From 4525a644e0aaa91ecee33766cc5f7da1449ff894 Mon Sep 17 00:00:00 2001 From: Doug Boulware Date: Thu, 25 Apr 2024 20:45:52 -0600 Subject: [PATCH] Don't configure preselector and remove tektronix settings from metadata. --- scos_actions/actions/acquire_sea_data_product.py | 6 ++---- 1 file changed, 2 insertions(+), 4 deletions(-) diff --git a/scos_actions/actions/acquire_sea_data_product.py b/scos_actions/actions/acquire_sea_data_product.py index d7b54c99..7fbb3711 100644 --- a/scos_actions/actions/acquire_sea_data_product.py +++ b/scos_actions/actions/acquire_sea_data_product.py @@ -519,7 +519,7 @@ def __call__(self, sensor: Sensor, schedule_entry: dict, task_id: int): _ = psutil.cpu_percent(interval=None) # Initialize CPU usage monitor self.test_required_components() - self.configure_preselector(self.rf_path) + #self.configure_preselector(self.rf_path) # Initialize metadata object self.get_sigmf_builder( @@ -1155,9 +1155,7 @@ def create_capture_segment( reference=measurement_result["reference"], ), sigan_settings=ntia_sensor.SiganSettings( - reference_level=self.sensor.signal_analyzer.reference_level, - attenuation=self.sensor.signal_analyzer.attenuation, - preamp_enable=self.sensor.signal_analyzer.preamp_enable, + gain=self.sensor.signal_analyzer.gain ), ) if "compression_point" in measurement_result["applied_calibration"]: