Notifications
You must be signed in to change notification settings - Fork 670
/
Copy pathfast-reboot
executable file
·821 lines (711 loc) · 27.7 KB
/
fast-reboot
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
#!/bin/bash -e
REBOOT_USER=$(logname)
REBOOT_TIME=$(date)
REBOOT_CAUSE_FILE="/host/reboot-cause/reboot-cause.txt"
WARM_DIR=/host/warmboot
REDIS_FILE=dump.rdb
CONFIG_DB_FILE=/etc/sonic/config_db.json
REBOOT_SCRIPT_NAME=$(basename $0)
REBOOT_TYPE="${REBOOT_SCRIPT_NAME}"
SHUTDOWN_ORDER_FILE="/etc/sonic/${REBOOT_TYPE}_order"
VERBOSE=no
FORCE=no
IGNORE_ASIC=no
IGNORE_DB_CHECK=no
STRICT=no
REBOOT_METHOD="/sbin/kexec -e"
ASSISTANT_IP_LIST=""
ASSISTANT_SCRIPT="/usr/local/bin/neighbor_advertiser"
WATCHDOG_UTIL="/usr/local/bin/watchdogutil"
DEVPATH="/usr/share/sonic/device"
PLATFORM=$(sonic-cfggen -H -v DEVICE_METADATA.localhost.platform)
PLATFORM_PLUGIN="${REBOOT_TYPE}_plugin"
LOG_SSD_HEALTH="/usr/local/bin/log_ssd_health"
PLATFORM_FWUTIL_AU_REBOOT_HANDLE="platform_fw_au_reboot_handle"
SSD_FW_UPDATE="ssd-fw-upgrade"
TAG_LATEST=yes
DETACH=no
LOG_PATH="/var/log/${REBOOT_TYPE}.txt"
UIMAGE_HDR_SIZE=64
# Require 100M available on the hard drive for warm reboot temp files,
# Size is in 1K blocks:
MIN_HD_SPACE_NEEDED=100000
EXIT_SUCCESS=0
EXIT_FAILURE=1
EXIT_NOT_SUPPORTED=2
EXIT_FILE_SYSTEM_FULL=3
EXIT_NEXT_IMAGE_NOT_EXISTS=4
EXIT_ORCHAGENT_SHUTDOWN=10
EXIT_SYNCD_SHUTDOWN=11
EXIT_FAST_REBOOT_DUMP_FAILURE=12
EXIT_FILTER_FDB_ENTRIES_FAILURE=13
EXIT_COUNTERPOLL_DELAY_FAILURE=14
EXIT_DB_INTEGRITY_FAILURE=15
EXIT_NO_CONTROL_PLANE_ASSISTANT=20
EXIT_SONIC_INSTALLER_VERIFY_REBOOT=21
EXIT_PLATFORM_FW_AU_FAILURE=22
function error()
{
echo $@ >&2
}
function debug()
{
if [[ x"${VERBOSE}" == x"yes" ]]; then
echo $(date) $@
fi
logger "$@"
}
function showHelpAndExit()
{
echo "Usage: ${REBOOT_SCRIPT_NAME} [options]"
echo " -h,-? : get this help"
echo " -v : turn on verbose"
echo " -f : force execution - ignore Orchagent RESTARTCHECK failure"
echo " -i : force execution - ignore ASIC MD5-checksum-verification"
echo " -d : force execution - ignore database integrity check"
echo " -r : reboot with /sbin/reboot"
echo " -k : reboot with /sbin/kexec -e [default]"
echo " -x : execute script with -x flag"
echo " -c : specify control plane assistant IP list"
echo " -s : strict mode: do not proceed without:"
echo " - control plane assistant IP list."
echo " -t : Don't tag the current kube images as latest"
echo " -D : detached mode - closing terminal will not cause stopping reboot"
exit "${EXIT_SUCCESS}"
}
function parseOptions()
{
while getopts "vfidh?rkxc:sD" opt; do #TODO "t" is missing
case ${opt} in
h|\? )
showHelpAndExit
;;
v )
VERBOSE=yes
;;
f )
FORCE=yes
;;
i )
IGNORE_ASIC=yes
;;
d )
IGNORE_DB_CHECK=yes
;;
r )
REBOOT_METHOD="/sbin/reboot"
;;
k )
REBOOT_METHOD="/sbin/kexec -e"
;;
x )
set -x
;;
c )
ASSISTANT_IP_LIST=${OPTARG}
;;
s )
STRICT=yes
;;
t )
TAG_LATEST=no
;;
D )
DETACH=yes
;;
esac
done
}
function common_clear()
{
debug "${REBOOT_TYPE} failure ($?) cleanup ..."
/sbin/kexec -u || /bin/true
teardown_control_plane_assistant
}
function clear_fast_boot()
{
common_clear
sonic-db-cli STATE_DB DEL "FAST_REBOOT|system" &>/dev/null || /bin/true
}
function clear_warm_boot()
{
common_clear
result=$(timeout 10s config warm_restart disable; res=$?; if [[ $res == 124 ]]; then echo timeout; else echo "code ($res)"; fi) || /bin/true
debug "Cancel warm-reboot: ${result}"
TIMESTAMP=$(date +%Y%m%d-%H%M%S)
if [[ -f ${WARM_DIR}/${REDIS_FILE} ]]; then
mv -f ${WARM_DIR}/${REDIS_FILE} ${WARM_DIR}/${REDIS_FILE}.${TIMESTAMP} || /bin/true
fi
}
function init_warm_reboot_states()
{
# If the current running instance was booted up with warm reboot. Then
# the current DB contents will likely mark warm reboot is done.
# Clear these states so that the next boot up image won't get confused.
if [[ "$REBOOT_TYPE" = "warm-reboot" || "$REBOOT_TYPE" = "fastfast-reboot" ]]; then
sonic-db-cli STATE_DB eval "
for _, key in ipairs(redis.call('keys', 'WARM_RESTART_TABLE|*')) do
redis.call('hdel', key, 'state')
end
" 0 >/dev/null
fi
}
function initialize_pre_shutdown()
{
debug "Initialize pre-shutdown ..."
TABLE="WARM_RESTART_TABLE|warm-shutdown"
RESTORE_COUNT=$(sonic-db-cli STATE_DB hget "${TABLE}" restore_count)
if [[ -z "$RESTORE_COUNT" ]]; then
sonic-db-cli STATE_DB hset "${TABLE}" "restore_count" "0" > /dev/null
fi
sonic-db-cli STATE_DB hset "${TABLE}" "state" "requesting" > /dev/null
}
function request_pre_shutdown()
{
debug "Requesting pre-shutdown ..."
STATE=$(timeout 5s docker exec syncd /usr/bin/syncd_request_shutdown --pre &> /dev/null; if [[ $? == 124 ]]; then echo "timed out"; fi)
if [[ x"${STATE}" == x"timed out" ]]; then
error "Failed to request pre-shutdown"
fi
}
function recover_issu_bank_file()
{
debug "Recovering the (${ISSU_BANK_FILE}) file"
docker exec -i syncd sx_api_dbg_generate_dump.py
issu_bank_value=`docker exec -i syncd cat /tmp/sdkdump | grep 'ISSU Bank' | grep -o -E '[0-9]+'`
printf $issu_bank_value > /host/warmboot/issu_bank.txt
}
function check_issu_bank_file()
{
ISSU_BANK_FILE=/host/warmboot/issu_bank.txt
if [[ ! -s "$ISSU_BANK_FILE" ]]; then
error "(${ISSU_BANK_FILE}) does NOT exist or empty ..."
recover_issu_bank_file
return
fi
issu_file_chars_count=`stat -c %s ${ISSU_BANK_FILE}`;
issu_file_content=`awk '{print $0}' ${ISSU_BANK_FILE}`
if [[ $issu_file_chars_count != 1 ]] ||
[[ "$issu_file_content" != "0" && "$issu_file_content" != "1" ]]; then
error "(${ISSU_BANK_FILE}) is broken ..."
recover_issu_bank_file
fi
}
function wait_for_pre_shutdown_complete_or_fail()
{
debug "Waiting for pre-shutdown ..."
TABLE="WARM_RESTART_TABLE|warm-shutdown"
STATE="requesting"
declare -i waitcount
declare -i retrycount
retrycount=0
start_time=$SECONDS
elapsed_time=$(($SECONDS - $start_time))
# Wait up to 60 seconds for pre-shutdown to complete
while [[ ${elapsed_time} -lt 60 ]]; do
# timeout doesn't work with -i option of "docker exec". Therefore we have
# to invoke docker exec directly below.
STATE=$(timeout 5s sonic-db-cli STATE_DB hget "${TABLE}" state; if [[ $? == 124 ]]; then echo "timed out"; fi)
if [[ x"${STATE}" == x"timed out" ]]; then
retrycount+=1
debug "Timed out getting pre-shutdown state, retry count ${retrycount} ..."
if [[ retrycount -gt 2 ]]; then
break
fi
elif [[ x"${STATE}" != x"requesting" ]]; then
break
else
sleep 0.1
fi
elapsed_time=$(($SECONDS - $start_time))
done
if [[ x"${STATE}" != x"pre-shutdown-succeeded" ]]; then
debug "Syncd pre-shutdown failed, state: ${STATE} ..."
else
debug "Pre-shutdown succeeded, state: ${STATE} ..."
fi
}
function backup_database()
{
debug "Backing up database ..."
# Dump redis content to a file 'dump.rdb' in warmboot directory
mkdir -p $WARM_DIR
# Delete keys in stateDB except FDB_TABLE|*, MIRROR_SESSION_TABLE|*, WARM_RESTART_ENABLE_TABLE|*, FG_ROUTE_TABLE|*
sonic-db-cli STATE_DB eval "
for _, k in ipairs(redis.call('keys', '*')) do
if not string.match(k, 'FDB_TABLE|') and not string.match(k, 'WARM_RESTART_TABLE|') \
and not string.match(k, 'MIRROR_SESSION_TABLE|') \
and not string.match(k, 'FG_ROUTE_TABLE|') \
and not string.match(k, 'WARM_RESTART_ENABLE_TABLE|') \
and not string.match(k, 'VXLAN_TUNNEL_TABLE|') \
and not string.match(k, 'BUFFER_MAX_PARAM_TABLE|') then
redis.call('del', k)
end
end
" 0 > /dev/null
# move all db data into the instance where APPL_DB locates
target_db_inst=`centralize_database APPL_DB`
# Dump redis content to a file 'dump.rdb' in warmboot directory
docker cp database:/var/lib/$target_db_inst/$REDIS_FILE $WARM_DIR
STATE=$(timeout 5s docker exec database rm /var/lib/$target_db_inst/$REDIS_FILE; if [[ $? == 124 ]]; then echo "timed out"; fi)
if [[ x"${STATE}" == x"timed out" ]]; then
error "Timed out during attempting to remove Redis dump file from database container"
fi
}
function setup_control_plane_assistant()
{
if [[ -n "${ASSISTANT_IP_LIST}" && -x ${ASSISTANT_SCRIPT} ]]; then
# TH3 HW is not capable of VxLAN programming thus skipping TH3 platforms
if [[ "${HWSKU}" != "DellEMC-Z9332f-M-O16C64" && "${HWSKU}" != "DellEMC-Z9332f-M-O16C64-lab" ]]; then
debug "Setting up control plane assistant: ${ASSISTANT_IP_LIST} ..."
${ASSISTANT_SCRIPT} -s ${ASSISTANT_IP_LIST} -m set
else
debug "${HWSKU} Not capable to support CPA. Skipping gracefully ..."
fi
elif [[ X"${STRICT}" == X"yes" ]]; then
debug "Strict mode: fail due to lack of control plane assistant ..."
exit ${EXIT_NO_CONTROL_PLANE_ASSISTANT}
fi
}
function teardown_control_plane_assistant()
{
if [[ -n "${ASSISTANT_IP_LIST}" && -x ${ASSISTANT_SCRIPT} ]]; then
# TH3 HW is not capable of VxLAN programming thus skipping TH3 platforms
if [[ "${HWSKU}" != "DellEMC-Z9332f-M-O16C64" && "${HWSKU}" != "DellEMC-Z9332f-M-O16C64-lab" ]]; then
debug "Tearing down control plane assistant: ${ASSISTANT_IP_LIST} ..."
${ASSISTANT_SCRIPT} -s ${ASSISTANT_IP_LIST} -m reset
fi
fi
}
function is_secureboot() {
grep -Eq 'secure_boot_enable=[1y]' /proc/cmdline
}
function setup_reboot_variables()
{
# Kernel and initrd image
HWSKU=$(show platform summary --json | python -c 'import sys, json; print(json.load(sys.stdin)["hwsku"])')
NEXT_SONIC_IMAGE=$(sonic-installer list | grep "Next: " | cut -d ' ' -f 2)
IMAGE_PATH="/host/image-${NEXT_SONIC_IMAGE#SONiC-OS-}"
if grep -q aboot_platform= /host/machine.conf; then
if is_secureboot; then
KERNEL_IMAGE=""
BOOT_OPTIONS="SONIC_BOOT_TYPE=${BOOT_TYPE_ARG} secure_boot_enable=1"
else
KERNEL_IMAGE="$(ls $IMAGE_PATH/boot/vmlinuz-*)"
BOOT_OPTIONS="$(cat "$IMAGE_PATH/kernel-cmdline" | tr '\n' ' ') SONIC_BOOT_TYPE=${BOOT_TYPE_ARG}"
fi
INITRD=$(echo $KERNEL_IMAGE | sed 's/vmlinuz/initrd.img/g')
elif grep -q onie_platform= /host/machine.conf; then
if [ -r /host/grub/grub.cfg ]; then
KERNEL_OPTIONS=$(cat /host/grub/grub.cfg | sed "/$NEXT_SONIC_IMAGE'/,/}/"'!'"g" | grep linux)
KERNEL_IMAGE="/host$(echo $KERNEL_OPTIONS | cut -d ' ' -f 2)"
BOOT_OPTIONS="$(echo $KERNEL_OPTIONS | sed -e 's/\s*linux\s*/BOOT_IMAGE=/') SONIC_BOOT_TYPE=${BOOT_TYPE_ARG}"
INITRD=$(echo $KERNEL_IMAGE | sed 's/vmlinuz/initrd.img/g')
# Handle architectures supporting Device Tree
elif [ -f /sys/firmware/devicetree/base/chosen/bootargs ]; then
KERNEL_IMAGE="$(ls $IMAGE_PATH/boot/vmlinuz-*)"
BOOT_OPTIONS="$(cat /sys/firmware/devicetree/base/chosen/bootargs | sed 's/.$//') SONIC_BOOT_TYPE=${BOOT_TYPE_ARG}"
INITRD=$(echo $KERNEL_IMAGE | sed 's/vmlinuz/initrd.img/g')
# If initrd is a U-Boot uImage, remove the uImage header
if file ${INITRD} | grep -q uImage; then
INITRD_RAW=$(echo $KERNEL_IMAGE | sed 's/vmlinuz/initrd-raw.img/g')
tail -c+$((${UIMAGE_HDR_SIZE}+1)) < ${INITRD} > ${INITRD_RAW}
INITRD=${INITRD_RAW}
fi
else
error "Unknown ONIE platform bootloader. ${REBOOT_TYPE} is not supported."
exit "${EXIT_NOT_SUPPORTED}"
fi
else
error "Unknown bootloader. ${REBOOT_TYPE} is not supported."
exit "${EXIT_NOT_SUPPORTED}"
fi
}
function check_docker_exec()
{
containers="radv bgp lldp swss database teamd syncd"
for container in $containers; do
STATE=$(timeout 1s docker exec $container echo "success"; if [[ $? == 124 ]]; then echo "timed out"; fi)
if [[ x"${STATE}" == x"timed out" ]]; then
error "Docker exec on $container timedout"
exit "${EXIT_FAILURE}"
fi
done
}
function check_db_integrity()
{
if [[ "$REBOOT_TYPE" = "warm-reboot" || "$REBOOT_TYPE" = "fastfast-reboot" ]]; then
CHECK_DB_INTEGRITY=0
/usr/local/bin/check_db_integrity.py || CHECK_DB_INTEGRITY=$?
if [[ CHECK_DB_INTEGRITY -ne 0 ]]; then
if [[ x"${IGNORE_DB_CHECK}" == x"yes" ]]; then
debug "Ignoring Database integrity checks..."
else
error "Failed to validate DB's integrity. Exit code: ${CHECK_DB_INTEGRITY}. \
Use '-d' option to force ignore this check."
exit ${EXIT_DB_INTEGRITY_FAILURE}
fi
fi
fi
}
function reboot_pre_check()
{
check_docker_exec
# Make sure that the file system is normal: read-write able
filename="/host/test-$(date +%Y%m%d-%H%M%S)"
if [[ ! -f ${filename} ]]; then
touch ${filename}
fi
rm ${filename}
check_db_integrity
# Make sure /host has enough space for warm reboot temp files
avail=$(df -k /host | tail -1 | awk '{ print $4 }')
if [[ ${avail} -lt ${MIN_HD_SPACE_NEEDED} ]]; then
debug "/host has ${avail}K bytes available, not enough for warm reboot."
exit ${EXIT_FILE_SYSTEM_FULL}
fi
# Verify the next image by sonic-installer
INSTALLER_VERIFY_RC=0
sonic-installer verify-next-image > /dev/null || INSTALLER_VERIFY_RC=$?
if [[ INSTALLER_VERIFY_RC -ne 0 ]]; then
error "Failed to verify next image. Exit code: $INSTALLER_VERIFY_RC"
exit ${EXIT_SONIC_INSTALLER_VERIFY_REBOOT}
fi
# Make sure ASIC configuration has not changed between images
ASIC_CONFIG_CHECK_SCRIPT="/usr/local/bin/asic_config_check"
ASIC_CONFIG_CHECK_SUCCESS=0
if [[ "$REBOOT_TYPE" = "warm-reboot" || "$REBOOT_TYPE" = "fastfast-reboot" ]]; then
ASIC_CONFIG_CHECK_EXIT_CODE=0
${ASIC_CONFIG_CHECK_SCRIPT} || ASIC_CONFIG_CHECK_EXIT_CODE=$?
if [[ "${ASIC_CONFIG_CHECK_EXIT_CODE}" != "${ASIC_CONFIG_CHECK_SUCCESS}" ]]; then
if [[ x"${IGNORE_ASIC}" == x"yes" ]]; then
debug "Ignoring ASIC config checksum failure..."
else
error "ASIC config may have changed: errno=${ASIC_CONFIG_CHECK_EXIT_CODE}"
exit "${EXIT_FAILURE}"
fi
fi
fi
}
function load_aboot_secureboot_kernel() {
local next_image="$IMAGE_PATH/sonic.swi"
echo "Loading next image from $next_image"
unzip -qp "$next_image" boot0 | \
swipath=$next_image kexec=true loadonly=true ENV_EXTRA_CMDLINE="$BOOT_OPTIONS" bash -
}
function load_kernel() {
# Load kernel into the memory
/sbin/kexec -l "$KERNEL_IMAGE" --initrd="$INITRD" --append="$BOOT_OPTIONS"
}
function unload_kernel()
{
# Unload the previously loaded kernel if any loaded
if [[ "$(cat /sys/kernel/kexec_loaded)" -eq 1 ]]; then
/sbin/kexec -u
fi
}
function save_counters_folder() {
debug "Saving counters folder before warmboot..."
counters_folder="/host/counters"
if [[ ! -d $counters_folder ]]; then
mkdir $counters_folder
fi
if [[ "$REBOOT_TYPE" = "warm-reboot" || "$REBOOT_TYPE" = "fastfast-reboot" ]]; then
modules=("portstat-0" "dropstat" "pfcstat-0" "queuestat-0" "intfstat-0")
for module in ${modules[@]}
do
statfile="/tmp/$module"
if [[ -d $statfile ]]; then
cp -rf $statfile $counters_folder
fi
done
fi
}
function check_warm_restart_in_progress() {
sonic-db-cli STATE_DB keys "WARM_RESTART_ENABLE_TABLE|*" | while read key ; do
if [ -n "$key" ] && [[ x"$(sonic-db-cli STATE_DB hget $key enable)" == x"true" ]]; then
if [[ x"${FORCE}" == x"yes" ]]; then
debug "Ignoring warm restart flag for ${key#*|}"
else
echo "Warm restart flag for ${key#*|} is set. Please check if a warm restart for ${key#*|} is in progress."
exit "${EXIT_FAILURE}"
fi
fi
done
}
function check_conflict_boot_in_fw_update() {
# Make sure firmware auto update is not scheduled for a different reboot
FIRMWARE_AU_STATUS_DIR="/tmp/firmwareupdate"
FW_AU_TASK_FILE_REGEX="${FIRMWARE_AU_STATUS_DIR}/*_fw_au_task"
case "$REBOOT_TYPE" in
"fast-reboot")
FW_AU_TASK_FILE_EXP="${FIRMWARE_AU_STATUS_DIR}/fast_fw_au_task"
;;
"warm-reboot")
FW_AU_TASK_FILE_EXP="${FIRMWARE_AU_STATUS_DIR}/warm_fw_au_task"
;;
esac
FW_AU_TASK_FILE=$(compgen -G ${FW_AU_TASK_FILE_REGEX}) || true
if [[ -n "${FW_AU_TASK_FILE}" ]] && [[ ! -f "${FW_AU_TASK_FILE_EXP}" ]]; then
error "Firmware auto update scheduled for a different reboot: ${FW_AU_TASK_FILE}"
exit "${EXIT_FAILURE}"
fi
}
# main starts here
parseOptions $@
# Check root privileges
if [[ "$EUID" -ne 0 ]]
then
echo "This command must be run as root" >&2
exit "${EXIT_FAILURE}"
fi
# re-run the script in background mode with detaching from the terminal session
if [[ x"${DETACH}" == x"yes" && x"${ALREADY_DETACHED}" == x"" ]]; then
echo "Detaching the process from the terminal session. Redirecting output to ${LOG_PATH}."
ALREADY_DETACHED=yes $0 "$@" &>$LOG_PATH & disown %%
exit $?
fi
check_conflict_boot_in_fw_update
sonic_asic_type=$(sonic-cfggen -y /etc/sonic/sonic_version.yml -v asic_type)
# Check reboot type supported
BOOT_TYPE_ARG="cold"
case "$REBOOT_TYPE" in
"fast-reboot")
BOOT_TYPE_ARG=$REBOOT_TYPE
trap clear_fast_boot EXIT HUP INT QUIT TERM KILL ABRT ALRM
sonic-db-cli STATE_DB SET "FAST_REBOOT|system" "1" "EX" "180" &>/dev/null
;;
"warm-reboot")
check_warm_restart_in_progress
if [[ "$sonic_asic_type" == "mellanox" ]]; then
REBOOT_TYPE="fastfast-reboot"
BOOT_TYPE_ARG="fastfast"
# source mlnx-ffb.sh file with
# functions to check ISSU upgrade possibility
source mlnx-ffb.sh
else
BOOT_TYPE_ARG="warm"
fi
trap clear_warm_boot EXIT HUP INT QUIT TERM KILL ABRT ALRM
config warm_restart enable system
;;
*)
error "Not supported reboot type: $REBOOT_TYPE"
exit "${EXIT_NOT_SUPPORTED}"
;;
esac
save_counters_folder
unload_kernel
setup_reboot_variables
reboot_pre_check
if test -f /usr/local/bin/ctrmgr_tools.py
then
if [[ x"${TAG_LATEST}" == x"yes" ]]; then
/usr/local/bin/ctrmgr_tools.py tag-all
fi
fi
# Install new FW for mellanox platforms before control plane goes down
# So on boot switch will not spend time to upgrade FW increasing the CP downtime
if [[ "$sonic_asic_type" == "mellanox" ]]; then
MLNX_EXIT_SUCCESS=0
MLNX_EXIT_FW_ERROR=100
MLNX_EXIT_FFB_FAILURE=101
MLNX_FW_UPGRADE_SCRIPT="/usr/bin/mlnx-fw-upgrade.sh"
if [[ "$REBOOT_TYPE" = "fastfast-reboot" ]]; then
check_ffb || {
error "Warm reboot is not supported"
exit "${MLNX_EXIT_FFB_FAILURE}"
}
fi
debug "Prepare MLNX ASIC to ${REBOOT_TYPE}: install new FW if required"
${MLNX_FW_UPGRADE_SCRIPT} --upgrade
MLNX_EXIT_CODE="$?"
if [[ "${MLNX_EXIT_CODE}" != "${MLNX_EXIT_SUCCESS}" ]]; then
error "Failed to burn MLNX FW: errno=${MLNX_EXIT_CODE}"
exit "${MLNX_EXIT_FW_ERROR}"
fi
fi
if is_secureboot && grep -q aboot_machine= /host/machine.conf; then
load_aboot_secureboot_kernel
else
load_kernel
fi
if [[ "$REBOOT_TYPE" = "fast-reboot" ]]; then
# Dump the ARP and FDB tables to files also as default routes for both IPv4 and IPv6
# into /host/fast-reboot
DUMP_DIR=/host/fast-reboot
mkdir -p $DUMP_DIR
FAST_REBOOT_DUMP_RC=0
/usr/local/bin/fast-reboot-dump.py -t $DUMP_DIR || FAST_REBOOT_DUMP_RC=$?
if [[ FAST_REBOOT_DUMP_RC -ne 0 ]]; then
error "Failed to run fast-reboot-dump.py. Exit code: $FAST_REBOOT_DUMP_RC"
unload_kernel
exit "${EXIT_FAST_REBOOT_DUMP_FAILURE}"
fi
FILTER_FDB_ENTRIES_RC=0
# Filter FDB entries using MAC addresses from ARP table
/usr/local/bin/filter_fdb_entries -f $DUMP_DIR/fdb.json -a $DUMP_DIR/arp.json -c $CONFIG_DB_FILE || FILTER_FDB_ENTRIES_RC=$?
