diff --git a/scos_actions/actions/acquire_sea_data_product.py b/scos_actions/actions/acquire_sea_data_product.py index eba78255..e8190253 100644 --- a/scos_actions/actions/acquire_sea_data_product.py +++ b/scos_actions/actions/acquire_sea_data_product.py @@ -791,12 +791,23 @@ def capture_diagnostics(self, action_start_tic: float, cpu_speeds: list) -> None def set_ups_states(self, all_switch_status: dict, switch_diag: dict): if "ups_power_state" in all_switch_status: switch_diag["battery_backup"] = not all_switch_status["ups_power_state"] + else: + logger.warning("No ups_power_state found in switch status.") + if "ups_battery_level" in all_switch_status: switch_diag["low_battery"] = not all_switch_status["ups_battery_level"] + else: + logger.warning("No ups_battery_level found in switch status.") + if "ups_state" in all_switch_status: switch_diag["ups_healthy"] = not all_switch_status["ups_state"] + else: + logger.warning("No ups_state found in switch status.") + if "ups_battery_state" in all_switch_status: switch_diag["replace_battery"] = not all_switch_status["ups_battery_state"] + else: + logger.warning("No ups_battery_state found in switch status") def add_temperature_and_humidity_sensors( self, all_switch_status: dict, switch_diag: dict @@ -806,12 +817,15 @@ def add_temperature_and_humidity_sensors( switch_diag["temperature_sensors"].append( {"name": "internal_temp", "value": all_switch_status["internal_temp"]} ) + else: + logger.warning("No internal_temp found in switch status.") try: switch_diag["temperature_sensors"].append( {"name": "sigan_internal_temp", "value": self.sigan.temperature} ) except: logger.warning("Unable to read internal sigan temperature") + if "tec_intake_temp" in all_switch_status: switch_diag["temperature_sensors"].append( { @@ -819,6 +833,8 @@ def add_temperature_and_humidity_sensors( "value": all_switch_status["tec_intake_temp"], } ) + else: + logger.warning("No tec_intake_temp found in switch status.") if "tec_exhaust_temp" in all_switch_status: switch_diag["temperature_sensors"].append( @@ -827,6 +843,8 @@ def add_temperature_and_humidity_sensors( "value": all_switch_status["tec_exhaust_temp"], } ) + else: + logger.warning("No tec_exhaust_temp found in switch status.") if "internal_humidity" in all_switch_status: switch_diag["humidity_sensors"] = [ @@ -835,6 +853,8 @@ def add_temperature_and_humidity_sensors( "value": all_switch_status["internal_humidity"], } ] + else: + logger.warning("No internal_humidity found in switch status.") def add_power_sensors(self, all_switch_status: dict, switch_diag: dict): switch_diag["power_sensors"] = [] @@ -846,6 +866,9 @@ def add_power_sensors(self, all_switch_status: dict, switch_diag: dict): "expected_value": 5.0, } ) + else: + logger.warning("No power_monitor5v found in switch status") + if "power_monitor15v" in all_switch_status: switch_diag["power_sensors"].append( { @@ -854,6 +877,9 @@ def add_power_sensors(self, all_switch_status: dict, switch_diag: dict): "expected_value": 15.0, } ) + else: + logger.warning("No power_monitor15v found in switch status.") + if "power_monitor24v" in all_switch_status: switch_diag["power_sensors"].append( { @@ -862,6 +888,9 @@ def add_power_sensors(self, all_switch_status: dict, switch_diag: dict): "expected_value": 24.0, } ) + else: + logger.warning("No power_monitor24v found in switch status") + if "power_monitor28v" in all_switch_status: switch_diag["power_sensors"].append( { @@ -870,24 +899,39 @@ def add_power_sensors(self, all_switch_status: dict, switch_diag: dict): "expected_value": 28.0, } ) + else: + logger.warning("No power_monitor28v found in switch status") def add_heating_cooling(self, all_switch_status: dict, switch_diag: dict): if "heating" in all_switch_status: switch_diag["heating"] = all_switch_status["heating"] + else: + logger.warning("No heating found in switch status.") + if "cooling" in all_switch_status: switch_diag["cooling"] = all_switch_status["cooling"] + else: + logger.warning("No cooling found in switch status") def add_power_states(self, all_switch_status: dict, switch_diag: dict): if "sigan_powered" in all_switch_status: switch_diag["sigan_powered"] = all_switch_status["sigan_powered"] + else: + logger.warning("No sigan_powered found in switch status.") + if "temperature_control_powered" in all_switch_status: switch_diag["temperature_control_powered"] = all_switch_status[ "temperature_control_powered" ] + else: + logger.warning("No temperature_control_powered found in switch status.") + if "preselector_powered" in all_switch_status: switch_diag["preselector_powered"] = all_switch_status[ "preselector_powered" ] + else: + logger.warning("No preselector_powered found in switch status.") def create_global_sensor_metadata(self): # Add (minimal) ntia-sensor metadata to the sigmf_builder: