Load
e_load_day: 1.3 kWh Today Load
e_bat_charge_total: 371.2 kWh Total Battery Charge
e_bat_charge_day: 0.0 kWh Today Battery Charge
e_bat_discharge_total: 305.8 kWh Total Battery Discharge
e_bat_discharge_day: 0.0 kWh Today Battery Discharge
diagnose_result: 34095279 Diag Status Code
diagnose_result_label: Battery voltage low, Battery SOC low, Battery SOC in back, BMS: Discharge disabled, Charge time on, BMS: Discharge current low, Battery Disconnected, Self-use off, PF value set Diag Status
house_consumption: 1396 W House Consumption
commode: 1 Commode
rssi: 101 RSSI
manufacture_code: 10 Manufacture Code
meter_test_status: 0 Meter Test Status
meter_comm_status: 1 Meter Communication Status
active_power1: 127 W Active Power L1
active_power2: 152 W Active Power L2
active_power3: -1166 W Active Power L3
active_power_total: -886 W Active Power Total
reactive_power_total: 208 var Reactive Power Total
meter_power_factor1: 0.505 Meter Power Factor L1
meter_power_factor2: 0.613 Meter Power Factor L2
meter_power_factor3: -0.988 Meter Power Factor L3
meter_power_factor: -0.527 Meter Power Factor
meter_freq: 50.01 Hz Meter Frequency
meter_e_total_exp: 973.557 kWh Meter Total Energy (export)
meter_e_total_imp: 305.538 kWh Meter Total Energy (import)
meter_active_power1: 127 W Meter Active Power L1
meter_active_power2: 152 W Meter Active Power L2
meter_active_power3: -1166 W Meter Active Power L3
meter_active_power_total: -886 W Meter Active Power Total
meter_reactive_power1: 205 var Meter Reactive Power L1
meter_reactive_power2: 178 var Meter Reactive Power L2
meter_reactive_power3: -175 var Meter Reactive Power L2
meter_reactive_power_total: 208 var Meter Reactive Power Total
meter_apparent_power1: 257 VA Meter Apparent Power L1
meter_apparent_power2: 250 VA Meter Apparent Power L2
meter_apparent_power3: -1180 VA Meter Apparent Power L3
meter_apparent_power_total: -1688 VA Meter Apparent Power Total
meter_type: 1 Meter Type
meter_sw_version: 5 Meter Software Version