if [[ FILTER_FDB_ENTRIES_RC -ne 0 ]]; then
error "Failed to filter FDb entries. Exit code: $FILTER_FDB_ENTRIES_RC"
unload_kernel
exit "${EXIT_FILTER_FDB_ENTRIES_FAILURE}"
fi
fi
init_warm_reboot_states
setup_control_plane_assistant
if [[ "$REBOOT_TYPE" = "warm-reboot" || "$REBOOT_TYPE" = "fastfast-reboot" ]]; then
# Freeze orchagent for warm restart
# Ask orchagent_restart_check to try freeze 5 times with interval of 2 seconds,
# it is possible that the orchagent is in transient state and no opportunity to freeze
# Note: assume that 2*5 seconds is enough for orchagent to process the request and response to freeze or not
debug "Pausing orchagent ..."
docker exec -i swss /usr/bin/orchagent_restart_check -w 2000 -r 5 > /dev/null || RESTARTCHECK_RC=$?
if [[ RESTARTCHECK_RC -ne 0 ]]; then
error "RESTARTCHECK failed"
if [[ x"${FORCE}" == x"yes" ]]; then
debug "Ignoring orchagent pausing failure ..."
else
exit "${EXIT_ORCHAGENT_SHUTDOWN}"
fi
fi
fi
if [[ "$REBOOT_TYPE" = "fast-reboot" ]]; then
COUNTERPOLL_DELAY_RC=0
# Delay counters in config_db.json
/usr/local/bin/counterpoll config-db delay $CONFIG_DB_FILE || COUNTERPOLL_DELAY_RC=$?
if [[ COUNTERPOLL_DELAY_RC -ne 0 ]]; then
error "Failed to delay counterpoll. Exit code: $COUNTERPOLL_DELAY_RC"
unload_kernel
exit "${EXIT_COUNTERPOLL_DELAY_FAILURE}"
fi
fi
# We are fully committed to reboot from this point on because critical
# service will go down and we cannot recover from it.
set +e
# disable trap-handlers which were set before
trap '' EXIT HUP INT QUIT TERM KILL ABRT ALRM
if [ -x ${LOG_SSD_HEALTH} ]; then
debug "Collecting logs to check ssd health before ${REBOOT_TYPE}..."
${LOG_SSD_HEALTH}
fi
if [[ -f ${SHUTDOWN_ORDER_FILE} ]]; then
SERVICES_TO_STOP="$(cat ${SHUTDOWN_ORDER_FILE})"
else
# TODO: to be removed once sonic-buildimage change is in
if [[ "${REBOOT_TYPE}" == "fast-reboot" ]]; then
SERVICES_TO_STOP="nat radv bgp sflow lldp swss teamd syncd"
elif [[ "${REBOOT_TYPE}" == "fastfast-reboot" || "${REBOOT_TYPE}" == "warm-reboot" ]]; then
SERVICES_TO_STOP="nat radv bgp sflow lldp teamd swss syncd"
else
error "Unexpected reboot type ${REBOOT_TYPE}"
exit $EXIT_FAILURE
fi
fi
for service in ${SERVICES_TO_STOP}; do
debug "Stopping ${service} ..."
# TODO: These exceptions for nat, sflow, lldp
# have to be coded in corresponding service scripts
if [[ "${service}" = "nat" ]]; then
/usr/local/bin/dump_nat_entries.py
fi
if [[ "${service}" = "nat" || "${service}" = "sflow" || "${service}" = "lldp" ]]; then
container kill "${service}" &> /dev/null || debug "Docker ${service} is not running ($?) ..."
fi
if [[ "${service}" = "syncd" ]]; then
systemctl stop ${service} || debug "Ignore stopping ${service} service error $?"
