Notifications
You must be signed in to change notification settings - Fork 484
/
flash.py
executable file
·197 lines (177 loc) · 6.82 KB
/
flash.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
#!/usr/bin/env python3
import bluepy
import sys
import time
import struct
import argparse
class Flash(object):
def __init__(self, doTest=False):
super().__init__()
self._doTest = doTest
self._firmware = None
self._device = None
self._miEnabled = False
self._customEnabled = False
def loadFirmware(self, firmware_name):
with open(firmware_name, "rb") as firmware_file:
firmware = firmware_file.read()
signature = struct.unpack(">L",firmware[8:12])[0]
if signature != 0x4b4e4c54:
print("The file is not a valid firmware file. Aborting.")
sys.exit(-1)
print(f"The firmware is {len(firmware)} bytes in length.")
while 0 != (len(firmware) % 16):
firmware += bytes([0xff])
self._firmware = firmware
self._blockCount = int(len(firmware) / 16)
print(f"Count: {int(self._blockCount)}")
def disconnect(self):
if not self._doTest:
self._device.disconnect()
def connect(self, mac):
if self._doTest:
return
else:
conTry = 0
maxTry = 5
self._device = bluepy.btle.Peripheral()
print(f"Trying to connect to {mac}")
while True:
conTry += 1
try:
self._device.connect(mac)
break
except bluepy.btle.BTLEException as ex:
if conTry <= maxTry:
print(f"{ex}, retrying: {conTry}/{maxTry}")
else:
print(f"{ex}")
self.disconnect()
sys.exit(-1)
print(f"Connected to {mac}")
services = self._device.getServices()
self._services = {}
for service in services:
self._services[str(service.uuid)] = service
if '00010203-0405-0607-0809-0a0b0c0d1912' in self._services:
service = self._services['00010203-0405-0607-0809-0a0b0c0d1912']
self._writeCharacteristic = service.getCharacteristics(forUUID='00010203-0405-0607-0809-0a0b0c0d2b12')[0]
self._detectMi()
else:
print("No Telink device detected.")
self.disconnect()
sys.exit(-1)
def _detectMi(self):
self._miEnabled = "ebe0ccb0-7a0a-4b0c-8a1a-6ff2997da3a6" in self._services
self._customEnabled = "00001f10-0000-1000-8000-00805f9b34fb" in self._services
if self._miEnabled:
print("Detected Mi Thermometer. Can't flash it.")
self.disconnect()
sys.exit(-1)
elif self._customEnabled:
print("Detected device with valid custom Firmware")
service = self._services['00001f10-0000-1000-8000-00805f9b34fb']
self._settingsCharacteristics = service.getCharacteristics(forUUID='00001f1f-0000-1000-8000-00805f9b34fb')[0]
else:
print("Detected device with not valid Firmware. Can't flash it.")
self.disconnect()
sys.exit(-1)
def startFlashing(self):
self._otaCharSend(bytes([0x00, 0xff]))
self._otaCharSend(bytes([0x01, 0xff]))
if self._doTest:
endline = "\n"
else:
endline = "\r"
for c in range(self._blockCount):
print(f"Sending block {c} of {self._blockCount} ({int(100 * c / self._blockCount)}%)", end=endline)
offset = c * 16
blockCount = struct.pack("<H", c)
block = self._firmware[offset:offset + 16]
crc = self._crc16_modbus(blockCount + block)
self._otaCharSend(blockCount + block + crc)
if ((c + 1) % 8) == 0:
if self._doTest:
print("Doing read")
else:
self._writeCharacteristic.read()
blockCount = self._blockCount - 1
blockCountInverted = 65535 - blockCount
data = struct.pack("<HHH",0xff02, blockCount, blockCountInverted)
self._otaCharSend(data)
print()
print("Done")
def _crc16_modbus(self, data):
crc = 0x0ffff
for d in data:
crc ^= struct.unpack("B", bytes([d]))[0]
for l in range(8):
odd = crc & 0x0001
crc = (crc >> 1) & 0x7fff
if odd != 0:
crc ^= 0xa001
return struct.pack("<H",crc)
def _otaCharSend(self, data):
if self._doTest:
for d in data:
d = hex(d)[2:]
if len(d) == 1:
d = '0' + d
print(d, end = "")
print()
else:
try:
self._writeCharacteristic.write(data)
except:
print("Failed to send data to the device. Aborting.")
self.disconnect()
sys.exit(-1)
def sendCustomSetting(self, data):
if self._doTest:
for d in data:
d = hex(d)[2:]
if len(d) == 1:
d = '0' + d
print(d, end = "")
print()
else:
try:
self._settingsCharacteristics.write(data)
except:
print(f"Error on sending setting 0x{data.hex()}")
self.disconnect()
sys.exit(-1)
print(f"Settings 0x{data.hex()} was send successful")
def waitForNotifications(self, timeout):
self._device.waitForNotifications(timeout)
def main(argv):
parser = argparse.ArgumentParser(description="Telink Flasher for Mi Thermostat")
group = parser.add_mutually_exclusive_group(required=True)
parser.add_argument("-t", "--test", dest="doTest", help="enable test mode", action="store_true")
group.add_argument("-f", "--firmware_file", help="firmware file to flash")
group.add_argument("-s", "--setting", help="custom settings strings to send")
parser.add_argument("mac", help="Mi Thermostat MAC address")
args = parser.parse_args()
manager = Flash(args.doTest)
manager.connect(args.mac)
if args.firmware_file:
manager.loadFirmware(args.firmware_file)
manager.startFlashing()
if args.setting:
try:
# convert "hex" string into an integer
setting = int(args.setting, 16)
# convert the integer into a bytearray
setting = setting.to_bytes(setting.bit_length() // 8, "big")
except:
print(f"Input '{args.setting}' is not a valid hex string")
manager.disconnect()
sys.exit(-1)
manager.sendCustomSetting(setting)
manager.disconnect()
if __name__ == "__main__":
try:
main(sys.argv[1:])
except Exception as exc:
sys.stderr.write("%s\n" % exc)
sys.exit(1)