Hello, thank you for your great work.
Since I need to automate target temperatures of the internal heating circuits,
I would like to be able to change also the following parameters:
14: Unknown(“ID_Einst_HzMK1E_akt")
774: Unknown(“ID_Einst_HzMK3E_akt")
Would you be so kind to help with that?
thank you
Ivo
Screenshot 2023-04-28 at 11 09 17

@BenPru
Copy link
Owner

BenPru commented Apr 30, 2023

Which type of heatpump do you have?
Do you know how I can detect the visibility of these values?
Please provide the following information about params 14-16 + 774-776:

  • min
  • max
  • step
  • Display name / description (english)

@02curls
Copy link
Author

02curls commented May 4, 2023

  1. I have got Alpha Innotec SWC 170H software version: V1.81.1
  2. no idea, but these new value triplets are I believe 100 % analogous to curently integrated values triplet 11,12,13, so if you know how to detect the visibility of values 11, 12, 13, it should be completely the same for these analogous values. In my system, the triplet 11,12,13 defines the heating curve of the core internal heating circuit (and the accumulation tank), the next analogous triplet 14,15,16 defines the heating curve of my first floor heating circuit, and the next one 774,775,776 defines the heating curve of my second floor heating,
  3. so
    11 and analogously 14, 774 (min:20 max:70 step:0,5 11name: luxtronik2_heating_circuit_curve1_temperature 14name: luxtronik2_heating_circuit2_curve1_temperature 774name: luxtronik2_heating_circuit3_curve1_temperature)
    12 and analogously 15, 775 (min:5 max:35 step:0,5 12name: luxtronik2_heating_circuit_curve2_temperature 15name: luxtronik2_heating_circuit2_curve2_temperature 775name: luxtronik2_heating_circuit3_curve2_temperature)
    13 and analogously 16, 776 (min:-15 max:10 step:0,5 13name: luxtronik2_heating_circuit_curve_night_temperature 16name: luxtronik2_heating_circuit2_curve_night_temperature 776name: luxtronik2_heating_circuit3_curve_night_temperature)

@02curls
Copy link
Author

02curls commented Sep 7, 2023

Hello, shall I provide more information or provide above information in a different, better usable/understandable way? thank you for your great work.

@rhammen
Copy link
Contributor

rhammen commented Sep 8, 2023

Have you tried using:
Service: "Luxtronik: write"
with
Service data:
parameter: ID_Einst_HzMK1E_akt
value: X
(With X being the value you want to set)

@rhammen
Copy link
Contributor

rhammen commented Sep 8, 2023

If the problem is that you are not allowed to write to that specific parameter:
you can overrule that, but you are ON YOUR OWN!
See section on https://github.com/Bouni/python-luxtronik about writing parameters.

UNTESTED:
I would expect that if you change line 43 in /custom_components/luxtronik2/const.py to:
CONF_SAFE: Final = False
that you can write all parameters from the Luxtronik integration.

Again: be careful, you are on your own when disabling the safeguard mechanism.

@02curls
Copy link
Author

02curls commented Sep 18, 2023

I am a mere HA user, I was able to set up all integrations that I needed with the HA yamls and automations GUIs, but python is above my capabilities,

also, is what you suggested above still possible? - #129

also, I believe I am not the only one with more than one heating circuit in the house, so implementing entities 14 and 774 into the integration would benefit more users?

@Kars-de-Jong
Copy link
Contributor

Kars-de-Jong commented Sep 19, 2023

You should probably first get these supported in https://github.com/Bouni/python-luxtronik, since they are now Unknown and thus do not have the correct data type and scaling.

Probably it's enough to change Unknown to Celsius, and add an extra True-parameter. similar to parameters 11, 12 and 13.

@02curls
Copy link
Author

02curls commented Sep 19, 2023

@Kars-de-Jong thank you! done that Bouni/python-luxtronik#137
seems OK?

@Kars-de-Jong
Copy link
Contributor

Yes, looks fine, although you might as well have included the ones for mixing circuit 2 as well.

@02curls
Copy link
Author

02curls commented Sep 28, 2023

@Kars-de-Jong yeah, sorry,
got the pull request approved Bouni/python-luxtronik#137
what can I do now to get them parameters included in BenPru's HA Luxtronic integration?
thank you

@02curls
Copy link
Author

02curls commented Sep 29, 2023

@Kars-de-Jong I believe the pull request including the mixing circuit 2 parameters has been approved and merged,
what can I do now to get them parameters included in BenPru's HA Luxtronic integration?
thank you

@Kars-de-Jong
Copy link
Contributor

@02curls You will have to wait until a new version of python-luxtronik is released which includes these changes, upgrade the requirement to at least that version and then you can use them here as well.

@BenPru
Copy link
Owner

BenPru commented Oct 14, 2023

@02curls Added to main branch. Release comes later.

@BenPru
Copy link
Owner

BenPru commented Oct 16, 2023

See 2023.10.16-Beta

@02curls
Copy link
Author

02curls commented Oct 17, 2023

tested, works, thank you!