Notifications
You must be signed in to change notification settings - Fork 174
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
[Documentation] Created a README.md for imaging_qc module (#5634)
Add README file for imaging_qc module.
- Loading branch information
1 parent
7e5a051
commit 66f9ce2
Showing
1 changed file
with
31 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,31 @@ | ||
## Imaging Quality Control Module | ||
|
||
#### Purpose | ||
The purpose of this module is to verify and help ensure imaging data has been uploaded into LORIS and reviewed for Quality Control (QC). It provides a queryable interface to check at a glance the completeness of imaging data collection for a study, and the status of QC review processes on them. | ||
|
||
Note: this module is not the module in which visual/radiological QC is performed on scans, just the module in which QC assessments are *reviewed*. Links are included in this module so the user can jump to the Imaging Browser to mark QC assessments on images and visits. | ||
|
||
#### Intended Users | ||
This module is used by study administrators, imaging scientists, analysts, coordinators, and clinicians. | ||
|
||
#### Scope | ||
The Imaging QC module allows you to view specific data on uploaded image files, with many additional filtering options. The resulting table has a column for QC status, so you can see whether the upload has passed QC or not. The table provides a link to each file. You can download the table in `.csv` format. | ||
|
||
Note: To QC a scan, the user must click the link leading to the Imaging Browser, and enter the QC details in that module. | ||
|
||
#### Configurations | ||
|
||
* This module will not load without the `mri_parameter_form` instrument installed and properly configured. Each scan type (identified below via the Configuration module) should have an equivalent _scan_done_ column in the database table for this instrument. | ||
> A sample MRI Parameter Form is available with our sample dataset in this repo: `raisinbread/instruments/NDB_BVL_Instrument_mri_parameter_form.class.inc`, and should be customized and installed for your project. (Please consult our online Setup Guide for more information.) | ||
* The `tblScanTypes` Configuration setting allows customization of which modalities are displayed in this module. | ||
|
||
#### Permissions | ||
The `quality_control` permission gives users access to this module and its features. | ||
|
||
#### Interactions With LORIS | ||
|
||
* Imaging Browser: presents info about and links to QC and scans, for the scan types specified in the Configuration module (as noted above) | ||
* Imaging Uploader : the name of the user who uploaded the scan is displayed in this module | ||
* Dicom Archive: Tarchive detected | ||
* MRI parameter form: Completeness of form and Scan Done are displayed, for this instrument |