else
systemctl stop ${service}
fi
debug "Stopped ${service}"
if [[ "${service}" = "swss" ]]; then
if [[ "$REBOOT_TYPE" = "warm-reboot" || "$REBOOT_TYPE" = "fastfast-reboot" ]]; then
# Pre-shutdown syncd
initialize_pre_shutdown
if [[ "x$sonic_asic_type" == x"mellanox" ]]; then
check_issu_bank_file
fi
request_pre_shutdown
wait_for_pre_shutdown_complete_or_fail
if [[ "x$sonic_asic_type" == x"mellanox" ]]; then
check_issu_bank_file
fi
# Warm reboot: dump state to host disk
if [[ "$REBOOT_TYPE" = "fastfast-reboot" ]]; then
sonic-db-cli ASIC_DB FLUSHDB > /dev/null
sonic-db-cli COUNTERS_DB FLUSHDB > /dev/null
sonic-db-cli FLEX_COUNTER_DB FLUSHDB > /dev/null
fi
# TODO: backup_database preserves FDB_TABLE
# need to cleanup as well for fastfast boot case
backup_database
fi
fi
done
# Kill other containers to make the reboot faster
# We call `docker kill ...` to ensure the container stops as quickly as possible,
# then immediately call `systemctl stop ...` to prevent the service from
# restarting the container automatically.
debug "Stopping all remaining containers ..."
if test -f /usr/local/bin/ctrmgr_tools.py
then
/usr/local/bin/ctrmgr_tools.py kill-all
else
for CONTAINER_NAME in $(docker ps --format '{{.Names}}'); do
CONTAINER_STOP_RC=0
docker kill $CONTAINER_NAME &> /dev/null || CONTAINER_STOP_RC=$?
systemctl stop $CONTAINER_NAME || debug "Ignore stopping $CONTAINER_NAME error $?"
if [[ CONTAINER_STOP_RC -ne 0 ]]; then
debug "Failed killing container $CONTAINER_NAME RC $CONTAINER_STOP_RC ."
fi
done
fi
debug "Stopped all remaining containers ..."
# Stop the docker container engine. Otherwise we will have a broken docker storage
systemctl stop docker.service || debug "Ignore stopping docker service error $?"
# Stop kernel modules for Nephos platform
if [[ "$sonic_asic_type" = 'nephos' ]];
then
systemctl stop nps-modules-`uname -r`.service || debug "Ignore stopping nps service error $?"
fi
# Stop opennsl modules for Broadcom platform
if [[ "$sonic_asic_type" = 'broadcom' ]];
then
service_name=$(systemctl list-units --plain --no-pager --no-legend --type=service | grep opennsl | cut -f 1 -d' ')
systemctl stop "$service_name"
fi
# Update the reboot cause file to reflect that user issued this script
# Upon next boot, the contents of this file will be used to determine the
# cause of the previous reboot
echo "User issued '${REBOOT_SCRIPT_NAME}' command [User: ${REBOOT_USER}, Time: ${REBOOT_TIME}]" > ${REBOOT_CAUSE_FILE}
# Wait until all buffers synced with disk
sync
sleep 1
sync
# sync the current system time to CMOS
if [ -x /sbin/hwclock ]; then
/sbin/hwclock -w || /bin/true
fi
if [[ -x ${DEVPATH}/${PLATFORM}/${PLATFORM_FWUTIL_AU_REBOOT_HANDLE} ]]; then
debug "Handling task file for boot type ${REBOOT_TYPE}"
${DEVPATH}/${PLATFORM}/${PLATFORM_FWUTIL_AU_REBOOT_HANDLE} ${REBOOT_TYPE} || PLATFORM_FW_AU_RC=$?
if [[ $PLATFORM_FW_AU_RC -ne 0 ]]; then
debug "ERROR: Failed to handle the platform firmware auto-update for ${REBOOT_TYPE} Exit code: $PLATFORM_FW_AU_RC"
exit "${EXIT_PLATFORM_FW_AU_FAILURE}"
fi
fi
# Enable Watchdog Timer
if [ -x ${WATCHDOG_UTIL} ]; then
debug "Enabling Watchdog before ${REBOOT_TYPE}"
${WATCHDOG_UTIL} arm
fi
# Run platform specific reboot plugin
if [ -x ${DEVPATH}/${PLATFORM}/${PLATFORM_PLUGIN} ]; then
debug "Running ${PLATFORM} specific plugin..."
${DEVPATH}/${PLATFORM}/${PLATFORM_PLUGIN}
fi
# Reboot: explicitly call Linux native reboot under sbin
debug "Rebooting with ${REBOOT_METHOD} to ${NEXT_SONIC_IMAGE} ..."
exec ${REBOOT_METHOD}
# Should never reach here
error "${REBOOT_TYPE} failed!"
exit "${EXIT_FAILURE}"